Skip to main content
QUICK REVIEW

[Paper Review] Application of Modified Multi Model Predictive Control Algorithm to Fluid Catalytic Cracking Unit

Nafay Hifzur Rehman, Neelam Verma|arXiv (Cornell University)|May 12, 2014
Fault Detection and Control SystemsEngineering5 citations
TL;DR

This paper proposes a modified multi-model predictive control (MPC) algorithm for fluid catalytic cracking units (FCCUs), using subspace system identification (N4SID) with PRBS excitation to build multiple linear models that capture varying operating conditions. The approach improves reference tracking and disturbance rejection in MIMO systems with hard constraints, outperforming single-model MPC in simulations using MATLAB/Simulink.

ABSTRACT

This paper presents a modified multi model predictive control algorithm for the control of riser outlet temperature and regenerator temperature for the fluid catalytic cracking unit (FCCU). The models of the fluid catalytic cracking unit are estimated using subspace identification (N4SID) algorithm. The PRBS signal is applied as an input signal to estimate the FCCU models. Since the estimated model does not give 100% fit; especially for nonlinear systems having more than one operating conditions, multi-model approach is proposed. In multi model, more than one model of FCCU used in MPC design. The main advantages of proposed method are that it can handle hard input and output constraints and it can be used for multi input multi output processes (MIMO) without increasing the complexity in control design. MATLAB/Simulink is used to estimate the models of FCCU and simulate the results for the controller. The simulation results show that the proposed algorithm provides better result for both reference tracking and disturbance rejection.

Motivation & Objective

  • To address the challenge of controlling nonlinear fluid catalytic cracking units (FCCUs) with multiple operating regimes.
  • To improve control performance for multi-input, multi-output (MIMO) systems with hard input and output constraints.
  • To develop a model predictive control strategy that maintains robustness and simplicity despite system nonlinearity.
  • To enhance reference tracking and disturbance rejection in FCCU temperature control using a multi-model framework.

Proposed method

  • Subspace system identification (N4SID) is used to estimate linear models of the FCCU from input-output data.
  • A pseudorandom binary sequence (PRBS) signal is applied as input to excite the system and collect data for model identification.
  • Multiple local linear models are constructed to represent different operating conditions of the FCCU.
  • A modified multi-model MPC algorithm combines these models using weighting schemes to improve control accuracy across operating regions.
  • The control design handles hard constraints on inputs and outputs without increasing algorithmic complexity.
  • MATLAB/Simulink is used to simulate the controller and validate performance on riser outlet and regenerator temperature control.

Experimental results

Research questions

  • RQ1Can a multi-model MPC approach improve control performance for a nonlinear FCCU with varying operating points?
  • RQ2How does the modified multi-model MPC compare to single-model MPC in terms of reference tracking and disturbance rejection?
  • RQ3Can the proposed method effectively manage hard constraints in a MIMO FCCU system without increasing design complexity?
  • RQ4To what extent does the use of PRBS-excited data enhance model accuracy in subspace identification for FCCU control?

Key findings

  • The proposed multi-model MPC significantly improves reference tracking performance compared to single-model MPC in simulations.
  • The controller demonstrates superior disturbance rejection capabilities under varying operating conditions.
  • The use of multiple models derived via N4SID with PRBS input results in more accurate system representation than a single global model.
  • The algorithm maintains robustness and simplicity in control design, even with hard input and output constraints.
  • Simulation results show reduced overshoot and faster settling times for both riser outlet and regenerator temperature control.
  • The method effectively handles the MIMO nature of the FCCU without increasing computational or design complexity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.