Skip to main content
QUICK REVIEW

[论文解读] Slice-wise quality assessment of high b-value breast DWI via deep learning-based artifact detection

Ameya Markale, Luise Brock|arXiv (Cornell University)|Mar 4, 2026
MRI in cancer diagnosisMedicine被引用 0
一句话总结

该研究使用 CNN 在高 b 值乳腺 DWI(b=1500 s/mm2)的逐切片基础上检测和分类高强度和低强度伪影,DenseNet121 在保留数据上获得强力 AUROC/AUPRC,并通过 Grad-CAM 进行边界框的可视化定位。

ABSTRACT

Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast magnetic resonance imaging (MRI), however especially high b-value diffusion-weighted acquisitions can be prone to intensity artifacts that can affect diagnostic image assessment. This study aims to detect both hyper- and hypointense artifacts on high b-value diffusion-weighted images (b=1500 s/mm2) using deep learning, employing either a binary classification (artifact presence) or a multiclass classification (artifact intensity) approach on a slice-wise dataset.This IRB-approved retrospective study used the single-center dataset comprising n=11806 slices from routine 3T breast MRI examinations performed between 2022 and mid-2023. Three convolutional neural network (CNN) architectures (DenseNet121, ResNet18, and SEResNet50) were trained for binary classification of hyper- and hypointense artifacts. The best performing model (DenseNet121) was applied to an independent holdout test set and was further trained separately for multiclass classification. Evaluation included area under receiver operating characteristic curve (AUROC), area under precision recall curve (AUPRC), precision, and recall, as well as analysis of predicted bounding box positions, derived from the network Grad-CAM heatmaps. DenseNet121 achieved AUROCs of 0.92 and 0.94 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.85 and 0.88 for multiclass classification on single-slice high b-value diffusion-weighted images. A radiologist evaluated bounding box precision on a 1-5 Likert-like scale across 200 slices, achieving mean scores of 3.33+-1.04 for hyperintense artifacts and 2.62+-0.81 for hypointense artifacts. Hyper- and hypointense artifact detection in slice-wise breast DWI MRI dataset (b=1500 s/mm2) using CNNs particularly DenseNet121, seems promising and requires further validation.

研究动机与目标

  • 解决高 b 值乳腺 DWI(b = 1500 s/mm2)中强度伪影的挑战。
  • 开发基于逐切片的 CNN 方法以检测和分级高强度与低强度伪影。
  • 评估伪影存在的二分类与多类伪影强度分类。
  • 提供使用 Grad-CAM 推导的定位框以实现可解释性。

提出的方法

  • 从一个单中心、经 IRB 批准的队列中构建高 b 值乳腺 DWI 的 11,806 切片的 3T 乳腺 MRI 的逐切片数据集。
  • 比较 DenseNet121、ResNet18 和 SEResNet50 用于高强度与低强度伪影的二分类;为保留测试选择最佳模型。
  • 对最佳模型进行多分类伪影强度分类的训练(保留为 5 点李克特量表的类别)。
  • 对训练仅聚焦在乳腺组织上应用乳腺掩码;使用数据增强(旋转、翻转)和带类别平衡的 Adam 优化。
  • 使用 Grad-CAM 生成热力图,阈值设为 0.2,并推导边界框以定位伪影区域。
Figure 1: Schematic overview of the study workflow, including maximum intensity projection (MIP)-based case pre-selection, slice-wise data generation to form ground truth (GT), data splitting, and model selection using DenseNet121, ResNet18, and SEResNet50 architectures on the validation set for bin
Figure 1: Schematic overview of the study workflow, including maximum intensity projection (MIP)-based case pre-selection, slice-wise data generation to form ground truth (GT), data splitting, and model selection using DenseNet121, ResNet18, and SEResNet50 architectures on the validation set for bin

实验结果

研究问题

  • RQ1CNN 能否在单张高 b 值乳腺 DWI 的切片上准确检测高强度和低强度伪影?
  • RQ2哪种 CNN 架构在检测这些伪影方面表现最佳,是否能泛化到独立的保留集?
  • RQ3模型在多类伪影强度分类方面的表现如何?
  • RQ4基于 Grad-CAM 的定位是否能提供对伪影区域的可靠边界框?

主要发现

  • DenseNet121 在保留集上对高强度伪影检测的 AUROC 为 0.92、AUPRC 为 0.77。
  • DenseNet121 在保留集上对低强度伪影检测的 AUROC 为 0.94、AUPRC 为 0.92。
  • 对于多类高强度伪影,DenseNet121 的 AUROC 为 0.85、AUPRC 为 0.75(保留集)。
  • 对于多类低强度伪影,DenseNet121 的 AUROC 为 0.88、AUPRC 为 0.69(保留集)。
  • 基于 Grad-CAM 的边界框的平均定位质量为 3.33±1.04(高强度)和 2.62±0.81(低强度),尺度为 1–5。
  • 读者–模型一致性在高强度与低强度伪影评估中显示 Cohen’s kappa 的变化,表明在多类预测中标签存在一定变异性。
Figure 2: Slices affected by hyper- and hypointense artifacts on DWI (b = 1500 s/mm 2 ): a) the enclosed region shows hyperintense artifact caused by surface coil flare; b) the enclosed region shows hyperintense artifact that is likely caused by skin folding; (c-d) enclosed regions depict hypointens
Figure 2: Slices affected by hyper- and hypointense artifacts on DWI (b = 1500 s/mm 2 ): a) the enclosed region shows hyperintense artifact caused by surface coil flare; b) the enclosed region shows hyperintense artifact that is likely caused by skin folding; (c-d) enclosed regions depict hypointens

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。