TL;DR

This paper presents a fully automated method for segmenting pulmonary arteries in low-dose CT scans using vessel tracking guided by airway proximity and model-based cylinder fitting. It achieves 90% specificity and 0.15 mm average segmentation error, with a novel sparse surface metric enabling efficient validation of complex vascular trees.

ABSTRACT

We present a fully automated method for top-down segmentation of the pulmonary arterial tree in low-dose thoracic CT images. The main basal pulmonary arteries are identified near the lung hilum by searching for candidate vessels adjacent to known airways, identified by our previously reported airway segmentation method. Model cylinders are iteratively fit to the vessels to track them into the lungs. Vessel bifurcations are detected by measuring the rate of change of vessel radii, and child vessels are segmented by initiating new trackers at bifurcation points. Validation is accomplished using our novel sparse surface (SS) evaluation metric. The SS metric was designed to quantify the magnitude of the segmentation error per vessel while significantly decreasing the manual marking burden for the human user. A total of 210 arteries and 205 veins were manually marked across seven test cases. 134/210 arteries were correctly segmented, with a specificity for arteries of 90%, and average segmentation error of 0.15 mm. This fully-automated segmentation is a promising method for improving lung nodule detection in low-dose CT screening scans, by separating vessels from surrounding iso-intensity objects.

Motivation & Objective

  • To develop a fully automated method for segmenting pulmonary arteries in low-dose CT scans, where contrast between vessels and surrounding tissues is minimal.
  • To address the challenge of separating isointense arterial and venous trees in low-contrast, noisy low-dose CT images.
  • To eliminate manual seed selection by automatically detecting initial seed points near airways using a previously developed airway segmentation algorithm.
  • To improve lung nodule detection and reduce false positives in pulmonary embolism screening by accurately isolating pulmonary arteries.
  • To introduce a novel, efficient validation metric—sparse surface (SS)—that reduces manual marking burden while maintaining accuracy in vascular tree evaluation.

Proposed method

  • Seed points for vessel tracking are automatically detected by searching near segmented airways, leveraging the anatomical proximity of airways and pulmonary arteries.
  • A model-based cylindrical vessel tracker iteratively fits cylinders to vessel paths, using geometric and intensity constraints to follow arteries into the lung parenchyma.
  • Bifurcations are detected by analyzing the rate of change of vessel radii, triggering new trackers at these points to segment daughter vessels.
  • The method uses a three-step preprocessing pipeline: median filtering to reduce noise, Hounsfield unit thresholding to isolate soft tissue, and airway wall removal via dilation and subtraction.
  • The algorithm maintains separation between arteries and veins by relying on predictable branching geometry and relative anatomical location, without requiring contrast enhancement.
  • A novel sparse surface (SS) metric is used for validation, requiring only a sparse set of manual markings to quantify segmentation accuracy and completeness per vessel.

Experimental results

Research questions

  • RQ1Can a fully automated method accurately segment pulmonary arteries in low-dose CT scans without manual seed selection?
  • RQ2How can arterial and venous trees be reliably separated when they have similar intensity and are isointense in non-contrast low-dose CT?
  • RQ3To what extent does a model-based vessel tracking approach with cylinder fitting improve segmentation accuracy in noisy, low-contrast environments?
  • RQ4Can a sparse surface marking scheme provide a reliable and efficient alternative to dense manual segmentation for validating complex vascular trees?
  • RQ5What are the primary failure modes of the algorithm, and how can they be mitigated in future iterations?

Key findings

  • The method successfully segmented 134 out of 210 pulmonary arteries in test cases, achieving a specificity of 90% for arterial structures.
  • The average segmentation error was 0.15 mm, indicating high geometric accuracy in vessel path reconstruction.
  • The sparse surface (SS) metric enabled efficient validation with a manageable number of manual markings, allowing evaluation across seven test cases.
  • The main source of error was false positive tracking into pulmonary veins, particularly in regions of high noise or abnormal anatomy.
  • The algorithm struggled to detect bifurcations in very small subsegmental arteries due to noise and deviations from Murray’s law in small vessels.
  • The method demonstrated robustness in segmenting large parent arteries and their early branches, but missed some small or abnormally sized vessels, especially at trifurcation points.