[论文解读] X-Shooter spectroscopy of young stellar objects: IV -- Accretion in low-mass stars and sub-stellar objects in Lupus
本研究利用X-Shooter/VLT对猎户座星云中36个低质量和亚恒星年轻恒星天体进行光谱观测,通过连续谱过量建模和发射线光度测量获得吸积率($ olimits_{\rm acc}$)。研究发现$ olimits_{\rm acc} \propto M_\star^{1.8\pm0.2}$,其离散度低于以往研究;在五个数量级范围内,发射线光度与$ olimits_{\rm acc}$呈线性关系;且与连续谱方法相比,H$\alpha$轮廓建模导致$ olimits_{\rm acc}$被低估0.6–0.8 dex。
We present X-Shooter/VLT observations of a sample of 36 accreting low-mass stellar and sub-stellar objects (YSOs) in the Lupus star forming region, spanning a range in mass from ~0.03 to ~1.2Msun, but mostly with 0.1Msun < Mstar < 0.5Msun. Our aim is twofold: firstly, analyse the relationship between excess-continuum and line emission accretion diagnostics, and, secondly, to investigate the accretion properties in terms of the physical properties of the central object. The accretion luminosity (Lacc), and from it the accretion rate (Macc), is derived by modelling the excess emission, from the UV to the near-IR, as the continuum emission of a slab of hydrogen. The flux and luminosity (Ll) of a large number of emission lines of H, He, CaII, etc., observed simultaneously in the range from ~330nm to 2500nm, were computed. The luminosity of all the lines is well correlated with Lacc. We provide empirical relationships between Lacc and the luminosity of 39 emission lines, which have a lower dispersion as compared to previous relationships in the literature. Our measurements extend the Pab and Brg relationships to Lacc values about two orders of magnitude lower than those reported in previous studies. We confirm that different methodologies to measure Lacc and Macc yield significantly different results: Ha line profile modelling may underestimate Macc by 0.6 to 0.8dex with respect to Macc derived from continuum-excess measures. Such differences may explain the likely spurious bi-modal relationships between Macc and other YSOs properties reported in the literature. We derive Macc in the range 2e-12 -- 4e-8 Msun/yr and conclude that Macc is proportional to Mstar^1.8(+/-0.2), with a dispersion lower by a factor of about 2 than in previous studies. A number of properties indicate that the physical conditions of the accreting gas are similar over more than 5 orders of magnitude in Macc.
研究动机与目标
- 分析低质量和亚恒星YSO中连续谱过量与发射线吸积诊断之间的关系。
- 研究吸积特性与中心恒星物理参数(特别是质量)的相关性。
- 解决因不同方法导致的吸积率测量差异。
- 将吸积光度($L_{\rm acc}$)与线状光度($L_{\rm line}$)之间的经验关系扩展至更低的$L_{\rm acc}$值,包括极低质量区域。
- 检验吸积流中的物理条件在宽广吸积率范围内是否保持一致。
提出的方法
- 将紫外至近红外波段的连续谱过量建模为局部热动平衡(LTE)下的氢板状发射,以推导$L_{\rm acc}$。
- 利用高分辨率X-Shooter光谱测量330–2500 nm波段内39条发射线(H、He、Ca ii等)的光度。
- 基于恒星质量和半径估计,结合标准磁层吸积物理模型,由$L_{\rm acc}$推导$ olimits_{\rm acc}$。
- 将H$\alpha$线轮廓拟合所得$ olimits_{\rm acc}$与连续谱过量建模结果进行比较,以评估系统性偏差。
- 建立39条线的$L_{\rm acc}$–$L_{\rm line}$经验关系,包含不确定性量化与离散度分析。
- 通过分析线强度比和光度分布,评估不同$ olimits_{\rm acc}$范围下吸积物理的一致性。
实验结果
研究问题
- RQ1基于连续谱过量与H$\alpha$线轮廓拟合所得的$L_{\rm acc}$和$ olimits_{\rm acc}$如何比较?
- RQ2在宽广吸积率范围内,$L_{\rm acc}$与各条发射线光度之间的经验关系为何?
- RQ3猎户座YSO样本中$ olimits_{\rm acc}$–$M_\star$关系是否一致?其离散度与以往研究相比如何?
- RQ4在五个数量级的吸积率范围内,吸积流中的物理条件(如线强度比、能量分布)是否独立于$ olimits_{\rm acc}$?
- RQ5不同方法推导$ olimits_{\rm acc}$所导致的系统性差异,在多大程度上解释了以往报道的吸积率关系双峰性?
主要发现
- 与基于连续谱过量的测量相比,H$\alpha$线轮廓建模导致$ olimits_{\rm acc}$被低估0.6至0.8 dex。
- $ olimits_{\rm acc}$与恒星质量的关系为$ olimits_{\rm acc} \propto M_\star^{1.8\pm0.2}$,其离散度相比以往研究降低了约两倍。
- Pa$\beta$和Br$\gamma$线表现出最可靠的$L_{\rm acc}$–$L_{\rm line}$关系,离散度更低,且对色球层活动的敏感性低于光学波段线。
- 线状光度在超过五个数量级的$ olimits_{\rm acc}$范围内几乎呈线性增长,表明吸积流中物理条件保持一致。
- 每条线所辐射的$L_{\rm acc}$比例以及氢线强度比在$ olimits_{\rm acc}$范围内基本保持恒定,支持存在统一的吸积几何结构。
- 以往报道的$ olimits_{\rm acc}$关系双峰性很可能是由于混合使用了不一致方法推导的吸积率所致。
阅读本论文
在 Nubint 阅读器中打开原文,边读边就任意段落提问。
在 Nubint 中阅读本论文本解读由 AI 根据论文原文生成,引用前请核对原文。