Skip to main content
QUICK REVIEW

[Paper Review] A comparison of proton ranges in complex media using GATE/Geant4, MCNP6 and FLUKA

Jarle Rambo Sølie, Helge Egil Seime Pettersen|arXiv (Cornell University)|Aug 2, 2017
Radiation Therapy and DosimetryMedicine13 references4 citations
TL;DR

This study compares proton range predictions in complex media using three Monte Carlo radiation transport codes—GATE/Geant4, MCNP6, and FLUKA—against semi-empirical data. The codes show strong agreement in mean range, lateral spread, and nuclear interaction losses, with minor discrepancies in lateral beam spreading (GATE/Geant4) and a slight underestimation of range in water by MCNP6, validating their use in proton therapy and CT detector design.

ABSTRACT

The Monte Carlo (MC) simulation method is a powerful tool for radiation physicists, and several general-purpose software packages are commonly applied in a myriad of different radiation physics fields today. In medical physics, charged particle detectors for proton Computed Tomography are under development, a modality introduced in order to increase the accuracy of proton radiation therapy. MC simulations are helpful during the development and optimization phase of such detector systems. In order to justify the usage of MC for such purposes, the simulation output must be validated against experimental or theoretical data, or even cross-checked between different MC software packages. In this study, we compare three general-purpose MC software packages (GATE/Geant4, MCNP6 and FLUKA) with respect to how they predict the spatial distribution of the stopping position of protons. They are compared to each other and to semi-empirical data, using the mean proton range, the longitudinal and lateral variation of individual proton ranges, and the fraction of primary protons lost to nuclear interactions. This comparison is performed in two homogeneous materials and in a detector geometry designed for proton Computed Tomography. The three MC software packages agree well, and sufficiently reproduce the semi-empirical data. Some discrepancies are observed, such as less lateral beam spreading in GATE/Geant4, and a small deficiency in the MCNP6 proton range in water: This is consistent with previously published data. Due to the general agreement, the choice of simulation framework may be made on personal preferences. It is important to note that the choice of physics packages, simulation parameter settings and material definitions are important aspects when performing MC simulations, both during the preparation, execution and interpretation of the simulation results.

Motivation & Objective

  • To evaluate the consistency of proton range predictions across three major Monte Carlo codes: GATE/Geant4, MCNP6, and FLUKA.
  • To validate simulation results against semi-empirical data for proton stopping ranges in heterogeneous media.
  • To assess the impact of code-specific physics models and simulation parameters on proton range and beam spread predictions.
  • To support the reliability of Monte Carlo simulations in the design and optimization of proton Computed Tomography detectors.
  • To provide guidance on code selection based on performance, accuracy, and user preference in medical physics applications.

Proposed method

  • Simulated proton transport through homogeneous materials (water and PMMA) and a proton CT detector geometry using GATE/Geant4, MCNP6, and FLUKA.
  • Employed standard physics lists and default simulation parameters for each code to ensure fair comparison.
  • Tracked individual proton ranges to compute mean range, longitudinal and lateral spread, and fraction of protons lost to nuclear interactions.
  • Compared simulation outputs directly with semi-empirical data derived from established proton stopping power relationships.
  • Analyzed discrepancies in beam spreading and range predictions across the three software packages.
  • Used consistent material definitions and particle source configurations across all simulations to isolate code-dependent differences.

Experimental results

Research questions

  • RQ1How do GATE/Geant4, MCNP6, and FLUKA compare in predicting the mean proton range in water and PMMA?
  • RQ2To what extent do the three codes reproduce the longitudinal and lateral spread of proton ranges in complex media?
  • RQ3What is the fraction of primary protons lost to nuclear interactions in each simulation framework?
  • RQ4How do the simulation results compare quantitatively with semi-empirical proton stopping power data?
  • RQ5Are there systematic differences in beam spread or range prediction that could affect detector design in proton CT?

Key findings

  • The three Monte Carlo codes—GATE/Geant4, MCNP6, and FLUKA—show strong agreement in predicting the mean proton range in both water and PMMA.
  • GATE/Geant4 exhibited less lateral beam spreading compared to MCNP6 and FLUKA, suggesting differences in multiple scattering modeling.
  • MCNP6 showed a small but consistent underestimation of the proton range in water, consistent with previously reported discrepancies.
  • All three codes reproduced the semi-empirical data for proton ranges within acceptable margins, validating their use for proton therapy and CT detector simulations.
  • The fraction of protons lost to nuclear interactions was comparable across all codes, indicating consistent treatment of nuclear interactions.
  • Despite minor differences, the overall agreement supports the reliability of any of the three codes for proton CT detector development, with code choice guided by user preference and configuration settings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.