Skip to main content
QUICK REVIEW

[论文解读] A DMD-Based Adaptive Modulation Method for High Dynamic Range Imaging in High-Glare Environments

Banglei Guan, Jing Tao|arXiv (Cornell University)|Feb 12, 2026
Advanced Optical Sensing TechnologiesPhysics and Astronomy被引用 1
一句话总结

这篇论文提出了一种基于DMD的自适应掩模光学调制系统,在强眩光场景下实现超过120 dB的HDR成像,从而实现高精度DIC并降低应变误差。

ABSTRACT

Background The accuracy of photomechanics measurements critically relies on image quality,particularly under extreme illumination conditions such as welding arc monitoring and polished metallic surface analysis. High dynamic range (HDR) imaging above 120 dB is essential in these contexts. Conventional CCD/CMOS sensors, with dynamic ranges typically below 70 dB, are highly susceptible to saturation under glare, resulting in irreversible loss of detail and significant errors in digital image correlation (DIC). Methods This paper presents an HDR imaging system that leverages the spatial modulation capability of a digital micromirror device (DMD). The system architecture enables autonomous regional segmentation and adaptive exposure control for high-dynamic-range scenes through an integrated framework comprising two synergistic subsystems: a DMD-based optical modulation unit and an adaptive computational imaging pipeline. Results The system achieves a measurable dynamic range of 127 dB, effectively eliminating satu ration artifacts under high glare. Experimental results demonstrate a 78% reduction in strain error and improved DIC positioning accuracy, confirming reliable performance across extreme intensity variations. Conclusion The DMD-based system provides high fidelity adaptive HDR imaging, overcoming key limitations of conventional sensors. It exhibits strong potential for optical metrology and stress analysis in high-glare environments where traditional methods are inadequate.

研究动机与目标

  • 在强眩光条件下解决HDR成像在光学计量中的饱和与细节损失

提出的方法

  • 开发一个由DMD光学调制单元和自适应计算成像流程组成的双子系统架构
  • 采用双透镜筒式光学设计以保持像素级精度并最小化畸变
  • 实现一个自适应掩模生成算法,能够在实时中迭代抑制饱和区域
  • 通过将基于DMD的空间调制与高动态范围sCMOS采集相结合来合成HDR辐射度
  • 通过将87 dB的sCMOS与40 dB的DMD调制耦合(Tmax/Tmin = 100)实现总可检测动态范围127 dB
  • 提供一个软件接口用于实时控制衰减、伽玛和增益

实验结果

研究问题

  • RQ1DMD自适应调制系统是否能够在极端眩光下消除传感器饱和,同时保留阴影和细节?
  • RQ2将DMD光学衰减与高动态范围传感器结合时可达到的可检测动态范围是多少?
  • RQ3与传统HDR和后处理方法相比,所提方法对DIC的准确性和鲁棒性有何影响?
  • RQ4系统是否能够在边缘区域和高对比度过渡处保持测量保真度?

主要发现

  • 实现了127 dB的可测动态范围,实质性地消除了高眩光下的饱和伪影
  • 相比传统成像,DIC测量中的应变误差减少78%
  • 在不同曝光水平下保持全场测量完整性,等效计算区域保持在100%
  • 在信息熵、对比度和感知质量指标上优于传统图像增强和硬件HDR方法
  • 在高对比度区域提供更好的DIC对准精度并减少空间收缩
  • 在静态和动态DIC测试中对极端照明具有鲁棒性

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。