本文提出了一种基于排队论的数学框架,采用递归降维(Recursive Dimensionality Reduction)方法,量化基于人工智能的分诊设备(CADt)在放射科工作流程中的时间节省效果。该框架模拟了在多位放射科医生和患者到达场景下,对时间敏感病例的等待时间减少情况,表明当AI性能最优(95%敏感度,89%特异度)、疾病流行率高且放射科医生人手不足时,CADt设备在繁忙、人员短缺的诊所中最为有效,可将患病患者的平均等待时间减少最多达-40分钟。
In the past decade, Artificial Intelligence (AI) algorithms have made promising impacts to transform healthcare in all aspects. One application is to triage patients' radiological medical images based on the algorithm's binary outputs. Such AI-based prioritization software is known as computer-aided triage and notification (CADt). Their main benefit is to speed up radiological review of images with time-sensitive findings. However, as CADt devices become more common in clinical workflows, there is still a lack of quantitative methods to evaluate a device's effectiveness in saving patients' waiting times. In this paper, we present a mathematical framework based on queueing theory to calculate the average waiting time per patient image before and after a CADt device is used. We study four workflow models with multiple radiologists (servers) and priority classes for a range of AI diagnostic performance, radiologist's reading rates, and patient image (customer) arrival rates. Due to model complexity, an approximation method known as the Recursive Dimensionality Reduction technique is applied. We define a performance metric to measure the device's time-saving effectiveness. A software tool is developed to simulate clinical workflow of image review/interpretation, to verify theoretical results, and to provide confidence intervals of the performance metric we defined. It is shown quantitatively that a triage device is more effective in a busy, short-staffed setting, which is consistent with our clinical intuition and simulation results. Although this work is motivated by the need for evaluating CADt devices, the framework we present in this paper can be applied to any algorithm that prioritizes customers based on its binary outputs.
研究动机与目标
- 为解决缺乏量化方法评估基于人工智能的分诊设备(CADt)在减少时间敏感诊断患者等待时间方面的不足。
- 开发一种数学上严谨的框架,用于建模包含多位放射科医生、优先级类别和紧急病例的临床工作流程。
- 定义并计算性能指标δWD,用于衡量在有无CADt情况下,患病但非紧急患者图像的平均等待时间减少量。
- 利用仿真工具结合置信区间验证理论预测,确保其临床相关性。
- 使该框架可广泛应用于医疗领域及其他领域中其他优先级算法的评估。
提出的方法
- 研究采用具有三个优先级等级的多类别排队模型:紧急病例(最高)、AI阳性病例(中等)和AI阴性病例(最低),并使用泊松到达过程。
- 应用递归降维(RDR)技术,近似复杂排队系统的稳态分布,从而实现平均等待时间的可计算性。
- 关键参数包括疾病流行率π、AI敏感度(Se)和特异度(Sp)、到达率λ、放射科医生阅片速率、放射科医生人数Nrad,以及紧急病例占比fem。
- 性能指标δWD = WD,without − WD,with 定义为在有无CADt情况下,患病但非紧急病例的平均等待时间之差。
- 开发仿真工具以验证理论结果、计算置信区间,并探索不同临床设置下的参数空间。
- 该框架可推广至任何输出为二元分类的算法,用于在排队系统中优先处理高风险客户或任务。

实验结果
研究问题
- RQ1在多位放射科医生、多优先级的临床工作流程中,CADt设备的存在如何影响时间敏感、患病患者图像的平均等待时间?
- RQ2在何种AI敏感度与特异度的平衡下,能最大化对患病患者的时间节省效果?
- RQ3临床因素如患者到达率、放射科医生工作负荷和紧急病例频率如何影响CADt设备的有效性?
- RQ4在何种临床环境中——特别是人员配置和患者流量方面——CADt设备最能有效减少等待时间?
- RQ5在多样化参数配置下,理论预测的等待时间减少量与仿真结果的一致性程度如何?
主要发现
- 理论框架预测,CADt设备在繁忙、人员短缺的临床环境中最为有效,此时高患者流量与有限的放射科医生资源放大了时间节省的效益。
- 在典型AI性能(95%敏感度,89%特异度)下,模型预测患病但非紧急患者图像的平均等待时间可减少最多达-40分钟。
- 这一40分钟的减少量相当于潜在使11%的LVO卒中患者残疾程度降低,超过9例NNTB(需治疗人数以避免一例不良结局),以及超过1.4 MNT(更快治疗分钟数)。
- 当假阳性率(FPR)和真正阳性率(TPR)过高时,CADt的时间节省效果下降,因为过多的AI阳性病例稀释了优先级分配的优势。
- 在极端值(FPR=1,TPR=1)时,δWD回归零,因为所有图像均被优先处理,各类别间差异消失,导致优势被抵消。
- 理论预测的δWD与仿真结果高度一致,所有估计值均落在测试场景下的95%置信区间内。