[Paper Review] Domain Adaptation for MRI Organ Segmentation using Reverse Classification Accuracy
This paper proposes a novel domain adaptation framework, DARCA, that uses Reverse Classification Accuracy (RCA) to automatically select the most informative subjects from a target MRI domain for annotation, significantly reducing labeling effort. By selecting a combination of the highest- and lowest-confidence predictions from RCA, the method achieves segmentation performance comparable to full fine-tuning with all target data, demonstrating that RCA-guided subject selection can effectively reduce annotation burden while maintaining high accuracy in multi-center MRI organ segmentation.
The variations in multi-center data in medical imaging studies have brought the necessity of domain adaptation. Despite the advancement of machine learning in automatic segmentation, performance often degrades when algorithms are applied on new data acquired from different scanners or sequences than the training data. Manual annotation is costly and time consuming if it has to be carried out for every new target domain. In this work, we investigate automatic selection of suitable subjects to be annotated for supervised domain adaptation using the concept of reverse classification accuracy (RCA). RCA predicts the performance of a trained model on data from the new domain and different strategies of selecting subjects to be included in the adaptation via transfer learning are evaluated. We perform experiments on a two-center MR database for the task of organ segmentation. We show that subject selection via RCA can reduce the burden of annotation of new data for the target domain.
Motivation & Objective
- To address the challenge of performance degradation in MRI organ segmentation when deploying models trained on one scanner or protocol to a new domain with different imaging characteristics.
- To reduce the high cost and time of manual annotation for new target domains by identifying the most 'valuable' subjects for labeling using a data-driven criterion.
- To evaluate whether Reverse Classification Accuracy (RCA) can serve as an effective proxy for selecting subjects that maximize domain adaptation performance.
- To compare different subject selection strategies—based on RCA—against baseline methods like full fine-tuning and random selection in supervised domain adaptation.
- To investigate the impact of training set size and sample composition (e.g., combining high- and low-confidence predictions) on segmentation performance.
Proposed method
- The method employs Reverse Classification Accuracy (RCA), a metric that predicts the Dice Similarity Coefficient (DSC) of a model on unlabeled target data without requiring ground truth, to rank the informativeness of target domain subjects.
- A baseline model is first trained on the source domain (MALIBO dataset) and then used to predict RCA scores for all unlabeled target domain subjects (UK Biobank data).
- Subjects are selected based on their RCA scores: the top 5 (highest confidence) and bottom 5 (lowest confidence) predictions are chosen for annotation and inclusion in the fine-tuning process.
- The selected subjects are used to fine-tune the source model via transfer learning, with performance evaluated using DSC on the full target test set.
- Multiple strategies are compared: fine-tuning with all target data, random selection, only best/worst 5, and the combined best- and worst-5 selection, both with real DSCs and RCA-predicted DSCs.
- The approach is validated on two tasks: liver segmentation and right kidney segmentation, using 35 source subjects and 45 target subjects from different scanners and protocols.
Experimental results
Research questions
- RQ1Can Reverse Classification Accuracy (RCA) effectively predict which target domain subjects will yield the highest performance gains when annotated and used for fine-tuning?
- RQ2Does combining high- and low-confidence RCA predictions lead to better domain adaptation performance than selecting only the best or worst subjects?
- RQ3How does the performance of DARCA compare to full fine-tuning with all target data, especially in terms of DSC and annotation efficiency?
- RQ4Can RCA-guided subject selection achieve performance comparable to training from scratch with all target data, while drastically reducing annotation cost?
- RQ5How robust is the RCA-based selection across different organ segmentation tasks and varying levels of domain shift?
Key findings
- The combination of the best-5 and worst-5 subjects selected via RCA achieved a DSC of 0.726 for liver segmentation, outperforming fine-tuning with all 45 target subjects (DSC: 0.658).
- For right kidney segmentation, the RCA-selected best- and worst-5 combination achieved a DSC of 0.716, which is comparable to training from scratch with all target data (DSC: 0.719) and significantly better than full fine-tuning with all data.
- RCA-based selection of the combined best- and worst-5 subjects yielded results similar to real DSC-based selection, indicating RCA's reliability as a proxy for performance prediction.
- Fine-tuning with pseudo-labels introduced noise and degraded performance, showing that pseudo-labeling is not beneficial in this supervised domain adaptation setting.
- The RCA-guided method reduced annotation burden by focusing on only 10 subjects (10% of target data), achieving state-of-the-art performance with minimal labeling effort.
- The approach eliminated the need for iterative active learning, enabling a one-step selection and fine-tuning pipeline that is faster and more efficient than existing methods.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.