Skip to main content
QUICK REVIEW

[Paper Review] DiffusionPoser: Real-time Human Motion Reconstruction From Arbitrary Sparse Sensors Using Autoregressive Diffusion

Tom Van Wouwe, Seung‐Hwan Lee|arXiv (Cornell University)|Aug 31, 2023
Balance, Gait, and Falls PreventionHealth Professions5 citations
TL;DR

This paper proposes Diffusion Inertial Poser (DiffIP), a real-time, single diffusion generative model that reconstructs full-body human motion from arbitrary sparse IMU configurations without retraining. By leveraging autoregressive denoising and a physiologically realistic OpenSim-based motion representation, DiffIP achieves state-of-the-art accuracy for six-IMU setups and maintains human-like motion quality even with as few as three IMUs, enabling flexible, application-specific sensor deployment in health and performance monitoring.

ABSTRACT

Motion capture from a limited number of body-worn sensors, such as inertial measurement units (IMUs) and pressure insoles, has important applications in health, human performance, and entertainment. Recent work has focused on accurately reconstructing whole-body motion from a specific sensor configuration using six IMUs. While a common goal across applications is to use the minimal number of sensors to achieve required accuracy, the optimal arrangement of the sensors might differ from application to application. We propose a single diffusion model, DiffusionPoser, which reconstructs human motion in real-time from an arbitrary combination of sensors, including IMUs placed at specified locations, and, pressure insoles. Unlike existing methods, our model grants users the flexibility to determine the number and arrangement of sensors tailored to the specific activity of interest, without the need for retraining. A novel autoregressive inferencing scheme ensures real-time motion reconstruction that closely aligns with measured sensor signals. The generative nature of DiffusionPoser ensures realistic behavior, even for degrees-of-freedom not directly measured. Qualitative results can be found on our website: https://diffusionposer.github.io/.

Motivation & Objective

  • To develop a flexible, real-time motion reconstruction system for human movement using arbitrary sparse IMU configurations without requiring model retraining.
  • To improve robustness and accuracy in reconstructing uninstrumented body parts when sensor data is sparse or noisy.
  • To enable practical deployment in health, rehabilitation, and performance monitoring by supporting diverse IMU configurations tailored to specific application needs.
  • To integrate physiologically realistic musculoskeletal models (OpenSim) for biomechanically meaningful outputs such as muscle forces and joint kinematics.
  • To create and release a large-scale, OpenSim-compatible dataset synthesized from marker-based motion capture for training and evaluation.

Proposed method

  • A conditional autoregressive diffusion model is trained to generate full-body motion sequences from global segment orientations and linear accelerations measured by IMUs.
  • The model uses a noise schedule and denoising U-Net architecture to iteratively refine motion predictions, conditioned on past frames and IMU measurements.
  • IMU configurations are encoded via a learnable mask that identifies which body segments are instrumented, allowing the model to generalize across arbitrary setups.
  • The training data is synthesized from three existing marker-based motion capture datasets using AddBiomechanics, mapped to OpenSim-compatible kinematic representations.
  • Motion is reconstructed in real-time at 20Hz by autoregressively sampling denoising steps, with inference latency under 110ms.
  • The model is trained to minimize joint angle error (MJOE), position error (MJPE), and root translation error (RTE) across diverse configurations.

Experimental results

Research questions

  • RQ1Can a single diffusion model generalize across arbitrary IMU configurations without retraining, maintaining high reconstruction accuracy?
  • RQ2How does the performance of the diffusion model compare to regression-based baselines in terms of robustness and accuracy under sensor sparsity?
  • RQ3Which IMU configurations minimize joint angle and global translation errors for different motion types and sensor counts?
  • RQ4To what extent can a generative model produce plausible motion for uninstrumented limbs when sensor data is sparse?
  • RQ5Can the model be effectively deployed in real-time for applications requiring low-latency feedback, such as biofeedback or VR?

Key findings

  • DiffIP achieves state-of-the-art performance on the standard six-IMU configuration, with a mean joint orientation error (MJOE) of 14.7° and mean joint position error (MJPE) of 7.5 cm.
  • For four-IMU configurations, instrumenting the thighs and forearms yields the lowest joint error (MJOE: 14.7°), while using feet instead of thighs reduces root drift (RTE10s: 0.34m vs. 0.36m).
  • With only three IMUs, DiffIP maintains human-like motion quality, though joint error increases to 22.8° MJOE and RTE10s reaches 1.0m, demonstrating generative robustness.
  • Compared to a conditional transformer baseline (c-trans), DiffIP shows superior robustness and lower error across all configurations, with a 25% lower MJOE on average.
  • The system runs at 20Hz with a total latency of ~110ms, including sensor communication, filtering, and inference, enabling real-time use in feedback-driven applications.
  • The model generalizes across configurations without retraining, allowing users to select optimal IMU setups based on practical constraints and application goals.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.