Skip to main content
QUICK REVIEW

[论文解读] Sorry, Shodan is not Enough! Assessing ICS Security via IXP Network Traffic Analysis.

G. Barbieri, Mauro Conti|arXiv (Cornell University)|Jul 2, 2020
Network Security and Intrusion DetectionComputer Science被引用 5
一句话总结

本文提出了一种基于sFlow采样的大规模IXP流量分析方法,用于识别通过互联网通信的工业控制系统(ICS),并补充了Shodan的主动扫描。研究发现,Shodan遗漏了超过98%正在交换真实工业流量的ICS主机,其中75.6%的通信未使用加密和保护机制。

ABSTRACT

Modern Industrial Control Systems (ICSs) allow remote communication through the Internet using industrial protocols that were not designed to work with external networks. To understand security issues related to this practice, prior work usually relies on active scans by researchers or services such as Shodan. While such scans can identify public open ports, they are not able to provide details on configurations of the system related to legitimate Industrial Traffic passing the Internet (e.g., source-based filtering in Network Address Translation or Firewalls). In this work, we complement Shodan-only analysis with large-scale traffic analysis at a local Internet Exchange Point (IXP), based on sFlow sampling. This setup allows us to identify ICS endpoints actually exchanging Industrial Traffic over the Internet. Besides, we are able to detect scanning activities and what other type of traffic is exchanged by the systems (i.e., IT traffic). We find that Shodan only listed less than 2% of hosts that we identified as exchanging Industrial Traffic. Even with manually triggered scans, Shodan only identified 7% of them as ICS hosts. This demonstrates that active scanning-based analysis is insufficient to understand current security practices in ICS communications. We show that 75.6% of ICS hosts rely on unencrypted communications without integrity protection, leaving those critical systems vulnerable to malicious attacks.

研究动机与目标

  • 解决像Shodan这样的主动扫描工具在识别互联网上真实世界ICS通信方面的局限性。
  • 调查公共网络中ICS系统实际交换的工业流量规模与性质。
  • 检测与ICS主机相关的扫描活动及非工业(IT)流量模式。
  • 基于真实流量评估ICS系统的安全状况,特别是加密与完整性保护方面。

提出的方法

  • 利用本地互联网交换点(IXP)的sFlow采样技术,捕获并分析多个ISP的实时网络流量。
  • 应用协议指纹识别与流量模式分析,识别传输中的工业控制协议(如DNP3、Modbus)。
  • 将识别出的ICS流量与Shodan的公开端口扫描结果进行关联,比较检测覆盖范围。
  • 根据有效载荷与行为特征,将流量分类为工业、扫描、IT和未知四类。
  • 通过分析协议字段中的加密与完整性机制,评估加密保护程度。
  • 采用统计采样与过滤技术,估算系统级暴露面与配置风险。

实验结果

研究问题

  • RQ1通过被动IXP监控检测到的ICS主机中,实际在互联网上交换工业流量的数量,与Shodan发现的数量相比如何?
  • RQ2ICS系统上除了工业协议外,还交换了哪些类型的非工业流量(如扫描、IT流量)?
  • RQ3通过Shodan的主动扫描,未能检测到正在实际交换工业流量的ICS主机的比例有多大?
  • RQ4在真实世界ICS部署中,未加密且未认证通信的普遍程度如何?

主要发现

  • Shodan仅识别出通过被动IXP监控检测到的工业流量ICS主机的2%以下。
  • 即使在手动触发扫描的情况下,Shodan也仅能识别出通过流量分析确认的7%的ICS主机为工业系统。
  • 观察到的75.6%的ICS主机使用了未加密通信且缺乏完整性保护,使其易受中间人攻击与欺骗攻击。
  • 大量ICS主机被发现交换了扫描流量,表明其暴露于自动化侦察活动。
  • 非工业(IT)流量(包括SSH和HTTP)频繁出现在ICS主机上,增加了攻击面。
  • 本研究证明,仅靠主动扫描无法充分评估真实世界中的ICS安全状况,因其存在极高的检测盲区。

阅读本论文

在 Nubint 阅读器中打开原文,边读边就任意段落提问。

在 Nubint 中阅读本论文

本解读由 AI 根据论文原文生成,引用前请核对原文。