[论文解读] Diffusion Probabilistic Models beat GANs on Medical Images
Medfusion,条件潜在扩散概率模型,在保真度和多样性方面均优于GAN,在眼科、放射科和病理学数据集的FID、精确度与召回率方面均有领先。
The success of Deep Learning applications critically depends on the quality and scale of the underlying training data. Generative adversarial networks (GANs) can generate arbitrary large datasets, but diversity and fidelity are limited, which has recently been addressed by denoising diffusion probabilistic models (DDPMs) whose superiority has been demonstrated on natural images. In this study, we propose Medfusion, a conditional latent DDPM for medical images. We compare our DDPM-based model against GAN-based models, which constitute the current state-of-the-art in the medical domain. Medfusion was trained and compared with (i) StyleGan-3 on n=101,442 images from the AIROGS challenge dataset to generate fundoscopies with and without glaucoma, (ii) ProGAN on n=191,027 from the CheXpert dataset to generate radiographs with and without cardiomegaly and (iii) wGAN on n=19,557 images from the CRCMS dataset to generate histopathological images with and without microsatellite stability. In the AIROGS, CRMCS, and CheXpert datasets, Medfusion achieved lower (=better) FID than the GANs (11.63 versus 20.43, 30.03 versus 49.26, and 17.28 versus 84.31). Also, fidelity (precision) and diversity (recall) were higher (=better) for Medfusion in all three datasets. Our study shows that DDPM are a superior alternative to GANs for image synthesis in the medical domain.
研究动机与目标
- 证明DDPMs在跨多个领域的医疗图像生成质量上优于GAN。
- 评估Medfusion自编码器的重建质量及其对基于扩散的合成的影响。
- 在三个公开的医疗图像数据集上将Medfusion与前沿GANs进行标准指标的比较。
- 为研究社区提供可开源访问的Medfusion。
提出的方法
- 使用一个两部分的Medfusion模型,将自编码器与潜在DDPM结合,生成256x256和512x512的医疗图像。
- 训练自编码器将图像压缩到潜在空间,并使用多分辨率损失进行重建。
- 用DDPM扩散潜在空间并用UNet去噪,采用DDIM在t=150步进行采样。
- 在GANs上进行对比:在AIROGS上使用StyleGAN-3,在CheXpert上使用ProGAN,在CRCDX上使用cGAN。
- 使用标准参考批次,基于FID、改进的精确度与召回率,以及MS-SSIM进行评估。
实验结果
研究问题
- RQ1潜在DDPM(Medfusion)是否在眼科、放射科和病理学数据集上产生比GAN更高质量的医疗图像?
- RQ2Medfusion中的自编码器在压缩与重建过程中是否能够保留医学相关细节?
- RQ3Medfusion与GAN在保真度(精度)和多样性(召回)方面在不同数据集上的对比如何?
- RQ4与GAN相比,DDPM基础的医疗图像合成中出现了哪些伪影或局限性?
- RQ5自编码器设计和采样步数对最终图像质量有何影响?
主要发现
- Medfusion在AIROGS(11.63 vs 20.43)、CRCDX(30.03 vs 49.26)和CheXpert(17.28 vs 84.31)的FID上均实现了更低的得分(更好)。
- Medfusion在AIROGS(0.70 vs 0.43)、CRCDX(0.66 vs 0.64)和CheXpert(0.68 vs 0.30)的精确度(保真度)方面高于GAN。
- Medfusion在AIROGS(0.40 vs 0.19)、CRCDX(0.41 vs 0.02)和CheXpert(0.32 vs 0.17)的召回率(多样性)方面高于GAN。
- GANs表现出可识别的伪影(眼底的两个光盘、病理切片中的网格模式、胸部X线中的字母模糊等),在Medfusion中未观察到。
- 自编码器重建在AIROGS与CheXpert上几乎完美(MS-SSIM约0.98–0.99,MSE约1e-5),在CRCDX上由于更高分辨率存在数据集特定的损失。
阅读本论文
在 Nubint 阅读器中打开原文,边读边就任意段落提问。
在 Nubint 中阅读本论文本解读由 AI 根据论文原文生成,引用前请核对原文。