Kyung-Hun Kim
Hanyang University · Medicine
About the Lab
Professor Kyung-Hun Kim's research lab specializes in advanced materials development for energy applications and clinical anesthesiology, with a strong focus on thermoelectric materials and airway management devices. The lab investigates nanostructured oxides such as Al- and Ni-doped ZnO to enhance thermoelectric performance through microstructural control and defect engineering. In clinical research, the lab explores ultrasound-guided nerve blocks and advanced airway devices like the I-gel and Glidescope to improve patient safety and procedural outcomes in anesthesia. The integration of materials science and clinical anesthesiology defines the lab’s unique interdisciplinary approach.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15M‐doped zinc oxide (ZnO) (M=Al and/or Ni) thermoelectric materials were fully densified at a temperature lower than 1000°C using a spark plasma sintering technique and their microstructural evolution and thermoelectric characteristics were investigated. The addition of Al 2 O 3 reduced the surface evaporation of pure ZnO and suppressed grain growth by the formation of a secondary phase. The addition of NiO promoted the formation of a solid solution with the ZnO crystal structure and caused sever
BACKGROUND: The greater occipital nerve (GON) block has been frequently used for different types of headache, but performed with rough estimates of anatomic landmarks. Our study presents the values of the anatomic parameters and estimates the effectiveness of the ultrasound-guided GON blockade. METHODS: The GON was detected using ultrasound technique and distance from external occipital protuberance (EOP) to GON, from GON to occipital artery and depth from skin to GON was measured in volunteers.
BACKGROUND: The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-g
BACKGROUND: Although acute tolerance to opioids, especially to remifentanil, has been demonstrated consistently in animal studies, the results of clinical trials in humans are controversial. The aim of this study was to determine whether intraoperative infusions of remifentanil used as an adjuvant in general anesthesia result in acute tolerance, an event manifested by increased postoperative pain and a higher opioid requirement than usual. METHODS: Sixty patients who underwent surgery under gene
BACKGROUND: The Glidescope® videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. METHODS: Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computer-generated numbers. Tracheal intubation was attempted by an anesthesiologist with extensive experience using th
An effect-site concentration of remifentanil of 2 ng/mL provides excellent conditions for insertion of the CobraPLA on the first attempt with minimal hemodynamic perturbations and a shorter duration of apnea.
Laparoscopy is a recent widely used procedure when operating gynecologic diseases. Position change, increased intra-abdominal pressure or pneumoperitonium can cause pleural effusion during the laparoscopic surgery. On the other hand, disease condition such as ovarian tumor is also associated with pleural effusion. Several ovarian tumors with pleural effusion and/or ascites are known as pseudo-Meigs syndrome [1]. We present such a case of right massive hydrothorax in a female patient with serous
Awareness with recall after general anesthesia is a relatively infrequent occurrence and this awareness is often associated with significant adverse psychological sequelae, including posttraumatic stress disorder. The occurrence of awareness is often the consequence of the light anesthetic techniques with using minor anesthetic agents. Because the locking lever of the Penlon Sigma Delta Anesthetic vaporizer (sevoflurane) was at the unlock position, disconnection happened between the anesthetic m
Background: Nitrous oxide is generally avoided in order to prevent either hypoxia or graft dislodgment during tympanoplasty. The aim of this study was to investigate the effect of nitrous oxide on the bispectral index during sevoflurane anesthesia at the anesthetic dose. Methods: The bispectral index was continually measured during nitrous oxide-oxygen-sevoflurane anesthesia, discontinuation of nitrous oxide and the reintroduction of nitrous oxide. Results: The bispectral index of nitrous oxid
Research Areas
Dive deeper into Kyung-Hun Kim's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.