Skip to main content
QUICK REVIEW

[Paper Review] ADENIUM - A demonstrator for a next-generation beam telescope at DESY

Yi Liu, Changqing Feng|arXiv (Cornell University)|Jan 1, 2023
Particle Detector Development and PerformancePhysics and Astronomy1 citations
TL;DR

ADENIUM is a next-generation beam telescope demonstrator based on ALPIDE sensors, designed as a drop-in replacement for legacy EUDET-style telescopes at DESY's test beam facility. It achieves sub-3 µm pointing resolution at 5.6 GeV electron momentum with no rate limitations up to 40 kHz, leveraging EUDAQ2 integration and modular DAQ for seamless compatibility with existing user detectors and infrastructure.

ABSTRACT

High-resolution beam telescopes for charged particle tracking are one of the most important and equally demanding infrastructure items at test beam facilities. The main purpose of beam telescopes is to provide precise reference track information of beam particles to measure the performance of a device under test (DUT). In this report the development of the ADENIUM beam telescope (ALPIDE sensor based DESY Next test beam Instrument) as a demonstrator and prototype for a next-generation beam telescope is presented. The ADENIUM beam telescope features up to six pixelated reference planes framed by plastic scintillators for triggering. ADENIUM is capable of replacing the currently used EUDET-type beam telescopes without impacting existing DUT implementations due to the integration of the telescope DAQ into EUDAQ2. In this report the concept and design of the ADENIUM telescope as well as its performance are discussed. The telescope's pointing resolution is determined in different configurations. For an optimal setup at an momentum of 5.6 GeV with an ALPIDE as DUT, a resolution better than 3 um has been extracted. No rate limitations have been observed at the DESY II test beam.

Motivation & Objective

  • To develop a high-resolution, next-generation beam telescope as a drop-in replacement for aging EUDET-style telescopes at DESY's test beam facility.
  • To ensure backward compatibility with existing user detector setups by integrating the telescope DAQ into the EUDAQ2 framework.
  • To demonstrate performance limits in spatial resolution, trigger rate, and noise efficiency under real test beam conditions at DESY II.
  • To validate the ALPIDE sensor as a superior alternative to the legacy Mimosa26 due to better availability, performance, and lower power consumption.
  • To lay the foundation for a long-term upgrade of all EUDET-style telescopes using a compact, scalable, and modular design.

Proposed method

  • The telescope uses six ALPIDE pixel sensors arranged in a modular configuration with plastic scintillators for beam triggering.
  • It employs a custom DAQ system integrated into the EUDAQ2 software framework to ensure compatibility with existing user detector setups.
  • Trigger signals from scintillators are processed via a logic unit and synchronized with the DAQ to enable precise time-stamping of hits.
  • Track reconstruction is performed using a built-in module that fits trajectories through hits on the reference planes, including interpolation to the DUT plane.
  • The system uses a geometric mean method to estimate the intrinsic DUT resolution from biased and unbiased residuals.
  • The telescope’s mechanical design allows flexible plane spacing and precise alignment to optimize tracking resolution.

Experimental results

Research questions

  • RQ1Can a new beam telescope achieve sub-3 µm pointing resolution while maintaining compatibility with existing EUDET-style infrastructure?
  • RQ2What is the maximum sustainable trigger rate of the ADENIUM system under DESY II test beam conditions?
  • RQ3How does the ALPIDE sensor compare to the legacy Mimosa26 in terms of spatial resolution, power efficiency, and long-term availability?
  • RQ4What is the impact of telescope plane spacing and particle momentum on tracking resolution?
  • RQ5Can the telescope achieve high performance without introducing rate limitations at beam rates up to 40 kHz?

Key findings

  • The ADENIUM telescope achieved a pointing resolution of 2.89 µm in the x-direction and 2.84 µm in the y-direction at 5.6 GeV electron momentum with optimal plane spacing.
  • No rate limitations were observed at trigger rates up to 40 kHz, the maximum available at the DESY II test beam.
  • The intrinsic spatial resolution of the DUT plane was estimated at 5.87 µm (x) and 5.74 µm (y) from unbiased residuals, confirming high-quality track reconstruction.
  • The telescope demonstrated full compatibility with existing EUDAQ2-based user detector systems, enabling seamless integration without additional configuration.
  • The ALPIDE sensor outperformed the legacy Mimosa26 in terms of active area, readout speed, and power efficiency, supporting its adoption as the new standard.
  • The system’s modular DAQ and compact design enable future upgrades, including integration of DAQ software on a Zynq SoC for enhanced real-time processing.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.