Skip to main content
QUICK REVIEW

[Paper Review] An upgraded ultra-high vacuum magnetron-sputtering system for high-versatility and software-controlled deposition

Arnaud le Febvrier, Ludvig Landälv|arXiv (Cornell University)|Oct 16, 2020
Metal and Thin Film MechanicsEngineering31 references86 citations
TL;DR

This paper presents an upgraded ultra-high vacuum (UHV) magnetron sputtering system designed for high versatility in depositing metallic, oxide, nitride, and oxynitride films. The system integrates software-controlled automation via custom LabVIEW software for precise, reproducible process control, including real-time logging, shutter timing, bias voltage application, and coil-enhanced plasma density, enabling complex multilayer and superlattice deposition with full parameter synchronization and programmable sequences through CSV-based layer definition.

ABSTRACT

Magnetron sputtering is a widely used physical vapor deposition technique. Reactive sputtering is used for the deposition of, e.g, oxides, nitrides and carbides. In fundamental research, versatility is essential when designing or upgrading a deposition chamber. Furthermore, automated deposition systems are the norm in industrial production, but relatively uncommon in laboratory-scale systems used primarily for fundamental research. Combining automatization and computerized control with the required versatility for fundamental research constitutes a challenge in designing, developing, and upgrading laboratory deposition systems. The present article provides a detailed description of the design of a lab-scale deposition chamber for magnetron sputtering used for the deposition of metallic, oxide, nitride and oxynitride films with automated controls, dc or pulsed bias, and combined with a coil to enhance the plasma density near the substrate. LabVIEW software (provided as Supplementary Information) has been developed for a high degree of computerized or automated control of hardware and processes control and logging of process details.

Motivation & Objective

  • To address the challenge of combining high versatility with automated, computerized control in lab-scale physical vapor deposition systems for fundamental research.
  • To enable precise, reproducible deposition of diverse materials—metallic, oxide, nitride, and oxynitride films—under UHV conditions.
  • To develop a software-controlled system capable of managing complex deposition sequences, including multilayers and superlattices, with synchronized control of shutters, bias, and plasma enhancement.
  • To provide a freely modifiable, open-source LabVIEW software framework for replication and adaptation in other deposition systems.

Proposed method

  • The system features a UHV chamber (base pressure < 3.9×10⁻⁷ Pa) made of low-carbon stainless steel, equipped with a load-lock for sample transfer.
  • Four magnetron sputtering sources support dc, rf, or pulsed-dc power, enabling deposition of various materials using Ar, O₂, and N₂ gases with mass flow controllers.
  • A substrate bias supply and an external coil are used to enhance plasma density and control ion bombardment energy during deposition.
  • A custom LabVIEW software interface enables real-time monitoring, logging, and automated control of all process parameters including pressure, gas flow, power, voltage, current, temperature, and arc counts.
  • Deposition sequences, including multilayers and superlattices, are programmed via a comma-separated values (CSV) file defining time, shutter status, bias, and coil settings per layer.
  • The system includes a quadrupole mass spectrometer for residual gas analysis and real-time monitoring of reactive gas partial pressures during deposition.

Experimental results

Research questions

  • RQ1How can a lab-scale magnetron sputtering system achieve high versatility in depositing metallic, oxide, nitride, and oxynitride films under ultra-high vacuum conditions?
  • RQ2What level of automation and process control can be achieved in a research-grade system using software-based control, and how does it improve reproducibility?
  • RQ3How does substrate rotation and coil-enhanced plasma density affect the uniformity and energy distribution of sputtered species on the substrate?
  • RQ4To what extent can a custom LabVIEW software framework enable complex deposition sequences such as multilayers and superlattices with synchronized control of multiple system components?
  • RQ5Can the integration of real-time logging and parameter synchronization significantly enhance experimental traceability and reproducibility in fundamental materials research?

Key findings

  • The system achieves a base pressure below 3.9×10⁻⁷ Pa after baking at 140 °C for 48 hours, ensuring high vacuum integrity.
  • Effective pumping speeds of up to 216 l/s were measured at 0.33 Pa (2.5 mTorr) argon pressure, minimizing hysteresis in reactive sputtering processes.
  • Substrate rotation reduces deposition inhomogeneity, with particle flux variation decreasing from 50% (non-rotating) to 9% (rotating) across the substrate zone.
  • The LabVIEW software enables real-time monitoring of up to six process variables simultaneously, with full data logging and automated control of shutters, bias, and coil power.
  • The use of a CSV-based layer definition file allows for unlimited layer sequences and complex parameter combinations, facilitating the deposition of multilayer and superlattice structures.
  • The system supports automated target cleaning procedures and synchronized control of multiple components with a 1-second waiting time to ensure timing accuracy across shutters and power supplies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.