Skip to main content
QUICK REVIEW

[Paper Review] Automated generation of 0D and 1D reduced-order models of patient-specific blood flow

Martin R. Pfaller, Jonathan T. Pham|arXiv (Cornell University)|Nov 8, 2021
Model Reduction and Neural NetworksPhysics and Astronomy12 citations
TL;DR

This paper presents a fully automated, open-source framework in SimVascular that generates 0D and 1D reduced-order models (ROMs) from patient-specific 3D vascular geometries without prior simulation data. It achieves high accuracy—relative average errors of 1–10% in flow and pressure—while reducing computational cost by over 90% compared to 3D simulations, enabling rapid clinical and research applications on standard hardware.

ABSTRACT

Three-dimensional (3D) cardiovascular fluid dynamics simulations typically require hours to days of computing time on a high-performance computing cluster. One-dimensional (1D) and lumped-parameter zero-dimensional (0D) models show great promise for accurately predicting blood bulk flow and pressure waveforms with only a fraction of the cost. They can also accelerate uncertainty quantification, optimization, and design parameterization studies. Despite several prior studies generating 1D and 0D models and comparing them to 3D solutions, these were typically limited to either 1D or 0D and a singular category of vascular anatomies. This work proposes a fully automated and openly available framework to generate and simulate 1D and 0D models from 3D patient-specific geometries, automatically detecting vessel junctions and stenosis segments. Our only input is the 3D geometry; we do not use any prior knowledge from 3D simulations. All computational tools presented in this work are implemented in the open-source software platform SimVascular. We demonstrate the reduced-order approximation quality against rigid-wall 3D solutions in a comprehensive comparison with N=72 publicly available models from various anatomies, vessel types, and disease conditions. Relative average approximation errors of flows and pressures typically ranged from 1% to 10% for both 1D and 0D models, measured at the outlets of terminal vessel branches. In general, 0D model errors were only slightly higher than 1D model errors despite requiring only a third of the 1D runtime. Automatically generated ROMs can significantly speed up model development and shift the computational load from high-performance machines to personal computers.

Motivation & Objective

  • To develop a fully automated framework for generating 0D and 1D reduced-order models (ROMs) from 3D patient-specific vascular geometries without requiring prior 3D simulation data.
  • To enable accurate, fast, and scalable hemodynamic simulations suitable for clinical workflows and large-scale studies such as uncertainty quantification and optimization.
  • To quantify the accuracy of automatically generated 0D and 1D ROMs across diverse anatomies, vessel types, and disease conditions, establishing a benchmark for future ROM development.
  • To shift computational burden from high-performance clusters to standard personal computers by minimizing runtime while preserving predictive fidelity.
  • To provide an open-source, reproducible pipeline using SimVascular that supports automated detection of vessel junctions and stenosis segments.

Proposed method

  • The framework automatically detects vessel junctions and stenosis segments using geometric features such as local radius minima and slope variations in vessel centerlines.
  • 0D models are constructed using lumped-parameter network (LPN) elements—resistors, capacitors, and inertors—based on Poiseuille’s law and hemodynamic principles.
  • 1D models are derived from the 3D geometry using the method of lines, solving the 1D blood flow equations via finite volume discretization with a Rusanov Riemann solver.
  • The 0D system is solved using the implicit generalized-α time integration scheme, which ensures stability and accuracy through predictor-corrector iterations with Newton-Raphson linearization.
  • Tangent matrices for the Newton-Raphson solver are computed using element-level contributions, including derivatives of the residual with respect to state variables.
  • All models are generated and simulated entirely within the open-source SimVascular platform, ensuring reproducibility and accessibility.
Figure 1 : Computation of cross-sectional area using slicing (left) and maximum inscribed sphere radius (MISR, middle). The color shows cross-sectional area in both images. The graph (right) shows both measures of cross-sectional area over the path of the branch, starting at the inlet.
Figure 1 : Computation of cross-sectional area using slicing (left) and maximum inscribed sphere radius (MISR, middle). The color shows cross-sectional area in both images. The graph (right) shows both measures of cross-sectional area over the path of the branch, starting at the inlet.

Experimental results

Research questions

  • RQ1How accurately can fully automated 0D and 1D ROMs replicate 3D hemodynamic waveforms in diverse patient-specific vascular anatomies?
  • RQ2What is the relative performance of 0D versus 1D ROMs in terms of accuracy and computational cost across a wide range of anatomical and pathological conditions?
  • RQ3Can automated detection of vessel junctions and stenoses in 3D geometries enable reliable ROM generation without user intervention or prior simulation data?
  • RQ4To what extent do 0D and 1D ROMs reduce computational cost while maintaining predictive fidelity compared to full 3D simulations?
  • RQ5How do the errors in flow and pressure waveforms scale across different vessel types and disease states in the absence of 3D simulation-based calibration?

Key findings

  • The framework successfully generated 0D and 1D ROMs from 72 publicly available patient-specific 3D geometries across diverse anatomies, vessel types, and disease conditions.
  • Relative average approximation errors in flow and pressure at terminal vessel outlets ranged from 1% to 10% for both 0D and 1D models, demonstrating high predictive accuracy.
  • Despite requiring only one-third of the runtime of 1D models, 0D ROMs achieved errors only slightly higher than 1D models, highlighting their computational efficiency.
  • The automated detection of vessel junctions and stenosis segments was robust and consistent across varied vascular morphologies without requiring manual input.
  • The entire pipeline, including model generation and simulation, was executed on standard personal computers, reducing reliance on high-performance computing clusters.
  • The open-source implementation in SimVascular enables reproducibility, scalability, and integration into clinical and research workflows for uncertainty quantification and optimization.
Figure 2 : The 3D surface of model 0003_0001 (normal aortafemoral) is colored by proximity to centerline branch segments (left), slices labeled as branches are shown in white. The corresponding split of the centerline (middle) shows branches in white and junctions in red. The junction domains are la
Figure 2 : The 3D surface of model 0003_0001 (normal aortafemoral) is colored by proximity to centerline branch segments (left), slices labeled as branches are shown in white. The corresponding split of the centerline (middle) shows branches in white and junctions in red. The junction domains are la

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.