Skip to main content
QUICK REVIEW

[Paper Review] Calibration and improved prediction of computer models by universal Kriging

François Bachoc, Guillaume Bois|arXiv (Cornell University)|Jan 17, 2013
Probabilistic and Robust Engineering DesignDecision Sciences33 references34 citations
TL;DR

This paper proposes a universal Kriging framework to calibrate computer models and improve their predictions using experimental data by modeling the bias between the model and physical system as a Gaussian process. The method enables rigorous calibration, uncertainty quantification, and significant prediction improvements, demonstrated by reducing prediction errors by up to 30% in thermal-hydraulic code FLICA 4 applications.

ABSTRACT

This paper addresses the use of experimental data for calibrating a computer model and improving its predictions of the underlying physical system. A global statistical approach is proposed in which the bias between the computer model and the physical system is modeled as a realization of a Gaussian process. The application of classical statistical inference to this statistical model yields a rigorous method for calibrating the computer model and for adding to its predictions a statistical correction based on experimental data. This statistical correction can substantially improve the calibrated computer model for predicting the physical system on new experimental conditions. Furthermore, a quantification of the uncertainty of this prediction is provided. Physical expertise on the calibration parameters can also be taken into account in a Bayesian framework. Finally, the method is applied to the thermal-hydraulic code FLICA 4, in a single phase friction model framework. It allows to improve the predictions of the thermal-hydraulic code FLICA 4 significantly.

Motivation & Objective

  • Address the challenge of improving predictions of deterministic computer models by incorporating experimental data.
  • Quantify and reduce the bias between computer model outputs and real physical system behavior.
  • Provide a statistical framework for calibration that includes uncertainty quantification of predictions.
  • Integrate physical expertise on calibration parameters through a Bayesian approach.
  • Demonstrate the method's effectiveness in a real-world nuclear engineering application using the FLICA 4 code.

Proposed method

  • Model the discrepancy (bias) between the computer model and physical system as a realization of a zero-mean Gaussian process.
  • Use universal Kriging to jointly estimate the computer model parameters and the bias function, incorporating both experimental data and model structure.
  • Apply a Bayesian framework to incorporate prior knowledge on calibration parameters, updating beliefs via posterior distributions.
  • Estimate hyperparameters of the covariance function (e.g., Matérn, exponential) using maximum likelihood or cross-validation.
  • Use 10-fold cross-validation to assess prediction performance via RMSE and information criterion (IC).
  • Construct prediction intervals using the predictive mean and variance from the Kriging model to quantify uncertainty.

Experimental results

Research questions

  • RQ1How can experimental data be systematically used to calibrate a computer model and improve its predictive accuracy?
  • RQ2To what extent can a Gaussian process model of the bias reduce prediction errors in computer simulations?
  • RQ3How does incorporating prior physical knowledge on model parameters affect calibration performance and uncertainty quantification?
  • RQ4Which covariance function (e.g., Matérn, exponential) yields the most accurate and robust predictions in the presence of limited data?
  • RQ5Can the proposed method provide reliable prediction intervals that cover observed experimental outcomes?

Key findings

  • The universal Kriging approach significantly reduced prediction errors in the isothermal regime, with the Matérn 3/2 covariance function achieving an RMSE of 296.2 Pa.
  • In the single phase regime, the Matérn 3/2 and Matérn 5/2 covariance functions achieved the lowest RMSE of 196.2 Pa and 196.9 Pa, respectively.
  • The method provided well-calibrated prediction intervals, with 90% of prediction errors falling within the 90% confidence bounds in both regimes.
  • Incorporating prior information on calibration parameters improved posterior estimation and led to more accurate predictions, as shown in the posterior density contours.
  • The exponential covariance function yielded the best information criterion (IC) of 0.93 in the isothermal regime, indicating good model fit.
  • The application to the FLICA 4 thermal-hydraulic code demonstrated a substantial improvement in prediction accuracy, validating the method in a real nuclear engineering context.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.