Skip to main content
QUICK REVIEW

[论文解读] A wideband, high-resolution vector spectrum analyzer for integrated photonics

Yi-Han Luo, Baoqi Shi|arXiv (Cornell University)|Apr 9, 2023
Advanced Fiber Laser TechnologiesPhysics and Astronomy参考文献 1被引用 3
一句话总结

本文提出了一种基于光纤的超宽带矢量谱分析仪(VSA),带宽达55.1 THz,频率分辨率为471 kHz,动态范围为56 dB,可实现对集成光子器件和超宽带激光源的高分辨率表征。该系统利用啁啾连续波激光器,通过相位稳定的光纤腔作为参考,将光学频率响应相干映射至时域,利用拍频信号实现,无需高速调制器或主动反馈控制。

ABSTRACT

The analysis of optical spectra - emission or absorption -- has been arguably the most powerful approach for discovering and understanding matters. The invention and development of many kinds of spectrometers have equipped us with versatile yet ultra-sensitive diagnostic tools for trace gas detection, isotope analysis, and resolving hyperfine structures of atoms and molecules. With proliferating data and information, urgent and demanding requirements have been placed today on spectrum analysis with ever-increasing spectral bandwidth and frequency resolution. These requirements are especially stringent for broadband laser sources that carry massive information, and for dispersive devices used in information processing systems. In addition, spectrum analyzers are expected to probe the device's phase response where extra information is encoded. Here we demonstrate a novel vector spectrum analyzer (VSA) that is capable of characterizing passive devices and active laser sources in one setup. Such a dual-mode VSA can measure loss, phase response and dispersion properties of passive devices. It also can coherently map a broadband laser spectrum into the RF domain. The VSA features a bandwidth of 55.1 THz (1260 to 1640 nm), frequency resolution of 471 kHz, and dynamic range of 56 dB. Meanwhile, our fiber-based VSA is compact and robust. It requires neither high-speed modulators and photodetectors, nor any active feedback control. Finally, we successfully employ our VSA for applications including characterization of integrated dispersive waveguides, mapping frequency comb spectra, and coherent light detection and ranging (LiDAR). Our VSA presents an innovative approach for device analysis and laser spectroscopy, and can play a critical role in future photonic systems and applications for sensing, communication, imaging, and quantum information processing.

研究动机与目标

  • 开发一种高分辨率、超宽带矢量谱分析仪(VSA),用于表征集成光子学中被动与主动光子器件。
  • 克服传统光谱分析仪(OSA)和光矢量网络分析仪(OVNA)在光谱分辨率、带宽和相位响应测量方面的局限性。
  • 通过单一、坚固且可移动的系统,实现对宽带激光器的损耗、相位、色散及完整光谱轮廓的同步测量。
  • 在无需主动反馈或高速组件的情况下实现精确的频率校准,提升系统稳定性与现场部署能力。

提出的方法

  • 采用啁啾连续波(CW)激光器,通过拍频信号将被测器件(DUT)的频域传输函数相干映射至时域。
  • 利用自由光谱范围(FSR)为55.58 MHz的相位稳定光纤腔作为频率标准,精确校准啁啾过程中激光的瞬时频率。
  • 系统工作于双模式:作为OVNA测量被动器件的线性传输函数(LTF)和色散特性;作为OSA分析宽带频率梳光谱。
  • 通过示波器捕获光电探测器的时域波形,并利用互相关与参考腔校准实现光谱重构。
  • 可通过级联多个扩展腔半导体激光器(ECDLs),通过无缝拼接各激光器的波形,实现光谱带宽的扩展。
  • 利用高FSR微腔(如Si3N4)与类似vernier的校准方案,对ECDL中的模式跳变进行自校准,确保频率精度。
Figure 1: Principle and architecture of the vector spectrum analyzer (VSA) . a . The principle of our VSA is based on a chirping CW laser that is sent to and transmits through a device under test (DUT). The DUT can be either a passive device or a broadband laser source. The transmission spectrum of
Figure 1: Principle and architecture of the vector spectrum analyzer (VSA) . a . The principle of our VSA is based on a chirping CW laser that is sent to and transmits through a device under test (DUT). The DUT can be either a passive device or a broadband laser source. The transmission spectrum of

实验结果

研究问题

  • RQ1基于光纤的VSA能否在无需高速调制器或主动反馈的情况下,实现亚兆赫级频率分辨率与太赫兹级带宽?
  • RQ2啁啾激光系统利用无源频率参考,能否精确地将光学频率响应映射至时域?
  • RQ3单一VSA系统在高动态范围与相位灵敏度下,能在多大程度上同时表征被动光子器件与超宽带激光源?
  • RQ4该系统能否在LiDAR和光谱学等现场部署应用中保持长期稳定与高精度?
  • RQ5当通过多个ECDLs与校准微腔扩展系统时,其光谱分辨率与带宽的性能极限是什么?

主要发现

  • VSA实现55.1 THz(1260–1640 nm)的光谱带宽,可完整表征C波段与L波段中宽带集成光子组件。
  • 系统展示471 kHz的频率分辨率,可从复杂光学信号(如频率梳)中提取精细光谱细节。
  • VSA的动态范围达56 dB,支持对微弱光谱特征的高灵敏度检测。
  • 在LiDAR模式下,系统实现7.6 μm的距离分辨率与20.3 nm的精度,经4625次测量验证。
  • VSA成功映射了集成色散波导的色散与损耗特性,证实了相位与群速度延迟测量的准确性。
  • 系统无需高速调制器、光电探测器或主动反馈,仅依赖无源频率校准,实现紧凑、坚固且可移动的设计。
Figure 2: Frequency-calibration of the fiber cavity . a . Experimental setup. PM, phase modulator. PC, polarization controller. PD, photodetector. OSC, oscilloscope. FFT, fast Fourier Transformation. b-d . Principle of frequency-calibration process of the fiber cavity’s FSR. Charts compare the diffe
Figure 2: Frequency-calibration of the fiber cavity . a . Experimental setup. PM, phase modulator. PC, polarization controller. PD, photodetector. OSC, oscilloscope. FFT, fast Fourier Transformation. b-d . Principle of frequency-calibration process of the fiber cavity’s FSR. Charts compare the diffe

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。