Skip to main content

Cheong Il Shin

Seoul National University · Medicine

About the Lab

Professor Cheong Il Shin's research lab specializes in abdominal radiology and medical imaging, with a focus on advanced MRI techniques and non-invasive biomarkers for the diagnosis and staging of liver and pancreatic diseases. The lab investigates innovative imaging modalities such as MR elastography, diffusion-weighted imaging, and gadoxetic acid-enhanced MRI to improve the accuracy of liver fibrosis and hepatocellular carcinoma detection. They also explore clinical applications of non-invasive fibrosis markers like FIB-4 in high-risk populations, aiming to enhance early diagnosis and personalized treatment strategies for chronic liver disease and pancreatic malignancies.

liver fibrosisMR elastographyhepatocellular carcinomapancreatic cancernon-invasive imaging

Research Overview

Papers
73
Total Citations
1,807
Papers (5y)
12
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
12total
2021
2022
2023
2025
2026
Citations per year (5y)
103total
20212022202320252026

Selected Papers

15
1
Article|139 citations·2013
Laparoscopy-Assisted Pylorus-Preserving Gastrectomy Is Better Than Laparoscopy-Assisted Distal Gastrectomy for Middle-Third Early Gastric Cancer
Yun‐Suhk Suh, Dong‐Seok Han, Seong‐Ho Kong, Sebastianus Kwon, Cheong‐Il Shin, Woo Ho Kim, Hyung‐Ho Kim, Hyuk‐Joon Lee, Han‐Kwang Yang
SJR Q1Annals of Surgery

For middle-third EGC, LAPPG can be considered as a better treatment option than LADG in terms of nutritional advantage and lower incidence of gallstone.

Pulmonary and Respiratory MedicineMedicine
2
Article|120 citations·2014
High liver fibrosis index FIB‐4 is highly predictive of hepatocellular carcinoma in chronic hepatitis B carriers
Beomseok Suh, Sehhoon Park, Dong Wook Shin, Jae Moon Yun, Hyung‐Kook Yang, Su Jong Yu, Cheong‐Il Shin, Jin‐Soo Kim, Eun‐Mi Ahn, Hyejin Lee, Jin‐Ho Park, Belong Cho
SJR Q1Hepatology

UNLABELLED: Screening for hepatocellular carcinoma (HCC) is clinically important given that its early detection has remarkable survival benefits. We investigated the possible role of FIB-4, a recently developed noninvasive marker for liver fibrosis based on routine laboratory tests, as a clinical indicator for predicting future HCC among hepatitis B surface antigen (HBsAg) carriers. Our retrospective cohort study involved 986 Korean HBsAg carriers 40 years of age or older who visited Seoul Natio

HepatologyMedicine
3
Article|108 citations·2012
Magnetic resonance imaging findings of the mass‐forming type of autoimmune pancreatitis: Comparison with pancreatic adenocarcinoma
Bo Yun Hur, Jeong Min Lee, Jeong Min Lee, Jeong Eun Lee, Jeong Eun Lee, Jae Yong Park, Soo Jin Kim, Ijin Joo, Cheong‐Il Shin, Jee Hyun Baek, Jung Hoon Kim, Joon Koo Han
SJR Q1Journal of Magnetic Resonance ImagingOA

PURPOSE: To determine the characteristic magnetic resonance imaging (MRI) features of mass-forming autoimmune pancreatitis (AIP), which allow its differentiation from pancreatic adenocarcinoma (PAC). MATERIALS AND METHODS: MR images of 37 patients with either pathologically proven, mass-forming AIPs (n = 9) or PACs (n = 28) were retrospectively reviewed. The pancreatic MR protocol included unenhanced images, contrast-enhanced dynamic images, diffusion-weighted imaging (DWI), and MR-cholangiopanc

RheumatologyMedicine
4
Article|104 citations·2013
MR elastography for noninvasive assessment of hepatic fibrosis: Reproducibility of the examination and reproducibility and repeatability of the liver stiffness value measurement
Ye Ji Lee, Jeong Min Lee, Jeong Min Lee, Jeong Eun Lee, Jeong Eun Lee, Kyung Bun Lee, Eun Sun Lee, Jeong Hee Yoon, Mi Hye Yu, Jee Hyun Baek, Cheong‐Il Shin, Joon Koo Han
SJR Q1Journal of Magnetic Resonance ImagingOA

PURPOSE: To determine the reproducibility of MR elastography (MRE) and the reproducibility and repeatability of the stiffness measurement of MRE in the staging of liver fibrosis. MATERIALS AND METHODS: Ninety-four patients, who underwent liver MRE, were included in this study. The patients were classified into group 1 (n = 47) and group 2 (n = 47) according to our knowledge of their histologic hepatic fibrosis (HF) stage. To analyze the reproducibility of MRE, the group 1 patients underwent MRE

EpidemiologyMedicine
5
Article|26 citations·2007
Recurrence Patterns of Combined Hepatocellular-Cholangiocarcinoma on Enhanced Computed Tomography
Cheong‐Il Shin, Jeong Min Lee, Se Hyung Kim, Jin‐Young Choi, Jae Young Lee, Joon Koo Han, Soo Yeon Jo, Byung Ihn Choi
SJR Q3Journal of Computer Assisted TomographyOA

Contrast-enhanced CT scanning can predict the dominant component of primary and recurrent HCC-CC. This capability can optimize treatment strategy for the patient with recurrent HCC-CC.

SurgeryMedicine
6
Article|24 citations·2014
High Spatial Resolution, Respiratory-Gated, T1-Weighted Magnetic Resonance Imaging of the Liver and the Biliary Tract During the Hepatobiliary Phase of Gadoxetic Acid–Enhanced Magnetic Resonance Imaging
Eun Sun Lee, Jeong Min Lee, Mi Hye Yu, Cheong‐Il Shin, Hyun Woo, Ijin Joo, Alto Stemmer, Joon Koo Han, Byung Ihn Choi
SJR Q3Journal of Computer Assisted Tomography

T1-weighted gated-VIBE showed technical feasibility for HR-T1WI during HBP imaging of gadoxetic acid-enhanced MRI.

EpidemiologyMedicine
7
Article|16 citations·2014
Ultra-low Peak Voltage CT Colonography: Effect of Iterative Reconstruction Algorithms on Performance of Radiologists Who Use Anthropomorphic Colonic Phantoms
Cheong‐Il Shin, Se Hyung Kim, Eun Sun Lee, Dong Ho Lee, Eui Jin Hwang, Se-Yeong Chung, Jeong Min Lee, Joon Koo Han, Byung Ihn Choi
SJR Q1Radiology

A decrease in tube voltage to 80 kVp caused reduction in radiation dose (0.166 mSv) with deterioration in image noise and per-polyp sensitivity. By using a knowledge-based IR iterative reconstruction algorithm, radiologists' performance of 80-kVp CT colonography was acceptable and on par with that at 100- or 120-kVp CT colonography.

Radiology, Nuclear Medicine and ImagingMedicine
8
Article|14 citations·2021
Coronary Artery Lumen Segmentation Using Location–Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept
Cheong‐Il Shin, Sang Joon Park, Ji-Hyun Kim, Yeonyee E. Yoon, Eun‐Ah Park, Bon‐Kwon Koo, Whal Lee
SJR Q1Korean Journal of RadiologyOA

SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.

Radiology, Nuclear Medicine and ImagingMedicine
9
Article|10 citations·2018
Infected cyst in patients with autosomal dominant polycystic kidney disease: Analysis of computed tomographic and ultrasonographic imaging features
Jiseon Oh, Cheong‐Il Shin, Sang Youn Kim
SJR Q1PLoS ONEOA

Minute imaging features such as minimal wall thickening or relatively high attenuation compared to normal cysts would be helpful to detect infected cysts in ADPKD patients.

GeneticsBiochemistry, Genetics and Molecular Biology
10
Review|9 citations·2020
Normal and Abnormal Postoperative Imaging Findings after Gastric Oncologic and Bariatric Surgery
Cheong‐Il Shin, Se Hyung Kim
SJR Q1Korean Journal of RadiologyOA

Surgical resection remains the primary choice of treatment and the only potentially curative option for gastric carcinoma, and is increasingly performed laparoscopically. Gastric resection represents a challenging procedure, with a significant morbidity and non-negligible postoperative mortality. The interpretation of imaging after gastric surgery can be challenging due to significant modifications of the normal anatomy. After the surgery, the familiarity with expected imaging appearances is cru

Pulmonary and Respiratory MedicineMedicine
11
Article|9 citations·2013
Rat Model of Hindlimb Ischemia Induced via Embolization with Polyvinyl Alcohol and N-Butyl Cyanoacrylate
Cheong‐Il Shin, Hyo‐Cheol Kim, Yong Sub Song, Hye Rim Cho, Kyoung Bun Lee, Whal Lee, Hwan Jun Jae, Jin Wook Chung
SJR Q1Korean Journal of RadiologyOA

The examined hindlimb ischemia model using embolization with NBCA and PVA particles in rats is a feasible model for further research, and muscle necrosis was evident as compared with the surgical model.

EpidemiologyMedicine
12
Article|8 citations·2016
One-mSv CT colonography: Effect of different iterative reconstruction algorithms on radiologists’ performance
Cheong‐Il Shin, Se Hyung Kim, Jong Pil Im, Sang Gyun Kim, Mi Hye Yu, Eun Sun Lee, Joon Koo Han
SJR Q1European Journal of Radiology
OncologyMedicine
13
Article|3 citations·2013
Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation
Cheong‐Il Shin, Se Hyung Kim, Jung Hyo Rhim, Nam‐Joon Yi, Kyung‐Suk Suh, Jeong Min Lee, Joon Koo Han, Byung Ihn Choi
SJR Q4Journal of the Korean Society of RadiologyOA
SurgeryMedicine
14
Article|1 citations·2025
Prognostic value of a new computed tomography severity score in hemorrhagic fever with renal syndrome
Se Woo Kim, Cheong‐Il Shin, Min Woo Kang, Min Cheol Kim, Donghwan Kim
SJR Q2Emergency RadiologyOA

PURPOSE: To develop of a novel computed tomography (CT) severity score for hemorrhagic fever with renal syndrome (HFRS) and evaluate its correlation with disease severity and adverse outcomes. METHODS: This retrospective study included 37 patients diagnosed with HFRS from January 2012 to December 2023 who had available clinical laboratory and abdominal CT data during the acute phase. The CT severity score (range 0-5) was based on perirenal fat stranding, pararenal fascia thickening, anterior par

Infectious DiseasesMedicine
15
Book Chapter|1 citations·2014
Small Bowel Obstruction
Cheong‐Il Shin
Radiology illustrated
SurgeryMedicine

Research Areas

SurgeryPulmonary and Respiratory MedicineRadiology, Nuclear Medicine and ImagingEpidemiologyOncologyHepatology

Dive deeper into Cheong Il Shin's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.