Skip to main content
QUICK REVIEW

[Paper Review] A new method for direct rf power absorption studies in CMR materials and high T_c superconductors

S. Sarangi, S. V. Bhat|arXiv (Cornell University)|Mar 22, 2005
Physics of Superconductivity and MagnetismPhysics and Astronomy5 citations
TL;DR

This paper presents a novel self-resonant LC oscillator setup using a 74LS04 NOT gate to directly measure microwave power absorption in colossal magnetoresistive (CMR) and high-Tc superconducting materials. By monitoring current changes in the oscillator circuit when samples are placed in the coil's core, the system achieves high sensitivity (SNR = 10:1) for samples as small as 10⁻³ cm³, enabling automated, temperature- and field-tunable measurements from 4.2 K to 400 K and up to 1.4 T, validated on LSMO and YBCO samples.

ABSTRACT

The design, fabrication and performance of an apparatus for the measurement of direct rf power absorption in colossal magnetoresistive (CMR) and superconducting samples are described. The system consists of a self-resonant LC tank circuit of an oscillator driven by a NOT logic gate. The samples under investigation are placed in the core of the coil forming the inductance L and the absorbed power is determined from the measured change in the current supplied to the oscillator circuit. A customized low temperature insert is used to integrate the experiment with a commercial Oxford Instruments cryostat and temperature controller. The oscillator working in the rf range between 1 MHz to 25 MHz is built around an IC 74LS04. The temperature can be varied from 4.2 to 400 K and the magnetic field from 0 to 1.4 T. The apparatus is capable of measuring direct power absorption in CMR and superconducting samples of volume as small as 1/1000 cm^3 with a signal to noise ratio of 10:1. Further increase in the sensitivity can be obtained by summing the results of repeated measurements obtained at a given temperature. The system performance is evaluated by measuring the absorbed power in La_0.7 Sr_0.3 MnO_3 (LSMO) CMR manganite samples and superconducting Y Ba_2 Cu_3 O_7 (YBCO) samples at different rf frequencies. All operations during the measurements are automated using a computer with a menu-driven software system, user input being required only for the initiation of the measurement sequence.

Motivation & Objective

  • To develop a direct, sensitive method for measuring radiofrequency power absorption in weakly absorbing materials such as CMR oxides and high-Tc superconductors.
  • To overcome limitations of indirect or low-sensitivity techniques in studying microwave response of complex oxides at variable temperature and magnetic field.
  • To enable quantitative measurement of rf power absorption in samples as small as 1/1000 cm³ with high signal-to-noise ratio.
  • To integrate the measurement system with a commercial cryostat for precise temperature control from 4.2 K to 400 K.
  • To automate the measurement process using a menu-driven software interface for repeatability and ease of use.

Proposed method

  • The apparatus employs a self-resonant LC tank circuit driven by a 74LS04 NOT gate IC, operating in the 1–25 MHz frequency range.
  • The inductor (L) is a solenoid coil with the sample placed in its core, allowing direct measurement of rf power absorption via current change in the oscillator.
  • Power absorption is inferred from the change in supply current to the oscillator, which varies when the sample alters the Q-factor or resistance of the LC circuit.
  • A custom low-temperature insert enables integration with an Oxford Instruments cryostat and temperature controller for measurements from 4.2 K to 400 K.
  • An external electromagnet provides magnetic fields up to 1.4 T, allowing studies under combined thermal and magnetic field control.
  • The system uses a computer-controlled menu-driven software interface to automate measurement sequences, requiring only user initiation.

Experimental results

Research questions

  • RQ1Can a self-resonant LC oscillator circuit be effectively used to measure direct rf power absorption in CMR and high-Tc superconducting materials?
  • RQ2What is the minimum sample volume that can be reliably measured with sufficient signal-to-noise ratio using this method?
  • RQ3How does the rf power absorption vary with temperature and magnetic field in CMR manganites like La₀.₇Sr₀.₃MnO₃ and YBCO superconductors?
  • RQ4Can the system achieve sufficient sensitivity and stability for quantitative measurements in weakly absorbing materials at low temperatures?
  • RQ5To what extent can measurement sensitivity be enhanced through signal averaging of repeated measurements?

Key findings

  • The system achieves a signal-to-noise ratio of 10:1 for rf power absorption measurements in samples as small as 1/1000 cm³.
  • The method successfully measured rf power absorption in both La₀.₇Sr₀.₃MnO₃ (LSMO) and YBa₂Cu₃O₇ (YBCO) samples across the 1–25 MHz range.
  • The apparatus enables measurements over a temperature range from 4.2 K to 400 K and magnetic fields up to 1.4 T.
  • The sensitivity of the system can be further improved by summing repeated measurements, enhancing the effective signal-to-noise ratio.
  • The automated software interface allows for reliable, repeatable data acquisition with minimal user intervention during measurement sequences.
  • The system’s performance was validated through consistent and reproducible measurements on known CMR and superconducting materials, confirming its utility for low-power rf absorption studies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.