[Paper Review] Deep Learning for Pneumothorax Detection and Localization in Chest Radiographs

André Gooßen, Hrishikesh Deshpande|arXiv (Cornell University)|Jul 16, 2019
COVID-19 diagnosis using AIMedicine12 references18 citations
TL;DR

This paper proposes and evaluates three deep learning approaches—convolutional neural networks (CNN), multiple-instance learning (MIL), and fully convolutional networks (FCN)—for detecting and localizing pneumothorax in chest X-rays. The CNN achieved the highest AUC of 0.96, while the ensemble of all three methods reached 0.965, demonstrating strong performance for clinical triage applications.

ABSTRACT

Pneumothorax is a critical condition that requires timely communication and immediate action. In order to prevent significant morbidity or patient death, early detection is crucial. For the task of pneumothorax detection, we study the characteristics of three different deep learning techniques: (i) convolutional neural networks, (ii) multiple-instance learning, and (iii) fully convolutional networks. We perform a five-fold cross-validation on a dataset consisting of 1003 chest X-ray images. ROC analysis yields AUCs of 0.96, 0.93, and 0.92 for the three methods, respectively. We review the classification and localization performance of these approaches as well as an ensemble of the three aforementioned techniques.

Motivation & Objective

  • To develop automated deep learning systems for timely detection of pneumothorax in chest X-rays, a critical condition requiring immediate intervention.
  • To compare the performance of three deep learning architectures—CNN, MIL, and FCN—in both classification and localization of pneumothorax.
  • To evaluate whether ensemble learning can improve detection accuracy beyond individual models.
  • To assess the clinical utility of these models in prioritizing critical findings, especially for Category 1 findings as defined by the ACR.
  • To investigate the interpretability and localization confidence of each method, particularly through pixel-level segmentation in FCN.

Proposed method

  • A ResNet-50 variant with 448×448 input resolution and single-channel input was fine-tuned on the NIH ChestX-ray14 dataset for binary pneumothorax classification.
  • Multiple-Instance Learning (MIL) partitions each X-ray into overlapping patches, uses a pre-trained CNN as a patch classifier, and applies max-pooling over patch scores to predict image-level labels.
  • A U-Net-based Fully Convolutional Network (FCN) performs end-to-end pixel-wise classification, using dice loss and learning rate scheduling for segmentation of pneumothorax regions.
  • An ensemble model combines predictions from CNN, MIL, and FCN using linear weighting, optimized via exhaustive search to maximize AUC.
  • Five-fold cross-validation was applied on a dataset of 1,003 chest X-ray images to ensure robust performance evaluation.
  • All models were trained and evaluated using standard metrics: AUC, Dice coefficient, and TPR/FPR at specific operating points.

Experimental results

Research questions

  • RQ1Can a fine-tuned ResNet-50 achieve high AUC for pneumothorax detection in chest X-rays using transfer learning?
  • RQ2To what extent does MIL enable joint classification and localization without requiring pixel-level annotations?
  • RQ3How does the FCN’s pixel-level segmentation performance compare to image-level methods in terms of localization accuracy and Dice score?
  • RQ4Does ensembling the three models significantly improve overall detection performance compared to individual models?
  • RQ5Which model offers the best balance between high AUC and low false positive rate for clinical worklist prioritization?

Key findings

  • The CNN achieved the highest AUC of 0.96, outperforming MIL (AUC 0.93) and FCN (AUC 0.92) on the 1,003-image dataset.
  • The ensemble of CNN, MIL, and FCN achieved the highest AUC of 0.965, though not significantly better than the CNN alone.
  • The FCN achieved a mean Dice coefficient of 54.2% on positively classified cases, indicating moderate localization accuracy.
  • At 1% false positive rate, the FCN detected 57% of pneumothorax cases, while the ensemble detected 68%.
  • The CNN and FCN combination achieved an AUC of 0.962, the best two-model ensemble performance.
  • The models demonstrated stable performance across five-fold cross-validation, with AUC values between 0.92 and 0.96.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.