[Paper Review] Data-driven Identification of Occupant Thermostat-Behavior Dynamics

Michael B. Kane, Kunind Sharma|arXiv (Cornell University)|Dec 13, 2019
Building Energy and Comfort OptimizationEngineering18 references10 citations
TL;DR

This paper proposes a data-driven model to identify occupant thermostat override behavior in response to setpoint changes, using 5-minute resolution data from 27,764 smart thermostats. It finds that larger setpoint changes trigger faster overrides—averaging ~30 minutes for a 2°F change and ~15 minutes for an 8°F change—highlighting discomfort magnitude as a key driver of behavioral response.

ABSTRACT

Building occupant behavior drives significant differences in building energy use, even in automated buildings. Users' distrust in the automation causes them to override settings. This results in responses that fail to satisfy both the occupants' and/or the building automation's objectives. The transition toward grid-interactive efficient buildings will make this evermore important as complex building control systems optimize not only for comfort, but also changing electricity costs. This paper presents a data-driven approach to study thermal comfort behavior dynamics which are not captured by standard steady-state comfort models such as predicted mean vote. The proposed model captures the time it takes for a user to override a thermostat setpoint change as a function of the manual setpoint change magnitude. The model was trained with the ecobee Donate Your Data dataset of 5 min. resolution data from 27,764 smart thermostats and occupancy sensors. The resulting population-level model shows that, on average, a 2°F override will occur after ~30 mins. and an 8°F override will occur in only ~15 mins., indicating the magnitude of discomfort as a key driver to the swiftness of an override. Such models could improve demand response programs through personalized controls.

Motivation & Objective

  • To understand how occupants dynamically respond to thermostat setpoint changes in real-world buildings.
  • To identify behavioral patterns that deviate from standard steady-state thermal comfort models like PMV.
  • To develop a population-level model of override timing based on empirical data from smart thermostats.
  • To support more effective demand response and personalized building control by modeling occupant behavior dynamics.
  • To quantify the relationship between setpoint change magnitude and the speed of occupant override actions.

Proposed method

  • Utilized the ecobee Donate Your Data dataset containing 5-minute resolution data from 27,764 smart thermostats and occupancy sensors.
  • Trained a data-driven model to predict the time-to-override as a function of the magnitude of manual setpoint changes.
  • Applied statistical modeling to extract temporal dynamics of occupant behavior from real-world override events.
  • Focused on population-level trends rather than individual-specific behavior to generalize findings.
  • Used time-series analysis to correlate setpoint changes with subsequent override actions, identifying response latency patterns.
  • Validated model performance using large-scale field data to ensure robustness and real-world relevance.

Experimental results

Research questions

  • RQ1How does the magnitude of a thermostat setpoint change influence the time until an occupant overrides the setting?
  • RQ2To what extent do occupants deviate from steady-state thermal comfort models in their actual behavior?
  • RQ3What are the dominant temporal patterns in occupant override behavior across a large population of buildings?
  • RQ4How can behavioral dynamics be modeled to improve building control strategies and demand response programs?
  • RQ5What role does perceived discomfort play in triggering rapid thermostat adjustments?

Key findings

  • On average, a 2°F thermostat setpoint change results in an override after approximately 30 minutes.
  • An 8°F setpoint change triggers an override in roughly 15 minutes, indicating a strong inverse relationship between discomfort magnitude and response time.
  • The data shows that occupants respond more quickly to larger deviations from their preferred temperature, suggesting discomfort is a primary motivator.
  • The model captures dynamic behavior not represented by traditional steady-state comfort models like PMV.
  • The population-level model reveals consistent override response patterns across diverse building and occupant types.
  • These findings demonstrate that behavioral dynamics significantly impact building energy use and must be modeled explicitly for effective automation and demand response.