[Paper Review] COVID Detection in Chest CTs: Improving the Baseline on COV19-CT-DB
This paper proposes a dual approach for COVID-19 detection in chest CT scans—using 3D volumetric networks and slice-wise classification with aggregation—achieving a macro-F1 score of 0.92 on the COV19-CT-DB validation set, significantly improving the competition baseline of 0.70. The best results came from a slice-based method using neural architecture search (sharpDARTS), despite noisy slice-level labels from automated labeling procedures.
The paper presents a comparative analysis of three distinct approaches based on deep learning for COVID-19 detection in chest CTs. The first approach is a volumetric one, involving 3D convolutions, while the other two approaches perform at first slice-wise classification and then aggregate the results at the volume level. The experiments are carried on the COV19-CT-DB dataset, with the aim of addressing the challenge raised by the MIA-COV19D Competition within ICCV 2021. Our best results on the validation subset reach a macro-F1 score of 0.92, which improves considerably the baseline score of 0.70 set by the organizers.
Motivation & Objective
- To improve the baseline macro-F1 score of 0.70 set by the MIA-COV19D competition organizers on the COV19-CT-DB dataset.
- To evaluate and compare three deep learning approaches: a 3D volumetric method and two slice-wise methods with different aggregation strategies.
- To investigate the impact of noisy slice-level labeling on performance, using both naive and refined labeling procedures.
- To explore the effectiveness of neural architecture search (sharpDARTS) for learning optimal 2D convolutional architectures on slice-level classification.
- To provide a practical, interpretable method for identifying lung lesions in CT scans, supporting clinical localization of COVID-19 pathology.
Proposed method
- A 3D convolutional neural network processes entire CT volumes directly, using 3D convolutions to capture spatial context across axial slices.
- Two slice-wise approaches are employed: one using manually designed mini-volumes of three slices with logistic regression or MLP for aggregation, and another using sharpDARTS to search for optimal 2D CNN architectures.
- Slice-level labels are generated via a naive method (all slices in a COVID CT labeled as positive) and a refined method using a pre-trained tuberculosis detection model to identify potentially affected slices.
- The final CT-level prediction is made using a majority vote rule across slice-level predictions to determine the overall class.
- The sharpDARTS algorithm performs architecture search over 1 day, yielding a compact 61.3 MMAC model with 122.6 MFLOPS, trained for 300 epochs.
- Data augmentation and normalization are applied to individual slices, with intensity clipping to 350 HU window/level and normalization to [0,1] per volume.
Experimental results
Research questions
- RQ1Can a 3D volumetric deep learning model outperform slice-wise approaches in classifying COVID-19 from chest CTs on the COV19-CT-DB dataset?
- RQ2How does the performance of slice-wise classification methods vary when using different aggregation strategies (logistic regression, MLP, or neural architecture search) on the same labeled slices?
- RQ3To what extent does noisy slice-level labeling—introduced by automated labeling from non-COVID-annotated CTs—affect the final classification performance?
- RQ4Can neural architecture search (sharpDARTS) discover effective 2D CNN architectures for slice-level classification that generalize well to the full CT volume?
- RQ5Does the inclusion of lesion localization information through slice-wise classification improve clinical interpretability despite potential performance trade-offs?
Key findings
- The volumetric approach achieved the highest macro-F1 score of 0.96 on the training set and 0.92 on the validation set, significantly outperforming the baseline of 0.70.
- The slice-wise approach using sharpDARTS achieved a macro-F1 score of 0.74 on the validation set, despite being trained on noisy slice-level labels from an unrelated tuberculosis detection model.
- The slice-wise method based on mini-volumes and an MLP achieved a macro-F1 score of 0.97 on the training set and 0.84 on the validation set, indicating strong generalization with proper aggregation.
- The best-performing slice-wise method using sharpDARTS found a compact 61.3 MMAC architecture in just one day of search, demonstrating efficiency and effectiveness.
- The study confirms that slice-wise methods, while less accurate than 3D volumetric models, offer better interpretability by localizing potential lesions in the lungs.
- Despite the noise introduced by automated slice labeling, the best slice-wise method still achieved a macro-F1 score of 0.74 on validation, showing robustness to label imperfections.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.