Skip to main content
QUICK REVIEW

[论文解读] Continuous sPatial-Temporal Deformable Image Registration (CPT-DIR) for motion modelling in radiotherapy: beyond classic voxel-based methods

Xia Li, Muheng Li|arXiv (Cornell University)|May 1, 2024
Advanced Radiotherapy TechniquesPhysics and Astronomy被引用 3
一句话总结

本文提出CPT-DIR,一种基于隐式神经表示(INR)的连续时空可变形图像配准方法,将患者解剖结构运动建模为时空连续过程。通过统一欧拉框架与拉格朗日框架,CPT-DIR在特征点与轮廓配准方面实现更高精度,尤其在肺-胸壁等复杂区域表现优异,优于传统体素基DIR方法在插值、自动化与速度方面的性能。

ABSTRACT

Background and purpose: Deformable image registration (DIR) is a crucial tool in radiotherapy for extracting and modelling organ motion. However, when significant changes and sliding boundaries are present, it faces compromised accuracy and uncertainty, determining the subsequential contour propagation and dose accumulation procedures. Materials and methods: We propose an implicit neural representation (INR)-based approach modelling motion continuously in both space and time, named Continues-sPatial-Temporal DIR (CPT-DIR). This method uses a multilayer perception (MLP) network to map 3D coordinate (x,y,z) to its corresponding velocity vector (vx,vy,vz). The displacement vectors (dx,dy,dz) are then calculated by integrating velocity vectors over time. The MLP's parameters can rapidly adapt to new cases without pre-training, enhancing optimisation. The DIR's performance was tested on the DIR-Lab dataset of 10 lung 4DCT cases, using metrics of landmark accuracy (TRE), contour conformity (Dice) and image similarity (MAE). Results: The proposed CPT-DIR can reduce landmark TRE from 2.79mm to 0.99mm, outperforming B-splines' results for all cases. The MAE of the whole-body region improves from 35.46HU to 28.99HU. Furthermore, CPT-DIR surpasses B-splines for accuracy in the sliding boundary region, lowering MAE and increasing Dice coefficients for the ribcage from 65.65HU and 90.41% to 42.04HU and 90.56%, versus 75.40HU and 89.30% without registration. Meanwhile, CPT-DIR offers significant speed advantages, completing in under 15 seconds compared to a few minutes with the conventional B-splines method. Conclusion: Leveraging the continuous representations, the CPT-DIR method significantly enhances registration accuracy, automation and speed, outperforming traditional B-splines in landmark and contour precision, particularly in the challenging areas.

研究动机与目标

  • 解决离散体素基可变形图像配准(DIR)在处理大范围解剖结构变化和滑动边界时的局限性。
  • 将器官运动建模为时空连续过程,以反映其真实的物理特性。
  • 统一欧拉与拉格朗日运动描述方式,实现更自然且精确的运动表征。
  • 提升配准与插值精度,尤其在肺-胸壁边界等复杂解剖界面中。
  • 实现实时、自动化且可靠的轮廓传播与剂量累积,以支持自适应放疗。

提出的方法

  • 该方法采用隐式神经表示(INR)将患者解剖结构建模为时空连续函数,实现平滑且可微的运动场。
  • 在统一的INR框架内整合欧拉(固定网格)与拉格朗日(物质点)描述方式,以捕捉空间与时间的连续性。
  • 通过可微损失函数端到端优化连续运动场,强制施加空间与时间平滑性,并与观测图像数据保持一致。
  • 通过连续INR表示自然支持帧插值,实现中间运动状态的高保真重建。
  • 该方法避免体素网格伪影,实现形变估计与轮廓传播的亚体素级精度。
  • 该方法在4D-CT数据上进行训练与评估,通过基于梯度的学习算法优化连续INR参数。

实验结果

研究问题

  • RQ1与离散体素基方法相比,连续时空表示是否能提升放疗中可变形图像配准的精度?
  • RQ2欧拉与拉格朗日运动描述方式的融合在解剖复杂区域中如何增强运动建模能力?
  • RQ3连续INR方法在具有滑动边界的区域中,对特征点与轮廓配准精度的提升程度如何?
  • RQ4该方法是否能在不依赖时间点间离散插值的情况下实现高精度帧插值?
  • RQ5连续形式是否能实现实时、更自动化且更可靠的轮廓传播与剂量累积,以支持自适应放疗?

主要发现

  • CPT-DIR在特征点配准方面显著优于传统DIR方法,尤其在肺-胸壁界面等复杂运动区域表现突出。
  • 该方法展现出更优的轮廓精度,显著降低时间序列中结构勾画的误差,尤其在大形变区域。
  • 使用CPT-DIR进行帧插值可生成视觉与定量上更平滑的运动序列,且无体素基插值常见的伪影。
  • 连续INR表示支持更快推理与自动化处理,减少临床工作流中对手动修正的依赖。
  • 该方法对大范围解剖变化与滑动边界具有鲁棒性,而传统DIR常在此类情况下失效或产生不一致结果。
  • 在连续框架中整合欧拉与拉格朗日描述方式,可生成更具物理合理性和一致性的运动场。

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。