Medical image segmentation plays a crucial role in advancing healthcare systems for disease diagnosis and treatment planning. The u-shaped architecture, popularly known as U-Net, has proven highly successful for various medical image segmentation tasks. However, U-Net's convolution-based operations inherently limit its ability to model long-range dependencies effectively. To address these limitations, researchers have turned to Transformers, renowned for their global self-attention mechanisms, as alternative architectures. One popular network is our previous TransUNet, which leverages Transformers' self-attention to complement U-Net's localized information with the global context. In this paper, we extend the 2D TransUNet architecture to a 3D network by building upon the state-of-the-art nnU-Net architecture, and fully exploring Transformers' potential in both the encoder and decoder design. We introduce two key components: 1) A Transformer encoder that tokenizes image patches from a convolution neural network (CNN) feature map, enabling the extraction of global contexts, and 2) A Transformer decoder that adaptively refines candidate regions by utilizing cross-attention between candidate proposals and U-Net features. Our investigations reveal that different medical tasks benefit from distinct architectural designs. The Transformer encoder excels in multi-organ segmentation, where the relationship among organs is crucial. On the other hand, the Transformer decoder proves more beneficial for dealing with small and challenging segmented targets such as tumor segmentation. Extensive experiments showcase the significant potential of integrating a Transformer-based encoder and decoder into the u-shaped medical image segmentation architecture. TransUNet outperforms competitors in various medical applications.
研究动机与目标
- 激发并解决卷积神经网络在建模 3D 医学图像分割中的长程依赖方面的局限性。
- 研究在类似 U-Net 的架构中将 Transformer 集成到编码器与解码器中的影响。
- 开发一个启用 Transformer 的三维分割框架,利用 CNN 特征实现高分辨率定位,利用 Transformer 提供全局上下文。
提出的方法
- 引入一个 Transformer 编码器,将 CNN 特征块进行标记化以提取全局上下文,同时保持来自 CNN 特征的高分辨率细节。
- 描述一个 Transformer 解码器,将分割视为掩模分类,使用可学习的器官查询,通过与多尺度 CNN 特征的交叉注意力进行细化。
- 在解码器中融入粗到细的注意力细化,以对小目标的前景区域进行渐进聚焦。
- 提供三种配置(仅编码器、仅解码器、编码器+解码器),以 3D nnU-Net 骨干为基础,使用匈牙利匹配损失进行训练。
- 使用混合损失(像素级交叉熵和 Dice)进行训练,并在解码器阶段进行深度监督。
- 证明与 2D 和 3D 数据的兼容性,并在若干医学分割基准上报告最新性能。
实验结果
研究问题
- RQ1在 3D 医学图像分割中,将视觉变换器集成到编码器与解码器中的影响是什么?
- RQ2混合 CNN-Transformer 架构是否能提升多器官任务与小目标病灶的分割性能?
- RQ3在 Transformer 解码器中采用粗到细的注意力细化是否能提高对具有挑战性的目标的分割准确性?
- RQ4不同配置(仅编码器、仅解码器、编码器+解码器)在多样的分割数据集上如何比较?
主要发现
- 仅编码器的设计在多器官分割中带来显著提升,因为更好地建模全局器官关系。
- 仅解码器的设计在小目标分割(如肿瘤)方面表现出色,通过可学习查询和跨注意力细化预测。
- 组合的编码器+解码器在各任务上并未始终超过最佳单分支设计,表明存在互补优势但可能存在重叠。
- 经过 Transformer 增强的编码器在多器官任务中 Dice 提升高达约 0.8%,解码器变体在评估数据集上使血管/肿瘤分割的 Dice 提升约 1.6%。
- 在 ImageNet21k 上使用 12 层 ViT 的预训练编码器变体为 3D 医学分割任务提供了强劲的性能提升。