[Paper Review] Calibration of the Charge and Energy Response of the MicroBooNE Liquid Argon Time Projection Chamber using Muons and Protons

C. Adams, J. Nowak|arXiv (Cornell University)|Mar 24, 2020
Muon and positron interactions and applicationsEngineering6 citations
TL;DR

This paper presents a data-driven calibration method for the MicroBooNE liquid argon time projection chamber that corrects for position- and time-dependent response variations in anode wire signals using cosmic-ray muons and beam-induced muons and protons. The method achieves a 3% absolute energy scale uncertainty and improves energy deposition and particle identification accuracy for highly ionizing particles.

ABSTRACT

We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including misconfigured or cross-connected TPC wires, space charge effects, electron attenuation, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 3\% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range.

Motivation & Objective

  • To address position- and time-dependent distortions in anode wire signals from ionization energy loss in the MicroBooNE liquid argon time projection chamber.
  • To correct for multiple detector effects including electron attenuation, diffusion, recombination, space charge, and wire misconfigurations.
  • To establish a precise absolute energy scale using fully-contained beam-induced muons stopping in the active volume.
  • To refine the charge-to-energy response for highly ionizing particles using stopping protons.
  • To improve total deposited energy measurement and particle identification based on dE/dx as a function of residual range.

Proposed method

  • Utilizes crossing cosmic-ray muons to identify and correct for time- and position-dependent signal distortions across the TPC anode wires.
  • Applies corrections for misconfigured or cross-connected wires, electron attenuation, diffusion, and recombination effects using the muon data.
  • Establishes the absolute energy scale by analyzing fully-contained muons that originate and stop within the active detector volume.
  • Uses stopping protons to calibrate the charge response for highly ionizing particles, improving the dE/dx response model.
  • Employs a data-driven approach to derive the charge-to-energy relationship without relying on simulation-only models.
  • Validates the calibration by comparing measured dE/dx values with expected energy loss for protons and muons across residual range.

Experimental results

Research questions

  • RQ1How can position- and time-dependent signal distortions in the MicroBooNE LArTPC be corrected using cosmic-ray muons?
  • RQ2What is the achievable uncertainty in the absolute energy scale when using beam-induced muons stopping in the active volume?
  • RQ3How does the charge response for highly ionizing particles, such as protons, compare to expected energy loss values?
  • RQ4To what extent does the calibration improve the accuracy of total deposited energy measurements?
  • RQ5Can the dE/dx response as a function of residual range be reliably calibrated using stopping protons?

Key findings

  • The calibration reduces position- and time-dependent signal distortions in the MicroBooNE LArTPC anode wire response.
  • The absolute energy scale is determined with a total uncertainty of 3% using beam-induced muons stopping in the active volume.
  • The charge-to-energy response for highly ionizing particles is refined using stopping protons, improving dE/dx measurements.
  • The data-driven calibration enhances the accuracy of total deposited energy reconstruction in the detector.
  • The method improves particle identification based on energy loss per unit length as a function of residual range.
  • The calibration enables more precise measurements of ionization energy loss, critical for neutrino interaction analysis.