[论文解读] Extracting Randomness From The Trend of IPI for Cryptographic Operators in Implantable Medical Devices
本文提出MRE-IPI,一种新颖方法,通过从植入式医疗设备(IMDs)中脉冲间期(IPI)信号的趋势中提取随机性,生成密码学强度的强随机数。通过将IPI趋势建模为鞅过程,MRE-IPI实现了高鲁棒性与部分持久性,在NIST STS和Dieharder测试中优于现有基于IPI的方法——其随机性质量达到AES的一半水平,因此适合作为资源受限IMDs中密钥交换的一次性密码本。
Achieving secure communication between an Implantable Medical Device (IMD) inside the body and a gateway outside the body has showed its criticality with recent reports of hackings. The use of asymmetric cryptography is not a practical solution for IMDs due to the scarce computational and power resources, symmetric key cryptography is preferred. One of the factors in security of a symmetric cryptographic system is to use a strong key for encryption. A solution without using extensive resources in an IMD, is to extract it from the body physiological signals. To have a strong enough key, the physiological signal must be a strong source of randomness and InterPulse Interval (IPI) has been advised to be such that. A strong randomness source should have five conditions: Universality, Liveness, Robustness Permanence and Uniqueness. Nevertheless, for current proposed random extraction methods from IPI these conditions (mainly last three conditions) were not examined. In this study, firstly, we proposed a methodology to measure the last three conditions. Then, using a huge dataset of IPI values, we showed that IPI does not have conditions of Robustness and Permanence. Thus, extraction of a strong uniform random number from IPI value, mathematically, is impossible. Thirdly, rather than using the value of IPI, we proposed the trend of IPI as a source for a new randomness extraction method named as Martingale Randomness Extraction from IPI (MRE-IPI). MRE-IPI satisfies the Robustness condition completely and Permanence to some level. We, also, used randomness test suites and showed that MRE-IPI is able to outperform all recent randomness extraction methods from IPIs and its quality is half of the AES random number. To the best of our knowledge, this is the first work in this area which uses such a comprehensive method and large dataset to examine the randomness of a physiological signal.
研究动机与目标
- 为解决因加密密钥薄弱或静态而导致植入式医疗设备(IMDs)存在关键安全漏洞的问题。
- 评估IPI信号——常被提议作为随机性来源——是否满足核心随机性标准:鲁棒性、持久性和唯一性。
- 开发并验证一种新型随机性提取方法,以克服在IMDs中直接使用IPI值的局限性。
- 建立一个全面的生理信号基随机性评估框架,结合大规模数据与标准化测试套件。
提出的方法
- 提出一种新颖的随机性提取方法——基于IPI的鞅随机性提取(MRE-IPI),该方法使用IPI值的趋势而非其原始值。
- 将IPI趋势建模为鞅随机过程,以确保在保密度量下的信息论鲁棒性。
- 应用Santha-Vazirani delta值与依赖性分析,定量评估随机性来源的持久性与唯一性。
- 利用近9亿个IPI值的数据集,对随机性属性进行实证评估并验证该方法。
- 使用NIST统计测试套件(STS)与Dieharder测试套件评估MRE-IPI的统计质量。
- 提出将MRE-IPI用作一次性密码本以实现安全密钥交换,从而最小化暴露并增强安全性。
实验结果
研究问题
- RQ1原始IPI值是否满足IMDs中强随机性来源所必需的核心标准:鲁棒性、持久性与唯一性?
- RQ2IPI值的趋势能否被建模为鞅过程,以确保信息论鲁棒性并减少对历史值的依赖?
- RQ3MRE-IPI在统计质量与标准随机性测试套件符合度方面,相较于现有基于IPI的随机性提取方法表现如何?
- RQ4MRE-IPI在多大程度上实现了持久性与唯一性?尽管存在残余历史依赖性,其在实际应用中是否仍可安全使用?
- RQ5MRE-IPI能否在资源受限的IMDs中高效实现,同时保持高质量随机性以支持安全密钥交换?
主要发现
- 原始IPI值因对历史值的高依赖性以及在保密度量下的随机性不足,无法满足鲁棒性与持久性条件。
- MRE-IPI在所有保密度量下均实现完全鲁棒性,包括无条件保密,并展现出对敌对预测的强大抵抗力。
- MRE-IPI在NIST STS套件中取得近乎完美的得分,Dieharder测试成功率高达45%,与AES随机数生成器质量的一半相当。
- 尽管存在残余历史依赖性,MRE-IPI的依赖性显著低于原始IPI,表明其持久性得到显著改善。
- 该方法计算轻量,适合在功耗与尺寸受限的IMDs中实现,支持通过一次性密码本实现安全密钥交换。
- 本研究建立了生理信号基随机性的全面评估框架,为未来研究设立了基准。
阅读本论文
在 Nubint 阅读器中打开原文,边读边就任意段落提问。
在 Nubint 中阅读本论文本解读由 AI 根据论文原文生成,引用前请核对原文。