Skip to main content
QUICK REVIEW

[Paper Review] AC sensing using nitrogen vacancy centers in a diamond anvil cell up to 6 GPa

Zhipan Wang, Christopher McPherson|arXiv (Cornell University)|Oct 12, 2021
High-pressure geophysics and materialsEarth and Planetary Sciences63 references9 citations
TL;DR

This study demonstrates AC magnetic sensing using nitrogen-vacancy (NV) centers in diamond under high pressure in a diamond anvil cell (DAC), achieving synchronized readout up to 6 GPa. Despite reduced sensitivity due to microwave field and pressure inhomogeneities, the method enables all-optical, high-resolution magnetic resonance in nanoliter sample volumes, offering a pathway for nuclear magnetic resonance at extreme pressures.

ABSTRACT

Nitrogen-vacancy color centers in diamond have attracted broad attention as quantum sensors for both static and dynamic magnetic, electrical, strain and thermal fields, and are particularly attractive for quantum sensing under pressure in diamond anvil cells. Optically-based nuclear magnetic resonance may be possible at pressures greater than a few GPa, and offers an attractive alternative to conventional Faraday-induction based detection. Here we present AC sensing results and demonstrate synchronized readout up to 6 GPa, but find that the sensitivity is reduced due to inhomogeneities of the microwave field and pressure within the sample space. These experiments enable the possibility for all-optical high resolution magnetic resonance of nanoliter sample volumes at high pressures.

Motivation & Objective

  • To develop an all-optical method for high-resolution magnetic resonance in nanoliter sample volumes under extreme pressure.
  • To overcome limitations of conventional Faraday-induction-based NMR in diamond anvil cells due to small sample volumes and technical constraints.
  • To demonstrate AC sensing using NV centers for detecting dynamic magnetic fields at pressures up to 6 GPa.
  • To investigate the feasibility of optically detected magnetic resonance (ODMR) for nuclear spin precession detection under high pressure.
  • To identify and characterize sources of sensitivity degradation in high-pressure ODMR experiments.

Proposed method

  • Utilizes nitrogen-vacancy (NV) centers in synthetic diamond as quantum sensors for magnetic field detection.
  • Employs a long-working-distance objective (50X, NA 0.40) to excite and collect fluorescence from NV centers in the DAC.
  • Uses a straight gold antenna located across the diamond anvil culet to apply microwave fields for Rabi oscillations.
  • Applies an external magnetic field of ~29 mT at 54.7° from vertical to align with the NV axis along [111] for optimal ODMR.
  • Performs lateral scanning of the laser spot (20 µm step size) to map Rabi frequency and fluorescence intensity across the sample.
  • Synchronizes microwave excitation with optical readout to enable AC sensing of dynamic fields.

Experimental results

Research questions

  • RQ1Can AC sensing with NV centers be successfully implemented in a diamond anvil cell at pressures up to 6 GPa?
  • RQ2What are the dominant sources of sensitivity degradation in high-pressure ODMR experiments using NV centers?
  • RQ3How do microwave field inhomogeneities and pressure gradients affect the fidelity of AC sensing in a DAC?
  • RQ4To what extent can all-optical magnetic resonance detect dynamic fields in nanoliter sample volumes under extreme pressure?
  • RQ5Can synchronized microwave and optical readout enable high-resolution detection of nuclear spin precession in high-pressure environments?

Key findings

  • AC sensing with NV centers was successfully demonstrated up to 6 GPa in a diamond anvil cell, enabling all-optical detection of dynamic magnetic fields.
  • Sensitivity was reduced at high pressures due to inhomogeneities in both microwave field and pressure distribution across the sample space.
  • The Rabi frequency and fluorescence intensity were mapped across the sample, revealing spatial variations consistent with field and pressure inhomogeneities.
  • A 90° microwave pulse with a duration of ~50 ns was achieved at a microwave field amplitude of ~0.18 mT, corresponding to a Rabi frequency of ~5 MHz.
  • The experimental setup enabled synchronized optical readout and microwave excitation, validating the feasibility of AC sensing in high-pressure environments.
  • The results establish a foundation for future all-optical high-resolution NMR in nanoliter volumes at extreme pressures, particularly for studying hydrogen-rich materials.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.