Kyu-Nam Park
Yonsei University · Psychology
About the Lab
Professor Kyu-Nam Park's research lab specializes in neuromuscular and musculoskeletal rehabilitation, focusing on motor control, muscle activation patterns, and spinal stability. The lab investigates the reliability of clinical measurement tools, such as goniometers, smartphone applications, and dynamometers, in assessing joint motion and muscle strength. Key research directions include surface electromyography (sEMG) analysis during therapeutic exercises, lumbar stabilization exercises, and the role of deep stabilizing muscles like the multifidus and trapezius in spinal and postural control. The lab also explores the impact of different exercise conditions and support surfaces on muscle activity in both healthy individuals and patients with low back pain or stroke.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the “Clinometer + bubble level”, a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotatio
The aim of this study was to determine the muscle activity of the abdominalis and erector spinae during bridging and unilateral bridging exercises on the firm surface, the sit-fit, and the foam roll. Eighteen healthy young subjects were recruited for this study. Surface electromyographic (EMG) activities were recorded from the both sides of the rectus abdominalis, external obliques, internal obliques, and erector spinae muscles during bridging and unilateral bridging exercises. A one-way repeate
The purpose of this study was to compare electromyography (EMG) activity for the middle and lower trapezius muscle according to various shoulder abduction angles. Thirty healthy male subjects were recruited for this study. Each subject performed three repetitions of horizontal abduction at 75°, 90°, 125°, 160°, and 180° of shoulder abduction angle in a prone position. Surface EMG activity was recorded from the middle and lower trapezius while the subjects held for five seconds at a predetermined
The lumbar multifidus muscle, which can be separated into deep fascicles (DM) and superficial fascicles (SM), is important for lumbar segmental stability. However, no previous studies have investigated the effect of lumbar stabilization exercises on the thickness of DM and SM. Thus, the purpose of this study was to assess DM thickness after three different lumbar segmental stabilization exercises. In total, 30 healthy male participants were recruited and randomly assigned to one of three exercis
The purpose of this study was to examine contraction of abdominal muscles on surface electromyographic (EMG) activity of superficial cervical flexors, rib cage elevation and angle of craniocervical flexion during deep cervical flexion exercise in supine position. Fifteen healthy subjects were participated for this study. All subjects performed deep cervical flexion exercise with two methods. The positions of two methods were no volitional contraction of abdominal muscles in hook-lying position w
The purpose of this study was to assess the agreement of manual muscle testing (MMT) and test-retest reliability of a hand held dynamometer for the posterior gluteus medius muscle, with and without lumbar stabilization, using a pressure biofeedback unit for patients with low back pain. The pressure biofeedback unit was used to minimize the substitute motion of the lumbopelvic region during hip abduction in patients lying on their side. Fifteen patients with low back pain participated in this stu
Here, we present the spectroscopic ellipsometry investigation of synthetically grown wafer-scale twodimensional (2D) MoS2 and WSe2 films to access quality and thickness uniformity. MoS2 and WSe2 samples were grown by chemical vapor deposition and atomic layer deposition, respectively. Complex dielectric function (ε ¼ ε1 þ iε2) and thickness information of these 2D films were extracted from the measured data using multilayer optical calculations. Broad spectral range (1.2e6 eV) and multiple angle
The purpose of this study was to measure intrarater and interrater reliability of a portable digital pressure algometer. Fifty healthy subjects were recruited for this study. Pressure pain thresholds of splenius capitis, levator scapular, and upper trapezius muscles were measured using by FPK algometer and portable digital pressure algometer. Three trials were done on each subject by two examiners. Intraclass correlation coefficients (ICCs) were used to determine the reliability of each measure.
The purpose of this study was to identify the effects of two types of stretching extensor carpi radialis on the visual analog scale (VAS), pressure-pain thresholds (PPTs), grip strength (GS), and strength of wrist extensor (SWE) in patients with lateral epicondylalgia. Sixteen patients with lateral epicondylalgia were recruited for this study and randomly assigned to two groups; the conventional stretching group (CS) and the stretching of proximal functional massage group (PFM); the VAS, PPTs, G
The aim of this study was to compare electromyography activity for long and lateral heads of triceps brachii muscle according to forearm positions during different triceps strengthening exercises. The muscle activities for long and lateral head of triceps brachii were measured by surface electromyography. Fifteen healthy volunteers participated for this study and performed elbow extension in three different elbow extension exercises (elbow extension in a supine position; EES, elbow extension wit
Stiffness of the posterior deltoid is as a causative factor in the limited range of glenohumeral horizontal adduction and various other shoulder pathologies including shoulder impingement syndrome, frozen shoulder, and humerus anterior glide syndrome. The purpose of this study was to compare the effects of two techniques (soft tissue massage and cross-body stretch) on increasing the range of horizontal adduction. Thirty-two subjects with a 10° or greater difference between the right and left sid
The purpose of this study was to compare the immediate effects of upper trapezius muscle stretching in more tensed position (MTP) and less tensed position (LTP) on the change of range of motion (ROM) for neck rotation, and the ROM for conjunct neck motions at end-range of neck rotation toward the painful side in patients with unilateral neck pain. Eighteen patients with unilateral neck pain were recruited for the study’s MTP group, and 18 age-, weight- and gender-matched patients with unilateral
The purpose of this study was to identify the effects of manual facilitation and a stick on lumbar and hip joint flexion angles in subject with lumbar flexion syndrome during forward bending from a sitting position. Fifteen subjects with lumbar flexion syndrome were recruited for this study. As a pretest, all subjects performed three repetitions of bending the trunk forward until the tips of their fingers touched the target bar. After this pretest, the subjects practiced the forward bending of t
Ely’s test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely’s test. The aim of this study was to examine the reliability of Ely’s test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen pa
Research Areas
Dive deeper into Kyu-Nam Park's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.