Skip to main content
QUICK REVIEW

[Paper Review] Bi-parametric prostate MR image synthesis using pathology and sequence-conditioned stable diffusion

Shaheer U. Saeed, Tom Syer|arXiv (Cornell University)|Mar 3, 2023
Generative Adversarial Networks and Image SynthesisComputer Science7 citations
TL;DR

This paper proposes a bi-parametric prostate MRI synthesis method using pathology- and sequence-conditioned stable diffusion to generate realistic multi-sequence MR images, conditioned on text or paired images. It achieves high realism, with radiologists only 59.4% accurate in distinguishing real from synthetic images, and shows strong potential for radiological training and data augmentation, improving ML model performance by 5.8% (p=0.004).

ABSTRACT

We propose an image synthesis mechanism for multi-sequence prostate MR images conditioned on text, to control lesion presence and sequence, as well as to generate paired bi-parametric images conditioned on images e.g. for generating diffusion-weighted MR from T2-weighted MR for paired data, which are two challenging tasks in pathological image synthesis. Our proposed mechanism utilises and builds upon the recent stable diffusion model by proposing image-based conditioning for paired data generation. We validate our method using 2D image slices from real suspected prostate cancer patients. The realism of the synthesised images is validated by means of a blind expert evaluation for identifying real versus fake images, where a radiologist with 4 years experience reading urological MR only achieves 59.4% accuracy across all tested sequences (where chance is 50%). For the first time, we evaluate the realism of the generated pathology by blind expert identification of the presence of suspected lesions, where we find that the clinician performs similarly for both real and synthesised images, with a 2.9 percentage point difference in lesion identification accuracy between real and synthesised images, demonstrating the potentials in radiological training purposes. Furthermore, we also show that a machine learning model, trained for lesion identification, shows better performance (76.2% vs 70.4%, statistically significant improvement) when trained with real data augmented by synthesised data as opposed to training with only real images, demonstrating usefulness for model training.

Motivation & Objective

  • To address the challenge of generating realistic, clinically relevant multi-sequence prostate MR images with controlled lesion presence and sequence type.
  • To overcome limitations of GAN-based methods, such as mode collapse and unstable training, in synthesizing subtle or under-represented prostate pathology.
  • To enable flexible data generation for training clinicians and machine learning models by conditioning on text (e.g., lesion presence) or paired images (e.g., T2W to DWI synthesis).
  • To validate the realism of generated images through blind expert evaluation and assess their utility in improving machine learning model performance.
  • To explore the feasibility of using diffusion models for medical image synthesis with complex, multi-modal clinical conditioning.

Proposed method

  • Adapts the stable diffusion model (SD) to enable image-based and text-based conditioning for prostate MRI synthesis.
  • Introduces a novel conditioning mechanism that allows control over both image sequence (e.g., T2W, ADC) and presence of suspected lesions (e.g., PIRADS ≥3).
  • Uses paired real data (e.g., T2W and DWI) to train the model to generate corresponding image pairs, enabling conditional synthesis from one modality to another.
  • Employs a text prompt to specify lesion status (e.g., 'with lesion' or 'without lesion') and sequence type, guiding the generation process.
  • Trains the model on 2D axial slices from real suspected prostate cancer patients, using a single NVIDIA Tesla V100 GPU over ~8 days.
  • Synthesis inference takes ~10 seconds per image on the same GPU, enabling practical deployment for training and augmentation tasks.

Experimental results

Research questions

  • RQ1Can a stable diffusion model generate realistic bi-parametric prostate MR images when conditioned on both text (e.g., lesion presence) and image sequences?
  • RQ2How realistic are the generated images when evaluated by expert radiologists in a blind setting?
  • RQ3Can the performance of radiologists in detecting lesions be preserved when using synthetic images instead of real ones?
  • RQ4To what extent can synthetic images improve the performance of machine learning models trained for prostate lesion detection?
  • RQ5What are the limitations of the current model in terms of anatomical region control and lesion localization?

Key findings

  • A radiologist achieved only 59.4% accuracy in distinguishing real from synthetic MRI images across all sequences, indicating high realism (chance level: 50%).
  • Lesion identification accuracy was 60.4% for real images and 62.6% for synthetic images, a difference of only 2.1 percentage points, demonstrating strong clinical realism.
  • A machine learning model trained on real data augmented with synthetic images achieved 76.2% accuracy in lesion detection, a statistically significant improvement over 70.4% when trained on real data alone (p=0.004).
  • The model showed consistent performance across sequences: 0.594 overall accuracy in real vs. synthetic image classification, with 0.688 AUC for ADC and 0.594 for T2W.
  • Synthetic image quality was superior to cGAN-based baselines, with fewer artifacts such as glandular disintegration or in-painting.
  • The model currently generates primarily central prostate regions due to lack of positional conditioning, suggesting a need for future work on anatomical localization control.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.