[Paper Review] Dynamics of cardiac re-entry in micro-CT and serial histological sections based models of mammalian hearts
This study uses high-resolution micro-CT and serial histological data to simulate cardiac re-entry in rat pulmonary vein walls and sheep atria, demonstrating that geometry and transmural fiber anisotropy—particularly a ~90° fiber rotation—can induce and stabilize re-entry without electrophysiological inhomogeneities. The key finding is that a plane wave can be converted into a pinned re-entry by the combined effect of wall thickness fluctuations and anisotropic conduction, revealing a geometric mechanism for micro-anatomic re-entry initiation.
Cardiac re-entry regime of self-organised abnormal synchronisation underlie dangerous arrhythmias and fatal fibrillation. Recent advances in the theory of dissipative vortices, experimental studies, and anatomically realistic computer simulations, elucidated the role of cardiac re-entry interaction with fine anatomical features in the heart, and anatomy induced drift. The fact that anatomy and structural anisotropy of the heart is consistent within a species suggested its possible functional effect on spontaneous drift of cardiac re-entry. A comparative study of the anatomy induced drift could be used in order to predict evolution of atrial arrhythmia, and improve low-voltage defibrillation protocols and ablation strategies. Here, in micro-CT based model of rat pulmonary vein wall, and in sheep atria models based on high resolution serial histological sections, we demonstrate effects of heart geometry and anisotropy on cardiac re-entry anatomy induced drift, its pinning to fluctuations of thickness in the layer. The data sets of sheep atria and rat pulmonary vein wall are incorporated into the BeatBox High Performance Computing simulation environment. Re-entry is initiated at prescribed locations in the spatially homogeneous mono-domain models of cardiac tissue. Excitation is described by FitzHugh-Nagumo kinetics. In the in-silico models, isotropic and anisotropic conduction show specific anatomy effects and the interplay between anatomy and anisotropy of the heart. The main objectives are to demonstrate the functional role of the species hearts geometry and anisotropy on cardiac re-entry anatomy induced drift. In case of the rat pulmonary vein wall with ~90 degree transmural fibre rotation, it is shown that the joint effect of the PV wall geometry and anisotropy turns a plane excitation wave into a re-entry pinned to a small fluctuation of thickness in the wall.
Motivation & Objective
- To investigate the functional role of cardiac geometry and anisotropy in anatomy-induced drift of re-entrant excitation waves.
- To assess whether intrinsic structural features such as fiber rotation and wall thickness variations can initiate and stabilize re-entry without electrophysiological heterogeneities.
- To evaluate the impact of species-specific anatomical features—such as pectinate muscles and Bachman’s bundle—on re-entry pinning and stability.
- To demonstrate that high-resolution anatomical data can be directly integrated into HPC simulations for realistic in-silico modeling of cardiac arrhythmias.
- To explore the differential endocardial and epicardial manifestations of re-entry due to 3D excitation patterns in thin-walled tissues like the pulmonary vein.
Proposed method
- High-resolution micro-CT and serial histological section data sets from rat pulmonary vein walls and sheep atria were used to reconstruct detailed 3D anatomical models.
- The BeatBox High Performance Computing environment was used to perform anatomically and biophysically realistic simulations of cardiac electrophysiology.
- Excitation propagation was modeled using the simplified FitzHugh-Nagumo equations on isotropic and anisotropic conduction tensors derived from fiber orientation data.
- A diffusivity tensor based on transmural fiber directions was incorporated to simulate anisotropic conduction, particularly in the rat pulmonary vein wall.
- Re-entry was initiated via a single plane wave stimulus, and dynamics were analyzed for drift, pinning, and chirality effects.
- Simulations compared isotropic vs. anisotropic conduction to isolate the role of fiber direction and tissue geometry in re-entry stability and morphology.
Experimental results
Research questions
- RQ1Can geometry and anisotropy alone, without electrophysiological inhomogeneities, initiate and stabilize cardiac re-entry in mammalian hearts?
- RQ2How does a ~90° transmural fiber rotation in the rat pulmonary vein wall influence the transition from a plane wave to a pinned re-entrant circuit?
- RQ3To what extent do fine anatomical features such as wall thickness fluctuations or pectinate muscles act as pinning sites for re-entrant wavefronts?
- RQ4How do endocardial and epicardial excitation patterns differ in 3D for the same re-entrant circuit due to anisotropic conduction?
- RQ5Can species-specific anatomical features like Bachman’s bundle in sheep atria sustain stable re-entry through anatomy-induced drift?
Key findings
- In the rat pulmonary vein wall with ~90° transmural fiber rotation, the joint effect of geometry and anisotropy can transform a plane excitation wave into a stable, thickness-pinned re-entry without any electrophysiological inhomogeneities.
- Re-entry with different chirality exhibited qualitatively distinct stabilization patterns, indicating that wavefront handedness influences stability in complex anatomical environments.
- The same micro-anatomic re-entry was observed to appear as a 'figure eight' pattern on the endocardium but as two focal sources on the epicardium, highlighting significant 3D excitation pattern differences.
- Pectinate muscles and Bachman’s bundle in sheep atria models were identified as potential pinning sites for positive filament tension re-entry, sustaining the arrhythmia.
- Anisotropic conduction enhanced excitation propagation along specific axes (e.g., vertical y-axis on epicardium, horizontal x-axis on endocardium), but these effects were shown to be artificial when based solely on fiber direction without physiological validation.
- The study confirms that high-resolution anatomical and myofiber data can be directly used in HPC simulations to reveal previously unobserved mechanisms of re-entry initiation and stabilization.