[Paper Review] Characterisation of analogue Monolithic Active Pixel Sensor test structures implemented in a 65 nm CMOS imaging process
This paper characterizes analogue Monolithic Active Pixel Sensor (MAPS) test structures fabricated in a 65 nm CMOS imaging process, demonstrating high radiation tolerance and signal integrity under extreme irradiation. The modified-with-gap design achieved >99% detection efficiency up to 3 MGy TID and 1×10¹⁵ 1 MeV neq cm⁻² NIEL, with 4% energy resolution for Mn-Kα from ⁵⁵Fe, validating the technology for future high-energy physics detectors like ALICE ITS3 and the 3 Vertex Tracker.
Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterise and qualify this process and to optimise the sensor for the next generation of Monolithic Active Pixels Sensors for high-energy physics. The technology was explored in several variants which differed by: doping levels, pixel geometries and pixel pitches (10-25 $μ$m). These variants have been tested following exposure to varying levels of irradiation up to 3 MGy and $10^{16}$ 1 MeV n$_ ext{eq}$ cm$^{-2}$. Here the results from prototypes that feature direct analogue output of a 4$ imes$4 pixel matrix are reported, allowing the systematic and detailed study of charge collection properties. Measurements were taken both using $^{55}$Fe X-ray sources and in beam tests using minimum ionizing particles. The results not only demonstrate the feasibility of using this technology for particle detection but also serve as a reference for future applications and optimisations.
Motivation & Objective
- To characterize and qualify the 65 nm CMOS imaging process for use in Monolithic Active Pixel Sensors (MAPS) for high-energy physics (HEP).
- To evaluate the radiation tolerance of MAPS test structures under varying Total Ionizing Dose (TID) and Non-Ionizing Energy Loss (NIEL) levels.
- To optimize pixel design for improved charge collection efficiency, spatial resolution, and signal-to-noise ratio in high-rate, high-radiation environments.
- To provide a reference dataset for future MAPS development using this technology, especially for ALICE ITS3 and ALICE 3 Vertex Tracker.
Proposed method
- Fabricated 1.5 mm × 1.5 mm APTS chips with 4×4 active pixel matrices in 65 nm CMOS 65 nm ISC process, with pixel pitches of 10, 15, 20, and 25 µm.
- Implemented three pixel design variants: standard, modified, and modified with gap, to study charge sharing and collection efficiency.
- Conducted 55Fe X-ray source measurements to assess energy resolution and cluster size, and beam tests with minimum ionizing particles to evaluate spatial and detection efficiency.
- Applied reverse substrate bias to control depletion depth and studied its impact on charge collection and signal-to-noise ratio.
- Irradiated samples up to 3 MGy TID and 10¹⁶ 1 MeV neq cm⁻² NIEL to simulate long-term radiation exposure in HEP environments.
- Collected full analogue signal waveforms from individual pixels to enable detailed analysis of charge collection dynamics and cluster size evolution.
Experimental results
Research questions
- RQ1How does pixel pitch (10–25 µm) affect charge collection efficiency and spatial resolution in 65 nm CMOS MAPS under irradiation?
- RQ2What is the impact of different pixel design variants (standard, modified, modified with gap) on charge sharing, cluster size, and signal-to-noise ratio?
- RQ3To what extent does reverse substrate bias improve charge collection and detection efficiency in irradiated MAPS?
- RQ4What are the limits of radiation tolerance (TID and NIEL) for 65 nm CMOS MAPS in terms of detection efficiency and signal integrity?
- RQ5Can full analogue signal readout from 4×4 pixel matrices enable accurate reconstruction of charge cluster size and energy resolution under high radiation?
Key findings
- The modified-with-gap design achieved the highest charge collection efficiency and lowest charge sharing, resulting in a smaller average cluster size and improved signal-to-noise ratio across all pixel pitches.
- An energy resolution of 4% was achieved for the Mn-Kα peak from ⁵⁵Fe in the modified-with-gap design, indicating high energy resolution capability.
- Detection efficiency remained above 99% for all pixel pitches at reverse substrate bias and up to 3 MGy TID, meeting the requirements for ALICE ITS3.
- For NIEL, detection efficiency stayed above 99% up to 1×10¹⁵ 1 MeV neq cm⁻² for 15 µm pitch and 2×10¹⁵ 1 MeV neq cm⁻² for 10 µm pitch, exceeding ALICE ITS3 requirements.
- Averaged cluster size decreased with increasing NIEL and TID doses due to reduced charge collection efficiency, leading to a slight degradation in spatial resolution at high irradiation levels.
- The 25 µm pitch design showed the largest improvement in spatial resolution from full analogue readout due to larger cluster sizes, highlighting the benefit of analogue output in larger pixels.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.