[Paper Review] Biometric-Based Wearable User Authentication During Sedentary and Non-sedentary Periods
This paper proposes an implicit wearable user authentication system using coarse-grained biometrics—step counts (behavioral), heart rate (physiological), and calorie burn/MET (hybrid)—collected at minute-level intervals. Evaluated on 421 Fitbit users over two years, it achieves 92% accuracy during sedentary periods and 88% during non-sedentary periods, with hybrid biometrics outperforming others.
The Internet of Things (IoT) is increasingly empowering people with an interconnected world of physical objects ranging from smart buildings to portable smart devices such as wearables. With the recent advances in mobile sensing, wearables have become a rich collection of portable sensors and are able to provide various types of services including health and fitness tracking, financial transactions, and unlocking smart locks and vehicles. Existing explicit authentication approaches (i.e., PINs or pattern locks) suffer from several limitations including limited display size, shoulder surfing, and recall burden. Oftentimes, users completely disable security features out of convenience. Therefore, there is a need for a burden-free (implicit) authentication mechanism for wearable device users based on easily obtainable biometric data. In this paper, we present an implicit wearable device user authentication mechanism using combinations of three types of coarse-grained minute-level biometrics: behavioral (step counts), physiological (heart rate), and hybrid (calorie burn and metabolic equivalent of task). From our analysis of 421 Fitbit users from a two-year long health study, we are able to authenticate subjects with average accuracy values of around 92% and 88% during sedentary and non-sedentary periods, respectively. Our findings also show that (a) behavioral biometrics do not work well during sedentary periods and (b) hybrid biometrics typically perform better than other biometrics.
Motivation & Objective
- Address the limitations of explicit authentication (e.g., PINs, pattern locks) on wearables, such as usability issues, shoulder surfing, and user avoidance due to burden.
- Overcome the shortcomings of existing biometric methods—especially poor performance during sedentary periods and high sensor/energy costs—by using coarse-grained, low-cost biometric data.
- Develop a generic, implicit authentication mechanism that remains effective across diverse user activity states using widely available wearable sensor data.
- Investigate the effectiveness of combining multiple biometric types (behavioral, physiological, hybrid) for robust user identification in real-world, long-term settings.
Proposed method
- Collect minute-level biometric data from 421 Fitbit users over a two-year health study, including step counts (behavioral), heart rate (physiological), and calorie burn/MET (hybrid).
- Use two feature selection approaches—COV (coefficient of variation) and KS (Kullback-Leibler divergence)—to identify the most discriminative biometric features for user authentication.
- Apply a classifier to authenticate users based on selected biometric features, with performance evaluated using accuracy (ACC) and false acceptance rate (FAR).
- Segment data into sedentary (l=0) and non-sedentary (l=1) periods to evaluate model performance under different activity states.
- Optimize parameter thresholds (e.g., xσt) for each feature selection method using graphical analysis to balance accuracy and false acceptance rate.
- Compare performance across biometric types and combinations, identifying the best-performing feature sets for each activity state and selection method.
Experimental results
Research questions
- RQ1Can coarse-grained, minute-level biometric data from wearables enable reliable implicit user authentication across both sedentary and non-sedentary periods?
- RQ2How do different biometric types—behavioral, physiological, and hybrid—perform in terms of authentication accuracy under varying activity states?
- RQ3What is the optimal combination of biometric features and feature selection techniques for maximizing authentication accuracy while minimizing computational and energy overhead?
- RQ4To what extent do hybrid biometrics (e.g., calorie burn and MET) outperform purely behavioral or physiological biometrics in real-world wearable settings?
- RQ5How does the performance of the authentication system vary between sedentary and non-sedentary periods, and can it maintain high accuracy when behavioral biometrics fail?
Key findings
- The proposed system achieves an average authentication accuracy of 92% during sedentary periods and 88% during non-sedentary periods using minute-level biometric data.
- Hybrid biometrics—specifically calorie burn (C) and metabolic equivalent of task (M)—consistently outperform other biometric types, achieving the highest accuracy across both activity states.
- Behavioral biometrics (step counts) perform poorly during sedentary periods, with accuracy dropping significantly when users are inactive.
- The KS feature selection approach yields higher average accuracy (76.26% in sedentary, 73.89% in non-sedentary) than COV, but at the cost of higher false acceptance rates (FAR) in sedentary conditions.
- The best-performing biometric combination during sedentary periods was C, M, and H (calorie burn, MET, and heart rate), achieving 55.46% accuracy under the COV approach.
- During non-sedentary periods, the combination of C and M (calorie burn and MET) achieved 88.00% accuracy using the COV approach with only 27 features, demonstrating high efficiency and robustness.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.