[Paper Review] Decentralized Data-Enabled Predictive Control for Power System Oscillation Damping

Linbin Huang, Jeremy Coulson|arXiv (Cornell University)|Nov 27, 2019
Power System Optimization and StabilityEngineering47 references13 citations
TL;DR

This paper proposes a decentralized data-enabled predictive control (DeePC) framework for wide-area oscillation damping in power systems using only measured input/output data from VSC-HVDC stations, eliminating the need for detailed system models. The Min-Max DeePC algorithm enables robust, decentralized, and real-time control with improved damping performance even under noise, delays, and uncertainties, validated via high-fidelity simulations of a four-area system with a 0.44s solving time at k=16.

ABSTRACT

We employ a novel data-enabled predictive control (DeePC) algorithm in voltage source converter (VSC) based high-voltage DC (HVDC) stations to perform safe and optimal wide-area control for power system oscillation damping. Conventional optimal wide-area control is model-based. However, in practice detailed and accurate parametric power system models are rarely available. In contrast, the DeePC algorithm uses only input/output data measured from the unknown system to predict the future trajectories and calculate the optimal control policy. We showcase that the DeePC algorithm can effectively attenuate inter-area oscillations even in the presence of measurement noise, communication delays, nonlinear loads and uncertain load fluctuations. We investigate the performance under different matrix structures as data-driven predictors. Furthermore, we derive a novel Min-Max DeePC algorithm to be applied independently in multiple VSC-HVDC stations to mitigate inter-area oscillations, which enables decentralized and robust optimal wide-area control. Further, we discuss how to relieve the computational burden of the Min-Max DeePC by reducing the dimension of prediction uncertainty and how to leverage disturbance feedback to reduce the conservativeness of robustification. We illustrate our results with high-fidelity, nonlinear, and noisy simulations of a four-area test system.

Motivation & Objective

  • To address the limitations of model-based wide-area control in power systems, where accurate system models are often unavailable due to parameter uncertainty, unknown device control laws, and dynamic grid changes.
  • To develop a data-driven control approach that leverages only input/output measurements from VSC-HVDC stations to predict system behavior and compute optimal control actions without relying on parametric system models.
  • To enable decentralized, robust, and real-time wide-area damping control by introducing a Min-Max DeePC algorithm that accounts for uncertainty in future disturbances.
  • To reduce computational burden and conservativeness in robust control by introducing disturbance feedback and dimensionality reduction techniques in the prediction horizon.

Proposed method

  • The DeePC algorithm uses a data Hankel matrix constructed from measured input/output trajectories to represent the system's behavior in a data-centric, non-parametric manner, enabling future trajectory prediction without system identification.
  • The Min-Max DeePC formulation incorporates worst-case disturbance uncertainty in the optimization, ensuring robustness against future disturbances while enabling decentralized implementation across multiple VSC-HVDC stations.
  • Noise filtering is applied via singular value decomposition (SVD) on the data Hankel matrix to improve prediction accuracy under noisy measurements.
  • A disturbance feedback (DF) policy is introduced to reduce conservativeness by incorporating feedback effects into the robust optimization, allowing longer prediction horizons without performance degradation.
  • The robust optimization problem is solved using the YALMIP toolbox with a control horizon of k=16, achieving a solving time of approximately 0.44s on standard hardware, enabling real-time implementation.
  • The framework is validated using a high-fidelity, nonlinear, and noisy four-area power system test case with VSC-HVDC stations and nonlinear loads.
Figure 1: One-line diagram of a four-area test system with integration of an HVDC link.
Figure 1: One-line diagram of a four-area test system with integration of an HVDC link.

Experimental results

Research questions

  • RQ1Can a data-driven control approach effectively damp inter-area oscillations in power systems without requiring a parametric system model?
  • RQ2How does the performance of Min-Max DeePC compare to standard DeePC under communication delays, measurement noise, and load fluctuations?
  • RQ3To what extent can disturbance feedback reduce the conservativeness of robust control in the presence of uncertain future disturbances?
  • RQ4What is the computational feasibility of implementing Min-Max DeePC in real time, and how does dimensionality reduction affect its scalability?
  • RQ5Can decentralized implementation of DeePC maintain system-wide damping performance without a centralized controller?

Key findings

  • The Min-Max DeePC algorithm achieves significantly higher damping ratios than standard DeePC under long control horizons (k=16), with DF Min-Max DeePC maintaining high performance even at k=24, while standard Min-Max DeePC fails to eliminate oscillations.
  • The disturbance feedback policy reduces conservativeness, enabling longer prediction horizons and improved robustness, as demonstrated by sustained high damping ratios beyond k=22.
  • The solving time for the robust optimization problem is approximately 0.44 seconds on an Intel Core i5 7200U CPU with 8GB RAM, confirming real-time feasibility for k≥22.
  • Noise filtering via SVD on the data Hankel matrix significantly improves prediction accuracy and damping performance under noisy measurements.
  • The decentralized Min-Max DeePC framework effectively mitigates inter-area oscillations across all four areas, demonstrating scalability and reliability without centralized coordination.
  • The framework maintains robust performance under nonlinear loads, load fluctuations, and communication delays, confirming its practical viability for real-world power systems.
Figure 2: Centralized wide-area control based on DeePC.
Figure 2: Centralized wide-area control based on DeePC.