一句话总结

本文提出了一种最坏情况情景方法,用于评估近100%可再生能源电力系统的鲁棒性,利用西班牙过去十年的小时级数据,确定光伏和储能的最佳容量。研究发现,在调度性水电占比40%且光伏与储能成本下降的条件下,系统可实现可靠、低成本的电力供应,且平准化电力成本(LCOE)低于当前市场价格。

ABSTRACT

Several research studies have shown that future sustainable electricity systems, mostly based on renewable generation and storage, are feasible with current technologies and costs. However, recent episodes of extreme weather conditions, probably associated with climate change, cast shades of doubt on whether the resulting generation portfolios are sufficiently robust to assure, at all times, a suitable balance between generation and demand, when adverse conditions are faced. To address this issue, this work elaborates a methodology intended to determine a sustainable electricity system that can endure extreme weather conditions, which are likely to occur. First, using hourly production and demand data from the last decade, along with estimates of new uses of electricity, a worst-case scenario is constructed, including the storage capacity and additional photovoltaic power which are needed to serve the demand on an hourly basis. Next, several key parameters which may have a significant influence on the LCOE are considered, and a sensitivity analysis is carried out to determine their real impact, significance and potential trends. The proposed methodology is then applied to the Spanish system. The results show that, under the hypotheses and conditions considered in this paper, it is possible to design a decarbonized electricity system that, taking advantage of existing sustainable assets, satisfies the long-term needs by providing a reliable supply at an average cost significantly lower than current market prices.

研究动机与目标

  • 开发一种在极端天气条件下评估可再生能源电力系统鲁棒性的方法。
  • 确定在最坏情况情景下,实现全天候可靠供电所需的光伏与储能容量。
  • 分析平准化电力成本(LCOE)对关键系统参数(如风能利用率、水电调度性、电池成本及光伏部署规模)的敏感性。

提出的方法

  • 利用过去十年的小时级发电与负荷数据,构建西班牙电力系统在最坏情况下的情景。
  • 应用迭代优化算法,确定在极端条件下满足每小时负荷需求的光伏与电池储能容量。
  • 根据选定的调度性水平(40%、55%、70%、85%),将调度性水电与常规水电分开处理。
  • 采用动态能量平衡方程,确保每小时供需平衡,同时考虑储能的充放电过程及荷电状态(SoC)约束。
  • 通过迭代方式逐步减小储能容量,直至找到仍能满足所有小时供需平衡的最小可行容量。
  • 为每种优化后的光伏与储能配置估算LCOE,并在光伏容量增加、储能容量减少时更新成本。

实验结果

研究问题

  • RQ1在西班牙最坏天气与负荷条件下,为确保100%可再生能源供电,所需的最小光伏与储能容量是多少?
  • RQ2平准化电力成本(LCOE)对风能利用率、水电调度性及电池成本等关键参数的变化有多敏感?
  • RQ3光伏与储能技术的预期成本下降在完全可再生能源系统中,能在多大程度上降低LCOE?

主要发现

  • 在研究假设下,西班牙系统在最坏情况下的LCOE低于当前批发市场价格。
  • 调度性水电占比每提高10%,LCOE降低0.4%,但超过40%后收益递减。
  • 光伏或电池成本降低10%,将导致LCOE下降2%,若成本趋势持续,LCOE年降幅最高可达8%。
  • 当至少40%的水电具备调度性时,所需储能容量较小,表明水电在系统稳定性中起关键作用。
  • 该方法成功识别出最优的可再生能源与储能组合,可确保可靠、低成本、脱碳化的电力供应。
  • 所提出的方法具有普适性,可推广应用于其他系统与纬度地区。