Skip to main content

Jae Hyup Lee

Seoul National University · Medicine

About the Lab

Professor Jae Hyup Lee's research lab specializes in spinal biomaterials and orthopedic regenerative medicine, focusing on the development and evaluation of advanced bone graft substitutes, bioactive ceramics, and implant coatings to enhance spinal fusion outcomes. The lab investigates the biological and mechanical interactions between implants—such as PEEK and calcium phosphate-based materials—and host bone, with particular emphasis on improving osseointegration, reducing complications like cage subsidence, and optimizing fusion in osteoporotic or compromised bone. Key research directions include biomimetic materials, surface engineering of spinal implants, and the impact of patient-related factors (e.g., smoking, bone mineral density) on spinal fusion success.

spinal fusionbone graft substitutesbioactive ceramicsimplant integrationosteoporosis

Research Overview

Papers
265
Total Citations
4,648
Papers (5y)
26
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
26total
2022
2023
2024
2025
2026
Citations per year (5y)
162total
20222023202420252026

Selected Papers

15
1
Article|215 citations·2012
In vitro and in vivo evaluation of the bioactivity of hydroxyapatite-coated polyetheretherketone biocomposites created by cold spray technology
Jae Hyup Lee, Hae Lin Jang, Kyung Mee Lee, Hae-Ri Baek, Kyoungsuk Jin, Kug Sun Hong, Jun Hong Noh, Hyun-Kyung Lee
SJR Q1Acta Biomaterialia
Biomedical EngineeringEngineering
2
Article|188 citations·2015
The Correlation Between Cage Subsidence, Bone Mineral Density, and Clinical Results in Posterior Lumbar Interbody Fusion
Kyu Won Oh, Jae Hyup Lee, Ji Ho Lee, Do-Yoon Lee, Hee Jong Shim
SJR Q1Clinical Spine Surgery A Spine Publication

STUDY DESIGN: A retrospective review of prospectively collected radiographic and clinical data. OBJECTIVE: This study aims to investigate the relationship between cage subsidence and bone mineral density (BMD), and to reveal the clinical implications of cage subsidence. SUMMARY OF BACKGROUND DATA: Posterior lumbar interbody fusion (PLIF) has become one of the standard treatment modality for lumbar degenerative disease. However, cage subsidence might result in recurrent foraminal stenosis and det

Pathology and Forensic MedicineMedicine
3
Article|134 citations·2015
In Vitro and In Vivo Evaluation of Whitlockite Biocompatibility: Comparative Study with Hydroxyapatite and β‐Tricalcium Phosphate
Hae Lin Jang, Guang Bin Zheng, Jungha Park, Hwan Kim, Hae‐Ri Baek, Hye Kyoung Lee, Keunho Lee, Heung Nam Han, Choon‐Ki Lee, Nathaniel S. Hwang, Jae Hyup Lee, Ki Tae Nam
SJR Q1Advanced Healthcare Materials

Biomimicking ceramics have been developed to induce efficient recovery of damaged hard tissues. Among them, calcium phosphate-based bioceramics have been the most widely used because of their similar composition with human hard tissue and excellent biocompatibilities. However, the incomplete understanding of entire inorganic phases in natural bone has limited the recreation of complete bone compositions. In this work, broad biomedical evaluation of whitlockite (WH: Ca18Mg2(HPO4)2(PO4)12), which

Biomedical EngineeringEngineering
4
Article|83 citations·2010
Fusion Rates and Subsidence of Morselized Local Bone Grafted in Titanium Cages in Posterior Lumbar Interbody Fusion Using Quantitative Three-Dimensional Computed Tomography Scans
Jae Hyup Lee, Do-Whan Jeon, Suk-Jae Lee, Bong‐Soon Chang, Choon‐Ki Lee
SJR Q1Spine

The ratio of fused area of local bone inside cages at regions exposed to endplates was <50%, which is insufficient for physiologic load transmission. The authors recommend that additional bone should be grafted into the disc space or new bone bonding interbody spacer should be considered.

Pathology and Forensic MedicineMedicine
5
Article|64 citations·2015
Cold-spray coating of hydroxyapatite on a three-dimensional polyetheretherketone implant and its biocompatibility evaluated byin vitroandin vivominipig model
Jae Hyup Lee, Hae Lin Jang, Kyung Mee Lee, Hae-Ri Baek, Kyoungsuk Jin, Jun Hong Noh
SJR Q2Journal of Biomedical Materials Research Part B Applied Biomaterials

PEEK is a bioinert material that does not chemically bind to native bone tissue and thus formation of natural bone-like hydroxyapatite (HA) coating layer on PEEK has been an important challenge to improve biocompatibility and to preserve mechanical property of PEEK. Among various coating techniques, cold-spray coating method is suitable to form stable HA coating layer on PEEK while maintaining their chemical properties, because it can be conducted in relatively low-temperature range. Therefore,

Biomedical EngineeringEngineering
6
Article|61 citations·2021
The influence of smoking and alcohol on bone healing: Systematic review and meta-analysis of non-pathological fractures
Bin Xu, David Anderson, Eun-Sun Park, Lingxiao Chen, Jae Hyup Lee
SJR Q1EClinicalMedicineOA

BACKGROUND: We aimed to comprehensively evaluate the associations between (i) smoking, (ii) preoperative smoking cessation time, (iii) nicotine replacement therapy (NRT), (iv) vaping, and (v) alcohol consumption and non-pathological fracture healing in adult patients. We also assessed the impacts of preoperative smoking cessation time, NRT, and vaping on wound healing and wound complications after any sort of surgery. METHODS: We searched the MEDLINE, Embase, Cochrane CENTRAL, CINAHL, and AMED e

Endocrinology, Diabetes and MetabolismMedicine
7
Article|60 citations·2011
The First Clinical Trial of Beta-Calcium Pyrophosphate as a Novel Bone Graft Extender in Instrumented Posterolateral Lumbar Fusion
Jae Hyup Lee, Bong‐Soon Chang, Ul-Oh Jeung, Kunwoo Park, Min‐Seok Kim, Choon‐Ki Lee
SJR Q1Clinics in Orthopedic SurgeryOA

β-CPP combined with an autograft is as effective as autologous bone for grafting during instrumented posterolateral spinal fusion. These findings suggest that β-CPP bone chips can be used as a novel bone graft extender for short-segment posterolateral spinal fusion.

Pathology and Forensic MedicineMedicine
8
Article|58 citations·2011
Fusion rates of a morselized local bone graft in polyetheretherketone cages in posterior lumbar interbody fusion by quantitative analysis using consecutive three-dimensional computed tomography scans
Jae Hyup Lee, Jae Hyup Lee, Ji-Ho Lee, Ji-Ho Lee, Jaewoo Park, Hye Soo Lee
SJR Q1The Spine Journal
Pathology and Forensic MedicineMedicine
9
Article|55 citations·2004
Biomechanical and histomorphometric study on the bone–screw interface of bioactive ceramic-coated titanium screws
Jae Hyup Lee, Hyun‐Seung Ryu, Dongsoo Lee, Kug Sun Hong, Bong‐Soon Chang, Choon‐Ki Lee
SJR Q1Biomaterials
Biomedical EngineeringEngineering
10
Article|52 citations·2020
BMP-2 and hMSC dual delivery onto 3D printed PLA-Biogel scaffold for critical-size bone defect regeneration in rabbit tibia
Shi Huan Han, Misun Cha, Yuan Jin, Kyung-Mee Lee, Jae Hyup Lee
SJR Q2Biomedical Materials

3D printing technology has various advantages, and the incorporation of bioactive substances into the 3D printed scaffold provides the biological and architectural characteristics of the scaffolds, which is very important for obtaining a good osseointegration effect. In this relation, this study prepared a novel porous hollow cage poly(lactic acid) (PLA) 3D printed scaffold and combined recombinant human bone morphogenetic protein-2 (rhBMP-2) and/or mesenchymal stem cells (MSCs) with Biogel comp

Biomedical EngineeringEngineering
11
Article|52 citations·2016
Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion
Jae Hyup Lee, Chang-Bae Kong, Jae Jun Yang, Hee-Jong Shim, Ki Hyoung Koo, Jeehyoung Kim, Choon‐Ki Lee, Bong‐Soon Chang
SJR Q1The Spine JournalOA

BACKGROUND CONTEXT: glass ceramics spacer generates chemical bonding to adjacent bones with high mechanical stability to produce a union with the end plate, and ultimately stability. PURPOSE: glass ceramics with a titanium cage that is widely used for posterior lumbar interbody fusion (PLIF) surgery in the clinical field. STUDY DESIGN/SETTING: This is a prospective, stratified randomized, multicenter, single-blinded, comparator-controlled non-inferiority trial. PATIENT SAMPLE: The present study

Pathology and Forensic MedicineMedicine
12
Article|49 citations·2012
Comparative study of fusion rate induced by different dosages of Escherichia coli–derived recombinant human bone morphogenetic protein-2 using hydroxyapatite carrier
Jae Hyup Lee, Chang Hun Yu, Jae Jun Yang, Hae‐Ri Baek, Kyung-Mee Lee, Taeyoung Koo, Bong‐Soon Chang, Choon‐Ki Lee
SJR Q1The Spine Journal
Biomedical EngineeringEngineering
13
Article|48 citations·2014
Comparison of radiological and clinical results of balloon kyphoplasty according to anterior height loss in the osteoporotic vertebral fracture
Jae Hyup Lee, Dong‐Oh Lee, Jiho Lee, Ji-Ho Lee, Ji-Ho Lee, Hyeong-Seok Lee
SJR Q1The Spine Journal
SurgeryMedicine
14
Article|48 citations·2008
A prospective consecutive study of instrumented posterolateral lumbar fusion using synthetic hydroxyapatite (Bongros®‐HA) as a bone graft extender
Jae Hyup Lee, Chang Ju Hwang, Byung‐Wook Song, Ki‐Hyung Koo, Bong‐Soon Chang, Choon‐Ki Lee
SJR Q1Journal of Biomedical Materials Research Part A

A prospective, single institution, clinical case-matched, radiographic study was undertaken. Thirty-two patients underwent posterior lumbar interbody fusion with cages containing laminectomized bone chips and posterolateral lumbar fusion with pedicle screws. Autogenous bone graft (3 mL) plus 3 mL of hydroxyapatite was placed in one side of a posterolateral gutter, and 6 mL of autogenous iliac bone graft was placed on the other side. Bony union, volumes of fusion mass, and bone absorption rates w

Pathology and Forensic MedicineMedicine
15
Article|44 citations·2013
Fabrication and Evaluation of Porous Beta‐Tricalcium Phosphate/Hydroxyapatite (60/40) Composite as a Bone Graft Extender Using Rat Calvarial Bone Defect Model
Jae Hyup Lee, Mi Young Ryu, Hae‐Ri Baek, Kyung Mee Lee, Jun-Hyuk Seo, Hyun-Kyung Lee
SJR Q2The Scientific World JOURNALOA

Beta-tricalcium phosphate ( β -TCP) and hydroxyapatite (HA) are widely used as bone graft extenders due to their osteoconductivity and high bioactivity. This study aims to evaluate the possibility of using porous substrate with composite ceramics ( β -TCP: HA = 60% : 40%, 60TCP40HA) as a bone graft extender and comparing it with Bio-Oss. Interconnectivity and macroporosity of β -TCP porous substrate were 99.9% and 83%, respectively, and the macro-porosity of packed granule after crushing was 69%

Biomedical EngineeringEngineering

Research Areas

Biomedical EngineeringSurgeryPathology and Forensic MedicineOrthopedics and Sports MedicineLawMolecular Biology

Dive deeper into Jae Hyup Lee's research on Nubint