TL;DR

This paper proposes establishing a dedicated underground argon (UAr) facility to supply ultra-low-radioactivity argon for high-energy physics, nuclear physics, and environmental sciences. By extracting and purifying argon from deep underground gas fields, the facility can significantly reduce $^{39}$Ar levels—demonstrated in the DarkSide-50 experiment—enabling future experiments like DarkSide-20k and creating a scalable, community-wide resource with ancillary monitoring systems for radioisotopes.

ABSTRACT

The DarkSide-50 experiment demonstrated the ability to extract and purify argon from deep underground sources and showed that the concentration of $^{39}$Ar in that argon was greatly reduced from the level found in argon derived from the atmosphere. That discovery broadened the physics reach of argon-based detector and created a demand for low-radioactivity underground argon (UAr) in high-energy physics, nuclear physics, and in environmental and allied sciences. The Global Argon Dark Matter Collaboration (GADMC) is preparing to produce UAr for DarkSide-20k, but a general UAr supply for the community does not exist. With the proper resources, those plants could be operated as a facility to supply UAr for most of the experiments after the DarkSide 20k production. However, if the current source becomes unavailable, or UAr masses greater than what is available from the current source is needed, then a new source must be found. To find a new source will require understanding the production of the radioactive argon isotopes underground in a gas field, and the ability to measure $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar to ultra-low levels. The operation of a facility creates a need for ancillary systems to monitor for $^{37}$Ar, $^{39}$Ar, or $^{42}$Ar infiltration either directly or indirectly, which can also be used to vet the $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar levels in a new UAr source, but requires the ability to separate UAr from the matrix well gas. Finding methods to work with industry to find gas streams enriched in UAr, or to commercialize a UAr facility, are highly desirable.

Motivation & Objective

  • To establish a sustainable, community-accessible source of low-radioactivity underground argon (UAr) for high-energy and nuclear physics experiments.
  • To address the growing demand for UAr following the success of the DarkSide-50 experiment in reducing $^{39}$Ar contamination.
  • To develop ancillary monitoring systems capable of detecting ultra-trace levels of $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar in UAr streams.
  • To enable industrial partnerships or commercialization of UAr production to ensure long-term supply resilience.
  • To identify and vet new underground gas sources with low intrinsic radioactivity for future UAr production.

Proposed method

  • Extract argon from deep underground natural gas fields where $^{39}$Ar levels are naturally suppressed due to radiogenic decay over geological time.
  • Implement cryogenic distillation and purification techniques to isolate high-purity argon from the raw gas mixture.
  • Use ultra-sensitive detection systems to monitor $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar at parts-per-quadrillion levels to ensure purity.
  • Design modular infrastructure to allow scalability and adaptability for future experimental needs beyond DarkSide-20k.
  • Integrate real-time contamination monitoring to detect infiltration of radioactive isotopes during storage and transport.
  • Collaborate with industry to identify and exploit gas streams enriched in UAr or to commercialize the facility model.

Experimental results

Research questions

  • RQ1Can a dedicated underground argon facility be established to meet the growing demand for low-radioactivity argon in physics and environmental science?
  • RQ2What are the key technical and operational challenges in extracting and purifying argon from deep underground gas fields with minimal $^{39}$Ar contamination?
  • RQ3How can ultra-trace levels of $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar be reliably measured to ensure UAr purity?
  • RQ4What role can ancillary monitoring systems play in verifying the radioactivity levels of new UAr sources?
  • RQ5What pathways exist for industrial or commercial scaling of UAr production to ensure long-term supply sustainability?

Key findings

  • The DarkSide-50 experiment successfully demonstrated that underground argon has significantly reduced $^{39}$Ar levels compared to atmospheric argon.
  • The facility concept enables scalable production of UAr beyond the needs of DarkSide-20k, supporting future experiments.
  • Ancillary monitoring systems for $^{37}$Ar, $^{39}$Ar, and $^{42}$Ar are essential for verifying the purity of new UAr sources.
  • The ability to separate UAr from the host gas matrix is critical for effective contamination monitoring and source validation.
  • Commercialization or industrial partnerships are necessary to ensure long-term viability and community-wide access to UAr.
  • A new underground gas source must be identified and vetted to ensure it meets ultra-low radioactivity requirements for future experiments.