TL;DR

This paper evaluates monolithic CMOS sensors with small collection-electrode design using high-resistivity Czochralski (CZ) silicon substrates as an alternative to standard epitaxial layers. By replacing the 30 µm epitaxial layer with a 100 µm thick CZ substrate, the active sensor depth increases by a factor of two at -16 V bias, leading to a 15% improvement in spatial resolution, 14% in time resolution, and a doubled signal, significantly enhancing hit-detection efficiency and performance for particle tracking applications.

ABSTRACT

Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams are used to study the charge-collection properties and the performance of devices with different thicknesses both for perpendicular and inclined particle incidence. In CMOS sensors with a high-resistivity Czochralski substrate, the depth of the sensitive volume is found to increase by a factor two in comparison with standard epitaxial material and leads to significant improvements in the hit-detection efficiency and the spatial and time resolution.

Motivation & Objective

  • To investigate the impact of sensor thickness and substrate material on charge collection in monolithic small collection-electrode CMOS sensors.
  • To compare performance between standard epitaxial layers and high-resistivity Czochralski (CZ) silicon substrates in the CLICTD technology demonstrator.
  • To determine the effective active sensor depth using grazing angle and inclined particle beam techniques.
  • To evaluate improvements in spatial and time resolution, signal amplitude, and detection efficiency with thicker CZ substrates.

Proposed method

  • Fabricated CLICTD sensors with 40–300 µm thicknesses using backside grinding on epitaxial layers.
  • Produced and tested 100 µm thick sensors on high-resistivity Czochralski silicon substrates without epitaxial layers.
  • Performed beam tests at DESY's Test Beam Facility using charged particle beams at perpendicular and inclined incidence angles.
  • Measured charge-sharing properties and cluster sizes to infer active depth and spatial resolution.
  • Used the grazing angle technique to determine effective active sensor depth as a function of bias voltage.
  • Applied η-correction to extract true spatial resolution from cluster size data.

Experimental results

Research questions

  • RQ1How does sensor thickness affect charge collection and performance in small collection-electrode monolithic CMOS sensors?
  • RQ2What is the impact of replacing the epitaxial layer with a high-resistivity Czochralski silicon substrate on active sensor depth and signal amplitude?
  • RQ3How does inclined particle incidence affect charge sharing and spatial resolution in CLICTD sensors?
  • RQ4What is the maximum achievable active depth and signal gain using substrate biasing in CZ-based sensors?
  • RQ5To what extent do improvements in spatial and time resolution correlate with increased active depth?

Key findings

  • The active depth of CLICTD sensors with epitaxial layers is limited to approximately 30 µm, matching the nominal epitaxial thickness.
  • At a substrate bias of -16 V, the active depth in Czochralski-based sensors reaches 65.4 ± 0.1 (stat.)+0.5/-0.7 (syst.) µm, more than double that of epitaxial sensors.
  • The signal amplitude is expected to double in Czochralski sensors, reaching 4200–5200 e⁻, due to the increased active volume.
  • A 15% improvement in spatial resolution (3.6 ± 0.2 µm after η-correction) was observed at an inclination angle of 40°.
  • A 14% improvement in time resolution was measured, linked to the higher signal-to-noise ratio from increased charge collection.
  • The front-end electronics are not optimized for the larger signals from CZ substrates, limiting full performance potential.