[论文解读] Dynamical analysis of biological signals with the 0-1 test
本文将0–1检验应用于生物信号,特别是健康年轻个体的光电容积脉搏波(PPG)信号,以分类其动力学行为。通过一种基于时间序列的方法计算增长率 $K_c$,研究发现PPG信号表现出准周期性动力学($K_c \approx 0.357$),与混沌($K_c \approx 1$)或周期性($K_c \approx 0.094$)信号相区别,表明心脏与呼吸系统之间存在潜在耦合。
The 0-1 test distinguishes between regular and chaotic dynamics for a deterministic system using a time series. Here is presented how to use the test with biological signals. Between all the biological signals obtained as a times series, we present the results of applying the test and study with more details the photoplethysmogram (PPG) from different subjects; different biological signals of one subject are analyzed also with the test. PPG signal contains extensive physiological dynamics information; mainly used to heart rate monitoring and blood oxygen saturation. Based on its understandable statistics, several indices have been proposed and may apply to some clinical needs. However, continuous real-time monitoring, of the non-stationary biological signals, is frequently used on the modern intensive care unit. A deep understanding of the PPG signal will allow finding algorithms to evaluate other possible indices that give information about the dynamical system that constitutes the human body. We demonstrate that the PPG signal, as a time series, on a healthy individual, is a quasi-periodic signal. The parameters calculated for the analysis give some ideas of what the quasi-periodic properties mean. Results are on PPG signals from different healthy young people. The dynamical analysis of the PPG signal applying the 0-1 test allows distinguishing a regular dynamic, periodic o quasi-periodic, from a chaotic dynamics operating directly over the time series. The result obtained is compared with the results from well known time series that are random, chaotic, aperiodic, periodic, and quasi-periodic.
研究动机与目标
- 评估生物信号的动力学行为,特别是PPG,使用无需相空间重构的时间序列方法。
- 确定健康年轻受试者PPG信号是否表现出规则、周期性、准周期性、混沌或随机动力学。
- 评估0–1检验在真实世界生物信号(包括PPG、EMG和体温数据)中的适用性。
- 探讨生理噪声或应激如何改变PPG信号的动力学特征,表现为$K_c$的变化。
- 为识别非平稳生物信号中动力学转变提供定量框架,适用于重症监护监测。
提出的方法
- 将0–1检验应用于时间序列数据$s(n)$,通过余弦和正弦分量以常数$c \in (0, 2\pi)$计算二维轨迹$p_c(n)$和$q_c(n)$。
- 计算均方位移(MSD),$M_c(n)$,即时间延迟$n$下轨迹对的平均平方位移。
- 增长率$K_c$由公式$K_c = \lim_{n \to \infty} \frac{\log M_c(n)}{\log n}$推导得出,其中$K_c \approx 0$表示规则动力学,$K_c \approx 1$表示混沌动力学。
- 为增强鲁棒性,$K_c$在100个随机$c$值上计算并使用相关性方法取平均。
- 在已知参考信号(周期性、准周期性、混沌性、随机性)上验证该方法后,再应用于生物数据。
- 从健康受试者中采集PPG、EMG和体温信号,并在分析前通过预处理减少运动伪影。
实验结果
研究问题
- RQ1健康年轻个体的PPG信号是否表现出准周期性、周期性、混沌性或随机性动力学?
- RQ20–1检验能否在无需相空间重构的情况下可靠地区分生物时间序列中的不同动力学状态?
- RQ3同一受试者中,PPG信号的$K_c$值与其他生物信号(如EMG和体温)相比如何?
- RQ4当引入噪声或生理应激时,PPG信号的动力学特征如何变化,表现为$K_c$值的偏移?
- RQ5心脏与呼吸节律之间的耦合在PPG信号中以何种程度体现为准周期性?
主要发现
- 健康年轻个体的PPG信号表现出准周期性动力学,五名受试者中$K_c \approx 0.357$,表明其为稳定、非混沌但非周期性的行为。
- 0–1检验成功将PPG信号与混沌和周期性参考信号区分开,周期性信号(100 Hz正弦波)的$K_c = 0.094$,而混沌和随机信号的$K_c \approx 1$。
- 同一受试者EMG信号表现出异质的$K_c$值,部分区域显示混沌或随机行为,可能源于测量伪影或非平稳性。
- 同一受试者手指和脸颊体温信号表现出截然不同的动力学行为,提示其背后存在不同的生理调节机制。
- 跨受试者PPG信号中$K_c < 0.5$且$K_c > 0.2$的特征确认了稳定的准周期性签名,支持心脏与呼吸调节耦合的假设。
- 本研究表明,$K_c$值低于0.5,特别是约0.357,是PPG中生理准周期性的指标,而非噪声或测量误差。
阅读本论文
在 Nubint 阅读器中打开原文,边读边就任意段落提问。
在 Nubint 中阅读本论文本解读由 AI 根据论文原文生成,引用前请核对原文。