Skip to main content
QUICK REVIEW

[Paper Review] Compressed Sensing for Moving Imagery in Medical Imaging

Çağdaş Bilen, Yao Wang|arXiv (Cornell University)|Mar 26, 2012
Sparse and Compressive Sensing TechniquesEngineering1 references5 citations
TL;DR

This paper proposes a motion-compensating prior for compressed sensing reconstruction in dynamic medical imaging, leveraging optical flow constraints to sparsely represent moving images. By jointly or separately estimating motion and signal, the method significantly improves reconstruction quality—especially under high motion—outperforming traditional TV and DFT regularization in cardiac MRI datasets with up to 25% lower RMSE at high subsampling rates.

ABSTRACT

Numerous applications in signal processing have benefited from the theory of compressed sensing which shows that it is possible to reconstruct signals sampled below the Nyquist rate when certain conditions are satisfied. One of these conditions is that there exists a known transform that represents the signal with a sufficiently small number of non-zero coefficients. However when the signal to be reconstructed is composed of moving images or volumes, it is challenging to form such regularization constraints with traditional transforms such as wavelets. In this paper, we present a motion compensating prior for such signals that is derived directly from the optical flow constraint and can utilize the motion information during compressed sensing reconstruction. Proposed regularization method can be used in a wide variety of applications involving compressed sensing and images or volumes of moving and deforming objects. It is also shown that it is possible to estimate the signal and the motion jointly or separately. Practical examples from magnetic resonance imaging has been presented to demonstrate the benefit of the proposed method.

Motivation & Objective

  • To address the challenge of reconstructing moving images in compressed sensing when traditional sparsity-promoting transforms (e.g., wavelets, TV) fail due to motion.
  • To develop a motion-aware regularization method that exploits temporal correlation in dynamic imaging without requiring high-quality reference frames.
  • To enable joint or separate estimation of motion and signal during compressed sensing reconstruction for improved accuracy and robustness.
  • To demonstrate the method’s effectiveness in real-world medical imaging applications, particularly cardiac MRI with high motion.

Proposed method

  • Introduces a motion-compensating prior derived from the optical flow constraint, modeling temporal evolution of image intensity across frames.
  • Uses a sparsity-promoting regularization term based on motion-compensated differences, generalizing temporal TV to account for spatially varying motion.
  • Employs a split Bregman algorithm for optimization, allowing efficient solution of the non-convex, non-smooth minimization problem.
  • Supports both separate and joint optimization: separate for modularity and robustness, joint for improved convergence and performance under high motion.
  • Utilizes a sparse matrix representation of the motion-compensated transform (K_t(v)) to maintain computational efficiency.
  • Incorporates conjugate gradient methods for solving large-scale linear systems, minimizing computational overhead.

Experimental results

Research questions

  • RQ1Can a motion-compensating prior derived from optical flow improve compressed sensing reconstruction of moving medical images?
  • RQ2How does joint estimation of motion and signal compare to separate estimation in terms of reconstruction quality and computational cost?
  • RQ3Does the proposed method outperform standard regularization techniques (e.g., TV, DFT) in dynamic MRI with high motion?
  • RQ4Can the method be applied effectively when no high-quality reference frames are available?
  • RQ5How sensitive is the performance to motion estimation error, and can iterative refinement improve results?

Key findings

  • The proposed Motion-TV and Joint Motion-TV methods achieved lower RMSE than DFT and TV regularization across all tested subsampling rates (R=8 to R=14) in cardiac MRI datasets.
  • For Dataset 1, Motion-TV reduced RMSE by up to 25% compared to DFT at R=8 (0.0139 vs. 0.0220), with consistent improvement across all rates.
  • Joint Motion-TV outperformed separate Motion-TV in high-motion scenarios, showing robustness to poor initial reconstructions and reducing error by ~10% at R=14.
  • The joint estimation approach increased total execution time by ~20% due to motion registration, but maintained similar convergence speed (100 iterations sufficient).
  • The method demonstrated superior performance in high-motion cases where standard TV and DFT failed to adequately sparsify the signal.
  • The use of a sparse K_t(v) matrix ensured minimal computational overhead, with only a 10% increase in time per iteration compared to simpler transforms.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.