Hee Yeon Woo
Sungkyunkwan University · Medicine
About the Lab
Professor Hee Yeon Woo's research lab specializes in molecular diagnostics and clinical biomarker discovery, with a focus on infectious diseases, reproductive endocrinology, and oncology. The lab develops and validates sensitive molecular assays—such as DPO-PCR and mass spectrometry-based methods—for detecting antimicrobial resistance, hepatitis B virus mutations, and hormone-related biomarkers like anti-Müllerian hormone. Their work bridges laboratory innovation with clinical application, particularly in early diagnosis and personalized medicine for conditions like *H. pylori* infection, polycystic ovary syndrome, and paraneoplastic syndromes. The lab also evaluates point-of-care testing devices for renal function markers, emphasizing accuracy and practicality in routine clinical settings.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15BACKGROUND: Assessment of Helicobacter pylori (H. pylori) clarithromycin resistance has rarely been performed routinely despite an increasing resistance rate. Our aim was to develop and evaluate the use of dual-priming oligonucleotide (DPO)-based multiplex polymerase chain reaction (PCR) to detect point mutations in the 23S rRNA gene responsible for clarithromycin resistance of H. pylori. MATERIALS AND METHODS: Gastric biopsy specimens from 212 untreated patients with dyspepsia were examined by
The aim of the present study was to compare the associations of anti-Müllerian hormone (AMH) with clinical or biochemical characteristics between women with and without polycystic ovary syndrome (PCOS). We also explored the optimal cutoff point of AMH to diagnose PCOS. A cross-sectional study was performed in 87 women diagnosed with PCOS and 53 healthy control subjects. Body mass index (BMI), indices of insulin resistance, metabolic syndrome-related variables, reproductive hormones and serum AMH
Microangiopathic hemolytic anemia (MAHA) occurs occasionally as a paraneoplastic syndrome in some solid tumors, but MAHA accompanied by signet ring cell carcinoma of an unknown origin is very rare. In this study, we present the case of an 80-yr-old man who was admitted to the hospital because of a 1-month history of lower back pain and dyspnea. He was diagnosed with MAHA on the basis of the laboratory findings that revealed anemia with schistocytes, decreased haptoglobin levels, and a negative d
BACKGROUND: There is an increasing need for the early detection of emerging mutations in the tyrosine-methionine-aspartate-aspartate (YMDD) motif of hepatitis B virus (HBV) DNA polymerase with using sensitive molecular methods. METHODS: We evaluated the usefulness of monitoring lamivudine resistance using a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry-based assay (the restriction fragment mass polymorphism; RFMP) in comparison with the direct sequencing assay, the
BACKGROUND: The urine albumin/creatinine ratio (ACR) test is used to screen patients with chronic diseases, such as diabetes, hypertension and cardiovascular diseases that put them at an increased risk of developing kidney disease. Here, we evaluated the performance of the URiSCAN 2 ACR Strip (URiSCAN; YD diagnostics, Yongin, Korea), a semiquantitative point-of-care testing (POCT) assay, and we compared to an existing POCT assay and a quantitative assay. MATERIALS AND METHODS: A total of 1,020 r
BACKGROUND: This study compares the diagnostic performance (in routine urinalysis) of three URiSCAN devices and three Roche analyzers to manual microscopy and quantitative assays. METHODS: We analyzed eight dipstick tests using three URiSCAN devices. The results were compared to those of the tests performed using three Roche analyzers. The results of leukocyte and erythrocyte screens were compared to those obtained using manual microscopy. Protein, glucose, pH, and specific gravity (SG) assays p
We investigated the relationships between demographics, lifestyle characteristics, and serum total prostate specific antigen (PSA) concentration and examined the population-based distribution of total PSA by age among 2,246 Korean men with a median age of 45 years. We obtained data about demographic and lifestyle characteristics based on self-reporting using a questionnaire. We also performed physical examinations, anthropometric measurements, and biochemical measurements. The PSA concentration
Our results suggest that ESR1 gene polymorphisms may be associated with dysmenorrhea.
The diagnostic accuracy of the reverse and ECDC algorithms using the ECLIA as a first-line screening test was superior to that of the traditional algorithm.
Although cytology screening has reduced the incidence and mortality rate of cervical cancer significantly, its usefulness is limited to samples from the site of the lesion, resulting in its low sensitivity and unsuitability for use in medical checkups. The purpose of the present study was to evaluate the prevalence of HPV infection using genotype distribution and to analyze the correlation of the HPV DNA test results with cytological results. We also evaluated the benefits of quantitative inform
The cervical cancer screening guidelines suggest that early detection of HPV16 and HPV18 is helpful for identifying women with cervical intraepithelial neoplasia (CIN) grade two or higher. We comparatively evaluated three HPV DNA assays, Roche Cobas HPV, RFMP HPV PapilloTyper, and Hybrid Capture 2 (HC2). A total of 861 cervical swab samples from women over 30 years of age were classified into two groups, that is, high grade squamous intraepithelial lesion (HSIL) and non-HSIL, according to cervic
Research Areas
Dive deeper into Hee Yeon Woo's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.