[Paper Review] Automated Breast Lesion Segmentation in Ultrasound Images
This paper proposes a three-stage automated method for breast lesion segmentation in ultrasound images using median filtering, normalized cuts for segmentation, and K-means clustering with contour selection for post-processing. The approach achieves a mean Dice coefficient of 0.8133 and Jaccard index of 0.6853, demonstrating robust performance on a diverse dataset despite challenges from speckle noise and low contrast.
The main objective of this project is to segment different breast ultrasound images to find out lesion area by discarding the low contrast regions as well as the inherent speckle noise. The proposed method consists of three stages (removing noise, segmentation, classification) in order to extract the correct lesion. We used normalized cuts approach to segment ultrasound images into regions of interest where we can possibly finds the lesion, and then K-means classifier is applied to decide finally the location of the lesion. For every original image, an annotated ground-truth image is given to perform comparison with the obtained experimental results, providing accurate evaluation measures.
Motivation & Objective
- To develop an automated method for segmenting breast lesions in ultrasound images to support early cancer detection.
- To address challenges posed by low-contrast regions and speckle noise inherent in ultrasound imaging.
- To improve segmentation accuracy by combining pre-processing, normalized cut segmentation, and K-means post-processing.
- To evaluate performance using standard metrics like Dice and Jaccard coefficients against ground-truth annotations.
- To reduce false positive and false negative rates in lesion detection for clinical decision support.
Proposed method
- Pre-processing involves median filtering and optional intensity enhancement via histogram equalization or contrast adjustment to reduce noise and improve image quality.
- Segmentation is performed using the normalized cut algorithm, which partitions the image into regions based on graph-based similarity, producing four candidate segmented images.
- Post-processing applies K-means clustering to each normalized cut result to separate foreground (lesion) and background clusters.
- The lesion is identified as the region with the minimal contour length among the K-means outputs, ensuring compactness and anatomical plausibility.
- In cases where K-means yields only one cluster, Otsu-thresholding is applied as a fallback to extract the lesion region.
- Evaluation is conducted using ground-truth annotations, with performance measured via Dice and Jaccard coefficients.
Experimental results
Research questions
- RQ1Can normalized cuts effectively segment breast lesions in low-contrast, speckle-noisy ultrasound images?
- RQ2How does the integration of K-means clustering and contour selection improve lesion localization accuracy?
- RQ3What is the impact of pre-processing steps (e.g., median filtering, histogram equalization) on segmentation performance?
- RQ4How do the proposed methods compare to traditional approaches like active contours or region growing in challenging ultrasound conditions?
- RQ5To what extent does the method generalize across varying lesion sizes and image quality?
Key findings
- The method achieved a mean Dice coefficient of 0.8133 and a mean Jaccard index of 0.6853 across 20 ultrasound images, indicating strong segmentation performance.
- Out of 20 images, 16 were successfully segmented, with the remaining 4 showing poor performance due to small lesion size or high noise.
- The highest Dice score was 0.9368 (image 000002), while the lowest was 0.0699 (image 000046), reflecting variability in lesion visibility.
- Images with successful segmentation showed low false positive and false negative rates, particularly in the first class (easy-to-segment cases).
- The computational time averaged 10.50 seconds per image, with a standard deviation of 1.89 seconds, indicating moderate processing efficiency.
- The method failed on three images (000019, 000014, 000030) where both Dice and Jaccard scores were zero, primarily due to lesions being merged with background or obscured by noise.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.