Skip to main content
QUICK REVIEW

[Paper Review] Efficient identification of myocardial material parameters and the stress-free reference configuration for patient-specific human heart models

Laura Marx, Justyna A. Niestrawska|arXiv (Cornell University)|Jan 12, 2021
Elasticity and Material ModelingEngineering68 references5 citations
TL;DR

This paper presents a novel, automated algorithm for efficiently identifying patient-specific myocardial material parameters and the stress-free reference configuration in human heart models using only clinical MRI data and a single end-diastolic pressure-volume data point. The method employs a fast, robust optimization framework that fits a model function to the end-diastolic pressure-volume relation, achieving high accuracy with minimal input and enabling clinical translation of personalized cardiac simulations.

ABSTRACT

Image-based computational models of the heart represent a powerful tool to shed new light on the mechanisms underlying physiological and pathological conditions in cardiac function and to improve diagnosis and therapy planning. However, in order to enable the clinical translation of such models, it is crucial to develop personalized models that are able to reproduce the physiological reality of a given patient. There have been numerous contributions in experimental and computational biomechanics to characterize the passive behavior of the myocardium. However, most of these studies suffer from severe limitations and are not applicable to high-resolution geometries. In this work, we present a novel methodology to perform an automated identification of in vivo properties of passive cardiac biomechanics. The highly-efficient algorithm fits material parameters against the shape of a patient-specific approximation of the end-diastolic pressure-volume relation (EDPVR). Simultaneously, a stress-free reference configuration is generated, where a novel fail-safe feature to improve convergence and robustness is implemented. Only clinical image data or previously generated meshes at one time point during diastole and one measured data point of the EDPVR are required as an input. The proposed method can be straightforwardly coupled to existing finite element (FE) software packages and is applicable to different constitutive laws and FE formulations. Sensitivity analysis demonstrates that the algorithm is robust with respect to initial input parameters.

Motivation & Objective

  • To enable clinical translation of personalized cardiac simulations by overcoming limitations in current methods for identifying passive myocardial material properties.
  • To develop an automated, robust algorithm that requires only minimal in-vivo data—specifically, one end-diastolic pressure-volume data point and a single time-point mesh or MRI scan.
  • To simultaneously estimate both the myocardial material parameters and the stress-free reference configuration in a single optimization framework.
  • To improve convergence and robustness through a novel fail-safe mechanism in the optimization process.
  • To ensure compatibility with various constitutive laws and finite element software packages for broad clinical applicability.

Proposed method

  • The method uses a model function to fit the end-diastolic pressure-volume relation (EDPVR) derived from clinical imaging data, with the goal of minimizing the difference between simulated and target EDPVR.
  • A novel fail-safe feature is implemented to enhance convergence and robustness during the optimization of material parameters and reference configuration.
  • The algorithm simultaneously identifies material parameters and the stress-free reference configuration by minimizing a combined error metric over the EDPVR curve.
  • Five different model functions are tested: energy-Demiray, exp-function, exp-squared, power-function, and Laplace-law, each designed to represent different constitutive behaviors.
  • The method is formulated such that the simulated EDPVR passes through zero pressure at the stress-free reference volume, ensuring physical consistency.
  • The approach is compatible with various finite element formulations and constitutive laws, enabling integration into existing cardiac simulation pipelines.

Experimental results

Research questions

  • RQ1Can a single in-vivo pressure-volume data point and a single time-point geometry from MRI be sufficient to identify patient-specific myocardial material parameters and the stress-free reference configuration?
  • RQ2How can the convergence and robustness of the parameter identification process be improved in the absence of extensive experimental data?
  • RQ3Which model function provides the most accurate and efficient fit to the end-diastolic pressure-volume relation across diverse patient geometries?
  • RQ4To what extent can the method be generalized across different constitutive laws and finite element software platforms?
  • RQ5How sensitive is the algorithm to initial parameter guesses, and does it maintain accuracy under realistic clinical data uncertainty?

Key findings

  • The energy-Demiray and exp-function model functions demonstrated the fastest convergence and highest fitting accuracy, with relative area errors below 8% for both test cases.
  • For case 06-CoA, the exp-squared and power-function models showed slower convergence, while the Laplace-law model had the highest area error (8.40%) and deflection error.
  • The energy-Demiray and exp-function models achieved a relative volume error of 0.11% and 0.13% for case 06-CoA, respectively, indicating excellent fit to the target Klotz curve.
  • The method showed robustness to initial parameter values, as confirmed by sensitivity analysis, supporting its reliability in clinical settings.
  • The Laplace-law model provided the closest fit in the low-pressure range but diverged significantly at higher pressures, making it less suitable overall despite its physical intuition.
  • The algorithm successfully generated a stress-free reference configuration that was consistent with the simulated EDPVR, validating the dual estimation of parameters and reference state.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.