Skip to main content
QUICK REVIEW

[论文解读] Injecting and removing malignant features in mammography with CycleGAN: Investigation of an automated adversarial attack using neural networks

Anton S. Becker, Lukáš Jendele|arXiv (Cornell University)|Nov 19, 2018
AI in cancer detectionComputer Science参考文献 7被引用 3
一句话总结

本研究提出使用CycleGAN自动在乳房X光片中注入或移除恶性特征,表明此类由人工智能中介的篡改行为可误导放射科医生错误判断癌症状态。在高分辨率下,由于可见伪影,该攻击可被检测到;但在低分辨率下,检测准确率显著降低,暴露出人工智能辅助乳腺X光检查系统中的关键漏洞。

ABSTRACT

$ extbf{Purpose}$ To train a cycle-consistent generative adversarial network (CycleGAN) on mammographic data to inject or remove features of malignancy, and to determine whether these AI-mediated attacks can be detected by radiologists. $ extbf{Material and Methods}$ From the two publicly available datasets, BCDR and INbreast, we selected images from cancer patients and healthy controls. An internal dataset served as test data, withheld during training. We ran two experiments training CycleGAN on low and higher resolution images ($256 imes 256$ px and $512 imes 408$ px). Three radiologists read the images and rated the likelihood of malignancy on a scale from 1-5 and the likelihood of the image being manipulated. The readout was evaluated by ROC analysis (Area under the ROC curve = AUC). $ extbf{Results}$ At the lower resolution, only one radiologist exhibited markedly lower detection of cancer (AUC=0.85 vs 0.63, p=0.06), while the other two were unaffected (0.67 vs. 0.69 and 0.75 vs. 0.77, p=0.55). Only one radiologist could discriminate between original and modified images slightly better than guessing/chance (0.66, p=0.008). At the higher resolution, all radiologists showed significantly lower detection rate of cancer in the modified images (0.77-0.84 vs. 0.59-0.69, p=0.008), however, they were now able to reliably detect modified images due to better visibility of artifacts (0.92, 0.92 and 0.97). $ extbf{Conclusion}$ A CycleGAN can implicitly learn malignant features and inject or remove them so that a substantial proportion of small mammographic images would consequently be misdiagnosed. At higher resolutions, however, the method is currently limited and has a clear trade-off between manipulation of images and introduction of artifacts.

研究动机与目标

  • 调查CycleGAN是否能够学习并注入恶性特征到乳房X光图像中,以误导放射科医生。
  • 评估放射科医生是否能够检测到乳房X光片中的人工智能中介图像篡改。
  • 评估在不同图像分辨率下,有效恶性特征注入与伪影引入之间的权衡。
  • 探索使用生成式人工智能进行对抗性攻击在医学影像中的可行性与风险。
  • 确定此类攻击对诊断准确率和患者安全的临床影响。

提出的方法

  • 在两个公开的乳房X光数据集(BCDR和INbreast)上训练CycleGAN,以实现癌变与健康乳腺组织分布之间的图像转换。
  • 采用循环一致性生成对抗网络架构,配备成对的生成器和判别器网络,实现在两个方向上的图像到图像转换。
  • 将图像重采样为256×256像素和512×408像素,分别用于两个独立实验,以评估分辨率依赖的性能表现。
  • 在训练期间应用数据增强(旋转、缩放、对比度扰动)以提高泛化能力。
  • 保留一个内部私有数据集用于测试泛化能力及放射科医生的阅片结果。
  • 使用5分制恶性程度可能性评分和5分制篡改检测评分进行放射科医生阅片,并通过ROC分析(AUC)进行分析。

实验结果

研究问题

  • RQ1CycleGAN是否能够隐式学习并注入恶性特征到乳房X光图像中,以误导放射科医生?
  • RQ2放射科医生能否可靠地检测到人工智能篡改的乳房X光片?检测准确率是否依赖于图像分辨率?
  • RQ3在高分辨率图像中,有效恶性特征注入与可见伪影引入之间的权衡如何?
  • RQ4CycleGAN攻击在低分辨率与高分辨率乳房X光片中的表现有何差异?
  • RQ5该攻击在多大程度上损害了诊断准确率?人类专家能否检测到该攻击?

主要发现

  • 在低分辨率(256×256像素)下,一名放射科医生的癌症检测能力显著下降(AUC 0.63 vs. 0.85,p=0.06),其余医生未受影响。
  • 在高分辨率(512×408像素)下,所有三名放射科医生的癌症检测能力均显著下降(AUC 0.59–0.69 vs. 0.77–0.84,p=0.008),表明诊断普遍失败。
  • 尽管诊断准确率下降,但在高分辨率下,放射科医生能够以高可靠性检测出被篡改的图像(AUC 0.92、0.92和0.97),原因在于可见伪影。
  • 该攻击在高分辨率下引入了明显的伪影,尽管恶性特征注入有效,但降低了隐蔽性。
  • 本研究证实,CycleGAN能够隐式学习恶性特征,并以误导放射科医生的方式篡改乳房X光图像,尤其在低分辨率下更为显著。
  • 结果凸显了人工智能驱动医学影像系统中的关键漏洞:对抗性攻击可损害诊断准确率,同时在高分辨率下仍可被人类专家检测到。

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。