Skip to main content

Jae-Wook Park

Yonsei University · Medicine

About the Lab

Professor Jae-Wook Park's research lab specializes in interventional electrophysiology, with a primary focus on optimizing catheter ablation strategies for atrial fibrillation. The lab investigates hemodynamic factors—such as left atrial pressure and stiffness—that influence ablation outcomes, as well as long-term renal and rhythm outcomes following ablation. They also explore advanced ablation technologies, including cryoballoon and high-power short-duration radiofrequency ablation, to improve procedural efficacy and safety. Their work integrates clinical outcomes with physiological and hemodynamic monitoring to refine patient selection and treatment protocols.

catheter ablationatrial fibrillationleft atrial pressurepulmonary vein isolationrhythm outcomes

Research Overview

Papers
93
Total Citations
740
Papers (5y)
58
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
58total
2022
2023
2024
2025
2026
Citations per year (5y)
221total
20222023202420252026

Selected Papers

15
1
Article|52 citations·2020
Mechanisms of Long-Term Recurrence 3 Years After Catheter Ablation of Atrial Fibrillation
Je‐Wook Park, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Hui‐Nam Pak
SJR Q1JACC. Clinical electrophysiologyOA
Cardiology and Cardiovascular MedicineMedicine
2
Article|49 citations·2019
Atrial Fibrillation Catheter Ablation Increases the Left Atrial Pressure
Je‐Wook Park, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Chun Hwang, Hui‐Nam Pak
SJR Q1Circulation Arrhythmia and ElectrophysiologyOA

Background: We previously reported that a high left atrial (LA) pressure is associated with LA stiffness and poor rhythm outcomes after de novo catheter ablation of atrial fibrillation. Herein, we investigated whether radiofrequency catheter ablation generally changes the LA pressure among patients undergoing repeat procedures. Methods: Among 1848 patients who underwent atrial fibrillation catheter ablation, we measured the LA pressure during sinus rhythm in 1687 patients before the de novo abla

Cardiology and Cardiovascular MedicineMedicine
3
Article|44 citations·2020
Electrical Posterior Box Isolation in Persistent Atrial Fibrillation Changed to Paroxysmal Atrial Fibrillation
Hui‐Nam Pak, Junbeom Park, Je‐Wook Park, Song-Yi Yang, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Jong‐Il Choi, Boyoung Joung, Moon‐Hyoung Lee, Young‐Hoon Kim, Jaemin Shim
SJR Q1Circulation Arrhythmia and ElectrophysiologyOA

Background: Persistent atrial fibrillation (AF) can change to paroxysmal AF after antiarrhythmic drug medication and cardioversion. We investigated whether electrical posterior box isolation (POBI) may improve rhythm outcome of catheter ablation in those patient groups. Methods: We prospectively randomized 114 patients with persistent AF to paroxysmal AF (men, 75%; 59.8±9.9 years old) to circumferential pulmonary vein isolation (CPVI) alone group (n=57) and additional POBI group (n=57). Primary

Cardiology and Cardiovascular MedicineMedicine
4
Article|43 citations·2019
Five‐Year Change in the Renal Function After Catheter Ablation of Atrial Fibrillation
Je‐Wook Park, Pil‐Sung Yang, Han‐Joon Bae, Song‐Yi Yang, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Hui‐Nam Pak
SJR Q1Journal of the American Heart AssociationOA

Background Although it has been reported that renal function can improve after catheter ablation of atrial fibrillation ( AF ), long‐term changes in renal function and its relationship to rhythm outcomes have not yet been evaluated. We explored the 5‐year change in estimated glomerular filtration rate ( eGFR ) in AF patients depending on medical therapy and catheter ablation. Methods and Results Among 1963 patients who underwent AF catheter ablation and 14 056 with AF under medical therapy in th

Cardiology and Cardiovascular MedicineMedicine
5
Article|42 citations·2011
Sensorless Control of Brushless DC Motors With Torque Constant Estimation for Home Appliances
Je‐Wook Park, Seon-Hwan Hwang, Jang-Mok Kim
SJR Q1IEEE Transactions on Industry Applications

A new sensorless control algorithm for brushless dc motors (BLDCMs) is proposed in this paper. The torque constant of a BLDCM is used as a reference signal for position detection because it is constant during the entire speed range and can be estimated by calculating the ratio of the back electromotive force (EMF) to the rotor speed. By using both a disturbance observer and the torque constant estimation error, the rotor speed can be obtained. The back EMF can be easily obtained from the voltage

Electrical and Electronic EngineeringEngineering
6
Article|39 citations·2022
Sex difference in atrial fibrillation recurrence after catheter ablation and antiarrhythmic drugs
Yoon Jung Park, Je‐Wook Park, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Hui‐Nam Pak
SJR Q1HeartOA

OBJECTIVE: The risk of recurrence after atrial fibrillation (AF) catheter ablation (AFCA) is higher in women than in men. However, it is unknown whether a sex difference exists in antiarrhythmic drug (AAD) responsiveness among patients with recurrence. METHODS: Among 2999 consecutive patients (26.5% women, 58.3±10.9 years old, 68.1% paroxysmal AF) who underwent de novo AFCA, we compared and evaluated the sex differences in rhythm outcome in 1094 patients with recurrence and in 788 patients who s

Cardiology and Cardiovascular MedicineMedicine
7
Article|29 citations·2020
A mendelian randomization analysis: The causal association between serum uric acid and atrial fibrillation
Myunghee Hong, Je‐Wook Park, Pil‐Sung Yang, Inseok Hwang, Tae‐Hoon Kim, Hee Tae Yu, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Sun Ha Jee, Hui‐Nam Pak
SJR Q1European Journal of Clinical InvestigationOA

BACKGROUND: Observational studies have shown that high levels of serum uric acid (UA) were associated with atrial fibrillation (AF). However, the causal effect of urate on the risk of AF is still unknown. To clarify the potential causal association between UA and AF, we performed a Mendelian randomization (MR) analysis using genetic instrumental variables (IVs). MATERIALS AND METHODS: From the Korean GWAS dataset of 633 patients with AF (mean age 50.6 ± 7.8 years, 80.9% male, Yonsei AF Ablation

NephrologyMedicine
8
Article|29 citations·2021
Cryoballoon Versus High-Power, Short-Duration Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation
Hui‐Nam Pak, Je‐Wook Park, Song-Yi Yang, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Hee Tae Yu, for the CRAFT Investigators
SJR Q1Circulation Arrhythmia and ElectrophysiologyOA

Background: The efficacy of cryoballoon pulmonary vein isolation (Cryo-PVI) is equivalent to that of radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation (AF). We aimed to compare the efficacy and safety profile of Cryo-PVI and high-power, short-duration (HPSD) radiofrequency catheter ablation (RFCA) in patients with AF. Methods: We prospectively randomized 314 patients with paroxysmal AF (men, 71.3%; 59.9±10.9 years old) to either the Cryo-PVI group (n=156) or

Cardiology and Cardiovascular MedicineMedicine
9
Article|27 citations·2023
Late recurrence of atrial fibrillation 5 years after catheter ablation: predictors and outcome
Sung Hwa Choi, Hee Tae Yu, Daehoon Kim, Je‐Wook Park, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Chun Hwang, Hui‐Nam Pak
SJR Q1EP EuropaceOA

AIMS: Atrial fibrillation (AF) is a chronic progressive disease that continuously recurs even after successful AF catheter ablation (AFCA). We explored the mechanism of long-term recurrence by comparing patient characteristics and redo-ablation findings. METHODS AND RESULTS: Among the 4248 patients who underwent a de novo AFCA and protocol-based rhythm follow-up at a single centre, we enrolled 1417 patients [71.7% male, aged 60.0 (52.0-67.0) years, 57.9% paroxysmal AF] who experienced clinical r

Cardiology and Cardiovascular MedicineMedicine
10
Article|21 citations·2019
Trends and Outcome of Catheter Ablation of Atrial Fibrillation Over 9 Years ― Focus on Empirical Extra-Pulmonary Vein Ablation ―
Je‐Wook Park, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Jong‐Youn Kim, Boyoung Joung, Moon‐Hyoung Lee, Hui‐Nam Pak
SJR Q1Circulation JournalOA

Over the 9 years the extra-PV LA ablation and 1-year recurrence rates in the AF ablation cohort decreased, in part due to improved catheter technology.

Cardiology and Cardiovascular MedicineMedicine
11
Article|19 citations·2021
Clinical Outcomes of Computational Virtual Mapping-Guided Catheter Ablation in Patients With Persistent Atrial Fibrillation: A Multicenter Prospective Randomized Clinical Trial
Yong‐Soo Baek, Oh‐Seok Kwon, Byounghyun Lim, Song-Yi Yang, Je‐Wook Park, Je‐Wook Park, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Dae‐Hyeok Kim, Moon‐Hyoung Lee
SJR Q1Frontiers in Cardiovascular MedicineOA

Background: Clinical recurrence after atrial fibrillation catheter ablation (AFCA) still remains high in patients with persistent AF (PeAF). We investigated whether an extra-pulmonary vein (PV) ablation targeting the dominant frequency (DF) extracted from electroanatomical map–integrated AF computational modeling improves the AFCA rhythm outcome in patients with PeAF. Methods: In this open-label, randomized, multi-center, controlled trial, 170 patients with PeAF were randomized at a 1:1 ratio to

Cardiology and Cardiovascular MedicineMedicine
12
Article|14 citations·2021
Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation
Je‐Wook Park, Song-Yi Yang, Min Kim, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Boyoung Joung, Moon‐Hyoung Lee, Hui‐Nam Pak
SJR Q1Frontiers in Cardiovascular MedicineOA

Introduction: Whereas, high-power short-duration (HPSD) radiofrequency (RF) ablation is generally used in atrial fibrillation (AF) catheter ablation (CA), its efficacy, safety, and influence on autonomic function have not been well established in a large population. This study compared HPSD-AFCA and conventional power (ConvP)-AFCA in propensity score matched-population. Methods: In 3,045 consecutive patients who underwent AFCA, this study included 1,260 patients (73.9% male, 59 ± 10 years old, 5

Cardiology and Cardiovascular MedicineMedicine
13
Article|11 citations·2022
Machine Learning-Predicted Progression to Permanent Atrial Fibrillation After Catheter Ablation
Je‐Wook Park, Oh‐Seok Kwon, Jaemin Shim, Inseok Hwang, Yun Gi Kim, Hee Tae Yu, Tae‐Hoon Kim, Jae‐Sun Uhm, Jong‐Youn Kim, Jong‐Il Choi, Boyoung Joung, Moon‐Hyoung Lee
SJR Q1Frontiers in Cardiovascular MedicineOA

Introduction We developed a prediction model for atrial fibrillation (AF) progression and tested whether machine learning (ML) could reproduce the prediction power in an independent cohort using pre-procedural non-invasive variables alone. Methods Cohort 1 included 1,214 patients and cohort 2, 658, and all underwent AF catheter ablation (AFCA). AF progression to permanent AF was defined as sustained AF despite repeat AFCA or cardioversion under antiarrhythmic drugs. We developed a risk stratific

Cardiology and Cardiovascular MedicineMedicine
14
Article|9 citations·2012
DC voltage balancing control of half-bridge PWM inverter for linear compressor
Je‐Wook Park, Jang-Mok Kim, Shin-Hyun Park, Kye-Lyong Kang, Tae-Uk Jung

This paper proposes a new single phase back-to-back PWM converter for the power supply of the single phase by using both a full-bridge PWM rectifier and a half-bridge PWM inverter. In addition, the balancing control algorithm of DC voltage for this topology is also proposed by controlling the current of the half-bridge inverter. With the full-bridge PWM rectifier and the half-bridge PWM inverter, AC/DC/AC operation can be carried out by using only a six-pack power module and two series DC capaci

Electrical and Electronic EngineeringEngineering
15
Article|6 citations·2014
Safe driving algorithm of the electric wheelchair with model following control
Je‐Wook Park, Won-Sang Im, Dong-Youn Kim, Jang-Mok Kim

The wheelchair motion has propulsion and rotation components and the x-y axis signals of the joystick also can be expressed as the control command of these components. Using this phenomenon, the torque distribution method of two driving wheels and the model following control algorithm based on the propulsion and the rotation model of the electric wheelchair is proposed. The proposed torque distribution method gives smooth and precise driving performance on the land because the torque references

Human-Computer InteractionComputer Science

Research Areas

Cardiology and Cardiovascular MedicineElectrical and Electronic EngineeringRadiology, Nuclear Medicine and ImagingEmergency MedicineEndocrinology, Diabetes and MetabolismNephrology

Dive deeper into Jae-Wook Park's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.