Skip to main content
QUICK REVIEW

[Paper Review] Dissociative electron attachment dynamics of carbon disulfide and violation of axial recoil approximation near the 6-eV resonance

Anirban Paul, Dhananjay Nandi|arXiv (Cornell University)|May 20, 2022
Atomic and Molecular PhysicsPhysics and Astronomy33 references4 citations
TL;DR

This study investigates the dissociative electron attachment (DEA) dynamics in carbon disulfide (CS2) near the 6.2 eV resonance using velocity slice imaging (VSI), revealing significant deviations from the axial recoil approximation due to bending of the temporary negative ion (TNI). The angular distributions of S− and CS− fragment ions show that TNI bending leads to broadened and asymmetric emission patterns, with FWHM values of 56° and 74° for high- and low-energy ions, respectively, indicating strong non-linear dissociation dynamics.

ABSTRACT

Complete dissociation dynamics of low-energy electron attachment to carbon disulfide have been studied using the velocity slice imaging (VSI) technique. The ion yields of S- and CS- fragment ions as the function of incident electron energy in the range 5 to 11 eV have been obtained. Two resonances for S- ions at around 6.2 eV and 7.7 eV and only one resonance for CS- ions at around 6.2 eV have been obtained in this energy range. The kinetic energy and the angular distributions of these fragment negative ions at different incident electron energies around these resonances have been measured. From the angular distribution of these fragment anions, we have found that the bending of the temporary negative ions causes a significant change in the angular distribution from the expected one.

Motivation & Objective

  • To understand the dissociation dynamics of low-energy electron attachment to CS2, particularly near the 6.2 eV resonance.
  • To measure kinetic energy and angular distributions of S− and CS− fragment anions using velocity slice imaging (VSI).
  • To investigate the validity of the axial recoil approximation in DEA processes for linear triatomic molecules.
  • To determine the role of TNI bending in distorting angular emission patterns of fragment anions.

Proposed method

  • Velocity slice imaging (VSI) was employed to measure the momentum distributions of S− and CS− fragment ions from electron attachment to CS2.
  • A pulsed electron beam (200 ns) crossed perpendicularly with an ejection molecular beam in a VSI spectrometer to produce transient negative ions (TNIs).
  • A 4 µs negative extraction pulse at the pusher plate focused ions onto a 2D position-sensitive detector (PSD) via a lens electrode and conical drift tube.
  • Angular distributions were extracted from momentum images and fitted using a convolution model: IBending(θ) = ∫ e−ψ²/2σ² IAxialRecoil(θ−ψ) dψ, where ψ is the bending angle.
  • The axial recoil distribution IAxialRecoil(θ) was modeled as |a1Y11 + a3Y13 eiδ|², incorporating spherical harmonics and phase differences.
  • Fitting parameters, including FWHM of the Gaussian distribution (σ), were extracted to quantify the extent of TNI bending.

Experimental results

Research questions

  • RQ1To what extent does TNI bending violate the axial recoil approximation in DEA of CS2 at 6.2 eV?
  • RQ2How do the kinetic energy and angular distributions of S− and CS− fragments differ across the 6.2 eV resonance?
  • RQ3What is the role of vibrational excitation in the formation of low-energy S− and CS− ions?
  • RQ4Why is the angular distribution of fragment anions broader for low-energy ions compared to high-energy ions?
  • RQ5What symmetry and dynamics underlie the 7.7 eV resonance, given the lack of prior theoretical models?

Key findings

  • The S− ion yield exhibits two resonances at 6.2 eV and 7.7 eV, while the CS− ion yield shows only one resonance at 6.2 eV.
  • The kinetic energy distribution of S− ions shows two distinct peaks: one near 0 eV and another that decreases beyond 7.2 eV, suggesting dissociation via three-body or second two-body channels at 7.7 eV.
  • Low-energy S− ions are attributed to CS fragments in highly vibrational excited states, as their peak position remains constant with incident energy.
  • The angular distribution of fragment anions cannot be explained by axial recoil; instead, TNI bending significantly distorts the emission pattern.
  • The FWHM of the Gaussian convolution function for TNI bending is 56° for high-energy S− ions and 74° for low-energy S− ions, indicating greater contribution from bent TNI geometries at lower energies.
  • The angular distribution of CS− ions is similar to that of S− ions, with FWHM values of 48° (high energy) and 74° (low energy), confirming consistent bending effects across fragment types.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint