About the Lab
Professor Je-Kyun Park's research lab specializes in microfluidic technologies for biomedical applications, focusing on label-free, high-throughput cell and particle separation using innovative hydrodynamic and dielectrophoretic principles. The lab develops advanced microfluidic devices that leverage inertial focusing, hydrophoresis, and electric field manipulation to enable precise, automated, and pump-free sample preparation for point-of-care diagnostics. Key research directions include the design of low-shear, high-efficiency microfluidic systems for whole blood processing and the integration of magnetic nanoparticles and dielectrophoresis for sensitive biomolecular detection.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15We report a contraction-expansion array (CEA) microchannel device that performs label-free high-throughput separation of cancer cells from whole blood at low Reynolds number (Re). The CEA microfluidic device utilizes hydrodynamic field effect for cancer cell separation, two kinds of inertial effects: (1) inertial lift force and (2) Dean flow, which results in label-free size-based separation with high throughput. To avoid cell damages potentially caused by high shear stress in conventional inert
This paper describes a novel microfluidic immunoassay utilizing binding of superparamagnetic nanoparticles to beads and deflection of these beads in a magnetic field as the signal for measuring the presence of analyte. The superparamagnetic 50 nm nanoparticles and fluorescent 1 microm polystyrene beads are immobilized with specific antibodies. When target analytes react with the polystyrene beads and superparamagnetic nanoparticles simultaneously, the superparamagnetic nanoparticles can be attac
We propose a new hydrophoretic method for continuous blood cell separation using a microfluidic device composed of slanted obstacles and filtration obstacles. The slanted obstacles have a larger height and gap than the particles in order to focus them to a sidewall by hydrophoresis. In the successive structure, the height and gap of the filtration obstacles with a filtration pore are set between the diameters of small and large particles, which defines the critical separation diameter. According
This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane)(PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA
Microfluidic technologies offer a number of advantages for sample preparation in point-of-care testing (POCT), but the requirement for complicated external pumping systems limits their wide use. To facilitate sample preparation in POCT, various methods have been developed to operate microfluidic devices without complicated external pumping systems. In this review, we introduce an overview of user-friendly microfluidic devices for practical sample preparation in POCT, including self- and hand-ope
We report a microfluidic separation and sizing method of microparticles with hydrophoresis--the movement of suspended particles under the influence of a microstructure-induced pressure field. By exploiting slanted obstacles in a microchannel, we can generate a lateral pressure gradient so that microparticles can be deflected and arranged along the lateral flows induced by the gradient. Using such movements of particles, we completely separated polystyrene microbeads with 9 and 12 microm diameter
This paper describes a new label-free cell separation method using a magnetic repulsion force resulting from the magnetic susceptibility difference between cells and a paramagnetic buffer solution in a microchannel. The difference in the magnetic forces acting on different-sized cells is enhanced by adjusting the magnetic susceptibility of the surrounding medium, which depends on the concentration of paramagnetic salts, such as biocompatible gadolinium diethylenetriamine pentaacetic acid (Gd-DTP
We report a contraction-expansion array (CEA) microchannel that allows three-dimensional hydrodynamic focusing with a single sheath flow in a single-layer device. The CEA microchannel exploits centrifugal forces acting on fluids travelling along the contraction and expansion regions of the microchannel. Around an entrance of the contraction region, the centrifugal forces induce a secondary flow field where two counter-rotating vortices enable to envelop a sample flow with a sheath flow in three
This paper presents a pressed paper-based dipstick that enables detection of foodborne pathogens with multistep reactions by exploiting the delayed fluid flow and channel partition formation on nitrocellulose (NC) membrane. Fluid behaviors are easily modified by controlling the amount of pressure and the position of pressed region on the NC membrane. Detection region of the dipstick is optimized by controlling flow rate and delayed time based on Darcy's law. All the reagents required for assay a
Extraordinary advances in lab on a chip systems have been made on the basis of the development of micro/nanofluidics and its fusion with other technologies based on electrokinetics and optics. Optoelectrofluidic technology, which has been recently introduced as a new manipulation scheme, allows programmable manipulation of particles or fluids in microenvironments based on optically induced electrokinetics. Herein, the behaviour of particles or fluids can be controlled by inducing or perturbing e
This paper presents a microfluidic device for sheathless focusing of microbeads and blood cells based on a hydrophoretic platform comprising a V-shaped obstacle array (VOA). The VOA generates lateral pressure gradients that induce helical recirculations. Following the focusing flow particles passing through the VOA are focused in the center of the channel. In the device, the focusing pattern can be modulated by varying the gap height of the VOA. To achieve complete focusing within 4.4% coefficie