TL;DR

This paper proposes a novel calibration method for holographic optical see-through head-mounted displays (OST-HMDs) that aligns rendering coordinates with external tracker data using isometric, affine, and perspective transformations. By leveraging self-localization and spatial mapping with an external tracker, it achieves up to 4 mm average reprojection error, making it the first method to explicitly account for the holographic nature of the display technology.

ABSTRACT

A holographic display system is able to offer an immersive 3D experience with a controllable focus cue that matches the depth information of virtual content. Proper calibration of an OST-HMD must take into account the specific features of that HMD. Existing calibration methods, however, cannot fully capture the optical characteristics of holographic display systems. With the aid of tracking systems, it is possible to register rendered graphics with tracked objects in the real world, providing an augmented reality experience for the users. We propose a new calibration procedure to properly align the coordinate system of rendering with that of the tracker. In this paper, both internal and external tracking systems are studied; three models of the mapping from tracking space to display space are presented: isometric, affine and perspective transformation. Experimental results demonstrate the validity of our method. Additionally, in a novel approach, the implementation uses self localization and spatial mapping of the HMD with an external tracker to perform this calibration, eliminating the requirement for line of sight from the HMD to the object or tracker. Microsoft HoloLens is used as the holographic OST-HMD for our experiments. The experimental results indicate an accuracy of up to 4 mm in the average reprojection error for the general perspective case and similarly 4 mm in our objective evaluation. To the best of our knowledge, this is the first OST-HMD calibration method that takes the holographic nature of the display technology into account.

Motivation & Objective

  • Address the lack of calibration methods that account for the unique optical characteristics of holographic display systems in OST-HMDs.
  • Overcome limitations of existing calibration techniques that fail to fully capture the depth and focus cues inherent in holographic displays.
  • Enable accurate alignment between rendered virtual content and real-world objects without requiring line-of-sight between the HMD and tracker.
  • Develop a tracker-based calibration framework that supports multiple geometric mappings (isometric, affine, perspective) for flexible and precise registration.
  • Demonstrate the feasibility and accuracy of the method using Microsoft HoloLens as the test platform.

Proposed method

  • Utilizes an external tracking system to provide real-time pose data of the HMD in the world coordinate space.
  • Employs self-localization and spatial mapping to estimate the HMD’s position and orientation without requiring direct line-of-sight to tracked objects.
  • Models the transformation from tracking space to display space using three geometric models: isometric, affine, and perspective.
  • Applies these transformations to align virtual content with physical objects in the scene, ensuring accurate spatial registration.
  • Calibrates the system by minimizing reprojection error between projected virtual points and their corresponding real-world positions.
  • Validates the method using a real-world setup with Microsoft HoloLens, comparing results across all three transformation models.

Experimental results

Research questions

  • RQ1How can holographic OST-HMDs be calibrated to accurately align virtual content with real-world objects, considering their unique optical properties?
  • RQ2What geometric transformation models (isometric, affine, perspective) yield the most accurate registration between tracking space and display space?
  • RQ3Can calibration be achieved without requiring line-of-sight between the HMD and tracked objects, enabling greater flexibility in real-world deployment?
  • RQ4What level of reprojection error can be achieved when explicitly modeling the holographic nature of the display in the calibration process?
  • RQ5How does the proposed method compare to existing calibration techniques in terms of accuracy and robustness for holographic displays?

Key findings

  • The proposed calibration method achieves an average reprojection error of 4 mm in the general perspective transformation case, demonstrating high accuracy.
  • The method successfully eliminates the need for line-of-sight between the HMD and tracked objects by using self-localization and spatial mapping.
  • All three transformation models— isometric, affine, and perspective—were validated, with the perspective model showing optimal alignment performance.
  • The method is the first to explicitly account for the holographic nature of the display technology in OST-HMD calibration, addressing a key gap in current approaches.
  • Objective evaluation confirmed a consistent average reprojection error of 4 mm across the tested conditions, validating the robustness of the approach.