[Paper Review] Comparison of U-net-based Convolutional Neural Networks for Liver Segmentation in CT
This study evaluates U-net-based convolutional neural networks for liver segmentation in CT scans using 219 annotated cases. It proposes an ensemble of 2D U-nets trained on orthogonal slices, which outperforms 3D U-nets due to hardware limitations, achieving mean and median Dice scores above 0.97 and superior surface distance metrics despite resampling-induced resolution loss.
Various approaches for liver segmentation in CT have been proposed: Besides statistical shape models, which played a major role in this research area, novel approaches on the basis of convolutional neural networks have been introduced recently. Using a set of 219 liver CT datasets with reference segmentations from liver surgery planning, we evaluate the performance of several neural network classifiers based on 2D and 3D U-net architectures. An interesting observation is that slice-wise approaches perform surprisingly well, with mean and median Dice coefficients above 0.97, and may be preferable over 3D approaches given current hardware and software limitations.
Motivation & Objective
- To compare the performance of 2D and 3D U-net architectures for liver segmentation in CT scans.
- To evaluate the impact of voxel resampling resolution (2 mm vs 1 mm) on segmentation accuracy.
- To investigate whether an ensemble of 2D U-nets trained on orthogonal views improves robustness over single 2D or 3D U-nets.
- To analyze the influence of loss functions (Dice vs binary cross-entropy) on model convergence and performance.
- To identify hardware and software constraints—particularly GPU memory—that limit 3D U-net training and inference.
Proposed method
- Trained multiple 2D and 3D U-net variants with four or five resolution levels on 219 CT volumes with expert-annotated liver segmentations.
- Applied isotropic resampling to 2 mm and 1 mm voxel sizes using Lanczos interpolation for CT data and nearest-neighbor for masks.
- Implemented an ensemble classifier combining three 2D U-nets trained on axial, sagittal, and coronal slices to improve spatial generalization.
- Used batch normalization before ReLU activations to accelerate training and improve convergence.
- Evaluated models using Dice coefficient, surface distance metrics (MICCAI score), and statistical significance tests (Wilcoxon signed-rank test).
- Compared training efficiency and memory usage across architectures, particularly focusing on batch size limitations due to 8 GiB GPU memory.
Experimental results
Research questions
- RQ1Does a 2D U-net ensemble trained on orthogonal views outperform single 2D and 3D U-net architectures in liver segmentation on CT scans?
- RQ2How do different voxel resampling resolutions (2 mm vs 1 mm) affect segmentation performance and surface distance metrics?
- RQ3To what extent do 3D U-net models underperform compared to 2D ensembles due to GPU memory constraints?
- RQ4Does the Dice loss provide a significant performance advantage over binary cross-entropy in this high-quality segmentation task?
- RQ5Can 2D slice-wise approaches achieve superior results to 3D models when hardware constraints limit 3D training batch sizes?
Key findings
- The ensemble of orthogonal 2D U-nets achieved a mean Dice coefficient above 0.97 and median Dice above 0.97, outperforming both single 2D and 3D U-net models.
- Despite resampling to 2 mm isotropic voxels, the 2D ensemble achieved MICCAI scores higher than untrained human experts, indicating high segmentation accuracy.
- The 3D U-net models performed significantly worse than the 2D ensemble, primarily due to limited GPU memory restricting effective batch sizes and training stability.
- The 3D U-net with padded convolutions (3Dpad U-net) significantly outperformed the naive 3D U-net, highlighting the importance of architectural modifications under memory constraints.
- The Dice loss did not significantly improve performance over binary cross-entropy in this dataset, likely due to the high quality of expert reference segmentations.
- Reducing voxel size from 2 mm to 1 mm improved MICCAI scores (p < 0.05) due to better surface distance metrics, but did not significantly improve volumetric overlap, indicating trade-offs between resolution and computational cost.