Seoul National University · Engineering
강승균 교수의 연구실은 생분해 가능한 전자소자를 중심으로, 생체 환경에서 안전하게 분해되는 '순환형 전자소재'와 '임시 기능성 전자장치'의 기초 소재 및 시스템 기술을 연구하고 있습니다. 특히 실리콘 산화물, 질화물, 게르마늄 및 생분해성 폴리머를 활용한 생체 적합성과 제어된 분해 특성을 확보하며 의료 임플란트, 환경 센서, 보안 장치 등에 적용 가능한 신개념 전자 기술을 개발하고 있습니다. 고성능 나노필름 공정과 물리화학적 분해 메커니즘 분석을 기반으로, 지속 가능한 전자기기의 실현 가능성을 탐색하고 있습니다.
Figures are computed from collected data and may differ slightly.
Silicon oxides and nitrides are key materials for dielectrics and encapsulation layers in a class of silicon‐based high performance electronics that has ability to completely dissolve in a controlled fashion with programmable rates, when submerged in bio‐fluids and/or relevant solutions. This type of technology, referred to as “transient electronics”, has potential applications in biomedical implants, environmental sensors, and other envisioned areas. The results presented here provide comprehen
Recent advances in materials chemistry establish the foundations for unusual classes of electronic systems, characterized by their ability to fully or partially dissolve, disintegrate, or otherwise physically or chemically decompose in a controlled fashion after some defined period of stable operation. Such types of "transient" technologies may enable consumer gadgets that minimize waste streams associated with disposal, implantable sensors that disappear harmlessly in the body, and hardware-sec
Semiconducting materials are central to the development of high-performance electronics that are capable of dissolving completely when immersed in aqueous solutions, groundwater, or biofluids, for applications in temporary biomedical implants, environmentally degradable sensors, and other systems. The results reported here include comprehensive studies of the dissolution by hydrolysis of polycrystalline silicon, amorphous silicon, silicon-germanium, and germanium in aqueous solutions of various
Biodegradable substrates and encapsulating materials play critical roles in the development of an emerging class of semiconductor technology, generally referred as “transient electronics”, whose key characteristic is an ability to dissolve completely, in a controlled manner, upon immersion in ground water or biofluids. The results presented here introduce the use of thin foils of Mo, Fe, W, or Zn as biodegradable substrates and silicate spin‐on‐glass (SOG) materials as insulating and encapsulati
Abstract Bioresorbable electronic systems represent an emerging class of technology of interest due to their ability to dissolve, chemically degrade, disintegrate, and/or otherwise physically disappear harmlessly in biological environments, as the basis for temporary implants that avoid the need for secondary surgical extraction procedures. Polyanhydride‐based polymers can serve as hydrophobic encapsulation layers for such systems, as a subset of the broader field of transient electronics, where
Transient electronics, which can be tuned to be completely or partially dissoluble, degradable, and disintegrable, create new opportunities in the upcoming ubiquitous electronics era that are inaccessible with conventional permanent electronics. This emerging field offers unique electronic applications in environmentally degradable eco-devices with minimal or zero waste, biodegradable medical implants not requiring secondary removal surgery, and hardware-based security devices with self-destruct
Real-time monitoring of infinitesimal deformations on complex morphologies is essential for precision biomechanical engineering. While flexible strain sensors facilitate real-time monitoring with shape-adaptive properties, their sensitivity is generally lower than spectroscopic imaging methods. Crack-based strain sensors achieve enhanced sensitivity with gauge factors (GFs) exceeding 30,000; however, such GFs are only attainable at large strains exceeding several percent and decline below 10 for
Abstract A fully biodegradable, ultra‐sensitive, and soft strain sensor is pivotal for temporary, real‐time monitoring of microdeformations, crucial in disease diagnosis, surgical precision, and prognosis of muscular, and vascular conditions. Nevertheless, the strain sensitivity of previous biodegradable sensors, denoted by gauge factor (GF) up to ≈100, falls short of requirements for complex biomedical monitoring scenarios, specifically monitoring cardio‐cerebrovascular diseases with microscale
Regeneration of over 10 mm long peripheral nerve defects remains a challenge due to the failure of regeneration by prolonged axotomy and denervation occurring in long-term recovery. Recent studies reveal that conductive conduits and electrical stimulation accelerate the regeneration of long nerve defects. In this study, an electroceutical platform combining a fully biodegradable conductive nerve conduit and a wireless electrical stimulator is proposed to maximize the therapeutic effect on nerve
Polymers with the shape memory effect possess tremendous potential for application in diverse fields, including aerospace, textiles, robotics, and biomedicine, because of their mechanical properties (softness and flexibility) and chemical tunability. Biodegradable shape memory polymers (BSMPs) have unique benefits of long-term biocompatibility and formation of zero-waste byproducts as the final degradable products are resorbed or absorbed via metabolism or enzyme digestion processes. In addition
Open papers in the app to read, cite, and organize with AI.