Skip to main content
QUICK REVIEW

[Paper Review] Characterization of deformable mirrors for the MagAO-X project

Kyle Van Gorkom, Kelsey Miller|arXiv (Cornell University)|Jul 11, 2018
Adaptive optics and wavefront sensingPhysics and Astronomy4 references5 citations
TL;DR

This paper presents a high-precision characterization pipeline for deformable mirrors (DMs) used in the MagAO-X extreme adaptive optics system, employing Zygo interferometry and Karhunen-Loffe8s-based noise reduction to achieve sub-nanometer wavefront flatness. The method enables accurate command matrices for DMs, achieving 1.7nm RMS flatness over the MagAO-X coronagraphic pupil on an ALPAO DM97 and 3.5nm RMS over the beam footprint on a BMC Kilo-DM.

ABSTRACT

The MagAO-X instrument is an upgrade of the Magellan AO system that will introduce extreme adaptive optics capabilities for high-contrast imaging at visible and near-infrared wavelengths. A central component of this system is a 2040-actuator microelectromechanical (MEMS) deformable mirror (DM) from Boston Micromachines Corp. (BMC) that will operate at 3.63 kHz for high-order wavefront control. Two additional DMs from ALPAO will perform low-order and non-common-path science-arm wavefront correction. The accuracy of the wavefront correction is limited by our ability to command these DMs to a desired shape, which requires a careful characterization of each DM surface. We have developed a characterization pipeline that uses a Zygo Verifire Interferometer to measure the surface response and a Karhunen-Loève transform to remove noise from our measurements. We present our progress in the characterization process and the results of our pipeline applied to an ALPAO DM97 and a BMC Kilo-DM, demonstrating the ability to drive the DMs to a flat of $\lesssim$ 2nm and $\lesssim$ 4nm RMS in our beam footprint on the University of Arizona Wavefront Control (UAWFC) testbed.

Motivation & Objective

  • To enable high-contrast imaging in the MagAO-X extreme adaptive optics system by accurately characterizing deformable mirrors for precise wavefront control.
  • To overcome measurement noise and environmental disturbances in DM surface characterization using a robust signal processing pipeline.
  • To develop a repeatable, automated characterization workflow for both MEMS and electromagnetic DMs used in the MagAO-X instrument.
  • To achieve sub-nanometer wavefront flatness over the MagAO-X beam footprint and coronagraphic pupil for optimal starlight suppression.
  • To prepare for integration of the 2040-actuator BMC DM and dual ALPAO DM97s into the MagAO-X system with verified performance metrics.

Proposed method

  • Utilizes a Zygo Verifire Fizeau interferometer to measure the surface deformation of each DM actuator individually, capturing influence functions (IFs).
  • Applies a Karhunen-Loffe8s (KL) basis decomposition to subtract noise and environmental drift from measured IFs using a library of relaxed DM surface measurements.
  • Constructs a command matrix from cleaned IFs to enable accurate wavefront shaping via linear superposition of actuator responses.
  • Employs a Python-based automation pipeline synchronized across servers to control the DM and acquire interferometric data in a command-measure loop.
  • Uses the CACAO package for low-latency DM control and integrates with Zygo’s Python API for interferometer data acquisition and processing.
  • Applies the pseudo-inverse of the influence matrix (F†) to compute actuator commands (a) for a desired surface shape (s), following the equation: a = F†s.

Experimental results

Research questions

  • RQ1How can measurement noise and environmental drift be effectively removed from deformable mirror influence function measurements to improve wavefront control accuracy?
  • RQ2To what extent can a Karhunen-Loffe8s-based noise reduction technique enhance the fidelity of DM surface characterization?
  • RQ3What level of wavefront flatness can be achieved over the MagAO-X beam footprint and coronagraphic pupil using the developed characterization pipeline?
  • RQ4How do nonlinear actuator response and inter-actuator coupling affect wavefront control performance, and can they be modeled for predictive correction?
  • RQ5Can the characterization pipeline be reliably applied to both MEMS (BMC Kilo-DM) and electromagnetic (ALPAO DM97) deformable mirrors with consistent results?

Key findings

  • The characterization pipeline successfully reduced noise in influence function measurements using Karhunen-Loffe8s decomposition, enabling high-fidelity surface reconstruction.
  • An ALPAO DM97 achieved a wavefront flatness of 1.7nm RMS over the MagAO-X coronagraphic pupil, with 2.2nm RMS over the full 13.5mm aperture.
  • A BMC Kilo-DM (32x32) achieved 3.5nm RMS flatness over the UA Wavefront Control testbed beam footprint, demonstrating the pipeline’s effectiveness on similar DMs.
  • The BMC 2K DM (50x50, 2040 actuators) was reported to achieve 11.3nm RMS flatness over the coronagraphic pupil after defect masking, with 16.7nm RMS over the full 19.6mm aperture.
  • The pipeline enables accurate command matrices for wavefront control, with measured performance approaching the theoretical limits of DM surface accuracy.
  • The use of a high-reflectance Zygo reference flat is expected to eliminate pellicle-induced errors and further improve measurement precision in future characterization runs.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.